Robot-musculoskeletal dynamic biomechanical model in robot-assisted diaphyseal fracture reduction

被引:16
作者
Li, Changsheng [1 ]
Wang, Tianmiao [1 ]
Hu, Lei [1 ]
Zhang, Lihai [2 ]
Zhao, Yanpeng [2 ]
Du, Hailong [2 ]
Wang, Lifeng [1 ]
Tang, Peifu [2 ]
机构
[1] Beihang Univ, Sch Mech Engn & Automat, Beijing 100191, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Dept Orthopaed, Beijing 100853, Peoples R China
关键词
Robot-assisted diaphyseal fracture reduction; musculoskeletal system; biomechanical model; simulation analysis; SYSTEM;
D O I
10.3233/BME-151324
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A number of issues that exist in common fracture reduction surgeries can be mitigated by robot-assisted fracture reduction. However, the safety of patients and the performance of the robot, which are closely related to the muscle forces, are important indexes that restrict the development of robots. Though researchers have done a great deal of work on the biomechanics of the musculoskeletal system, the dynamics of the musculoskeletal system, particularly the aspects related to the function of the robot, is not well understood. For this reason, we represent the complex biological system by establishing a dynamic biomechanical model based on the Hill muscle model and the Kane method for the robot that we have developed and the musculoskeletal system. We analyzed the relationship between the motion and force of the bone fragments and the robot during a simulation of a robot-assisted fracture reduction. The influence of the muscle force on the robot system was predicted and managed. The simulation results provide a basis for a fracture reduction path plan that ensures patient safety and a useful reference for the mechanical design of the robot.
引用
收藏
页码:S365 / S374
页数:10
相关论文
共 25 条
  • [1] A Model of the Lower Limb for Analysis of Human Movement
    Arnold, Edith M.
    Ward, Samuel R.
    Lieber, Richard L.
    Delp, Scott L.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (02) : 269 - 279
  • [2] AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES
    DELP, SL
    LOAN, JP
    HOY, MG
    ZAJAC, FE
    TOPP, EL
    ROSEN, JM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (08) : 757 - 767
  • [3] Advancing computer-assisted orthopaedic surgery using a hexapod device for closed diaphyseal fracture reduction
    Du, Hailong
    Hu, Lei
    Li, Changsheng
    Wang, Tianmiao
    Zhao, Lu
    Li, Yang
    Mao, Zhi
    Liu, Daohong
    Zhang, Lining
    He, Chunqing
    Zhang, Licheng
    Hou, Hongping
    Zhang, Lihai
    Tang, Peifu
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (03) : 348 - 359
  • [4] Fe Z., 1989, CRITICAL REV BIOMEDI, V17, P359
  • [5] Grand challenge competition to predict in vivo knee loads
    Fregly, Benjamin J.
    Besier, Thor F.
    Lloyd, David G.
    Delp, Scott L.
    Banks, Scott A.
    Pandy, Marcus G.
    D'Lima, Darryl D.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (04) : 503 - 513
  • [6] Reduction of femoral shaft fractures in vitro by a new developed reduction robot system 'RepoRobo'
    Füchtmeier, B
    Egersdoerfer, S
    Mai, R
    Hente, R
    Dragoi, D
    Monkman, G
    Nerlich, M
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 : 113 - 119
  • [7] The three-dimensional determination of internal loads in the lower extremity
    Glitsch, U
    Baumann, W
    [J]. JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) : 1123 - 1131
  • [8] Forces and torques during fracture reduction:: Intraoperative measurements in the femur
    Gösling, T
    Westphal, R
    Faülstich, J
    Sommer, K
    Wahl, F
    Krettek, C
    Hufner, T
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (03) : 333 - 338
  • [9] Robot-assisted fracture reduction: A preliminary study in the femur shaft
    Gosling, T
    Westphal, R
    Hufner, T
    Faulstich, J
    Kfuri, M
    Wahl, F
    Krettek, C
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (01) : 115 - 120
  • [10] Design of a parallel long bone fracture reduction robot with planning treatment tool
    Graham, A. E.
    Xie, S. Q.
    Aw, K. C.
    Xu, W. L.
    Mukherjee, S.
    [J]. 2006 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-12, 2006, : 1255 - 1260