Transvenous embolization of traumatic carotid cavernous fistula with mechanical detachable coils

被引:7
|
作者
Irie, K [1 ]
Fujiwara, T [1 ]
Kuyama, H [1 ]
Nagao, S [1 ]
Ohkawa, M [1 ]
机构
[1] KAGAWA MED SCH,DEPT RADIOL,MIKI,KAGAWA 76107,JAPAN
关键词
traumatic carotid cavernous fistula; transvenous embolization; mechanical detachable coils;
D O I
10.1055/s-2008-1052211
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
An attempt at transarterial balloon embolization of a traumatic carotid cavernous fistula was made but the carotid artery rent was too small for this approach. The patient was then treated by antegrade embolization through a superior ophthalmic vein using mechanical detachable coils. Successful obliteration of the fistula was achieved with preservation of the carotid artery. Transvenous embolization is an alternative technique to treat patients with traumatic carotid cavernous fistulas, especially when a transarterial approach has failed.
引用
收藏
页码:28 / 30
页数:3
相关论文
共 50 条
  • [1] Transvenous treatment of a complex cavernous sinus dural arteriovenous fistula secondary to balloon embolization of a traumatic carotid-cavernous fistula
    Hai Jian
    Chen Zuo-quan
    Deng Dong-feng
    Pan Qing-gang
    Ling Feng
    CHINESE MEDICAL JOURNAL, 2006, 119 (21) : 1846 - 1848
  • [3] Transvenous detachable coil embolization of direct & high-flow carotid-cavernous fistula - Alternative of transarterial detachable balloon embolization
    Nishizawa, T
    Terada, K
    Matsuyama, N
    INTERVENTIONAL NEURORADIOLOGY, 2000, 6 : 117 - 124
  • [4] Transarterial detachable coil embolization combined with ipsilateral intermittent carotid oppression for traumatic carotid-cavernous fistula with small fistula
    Huang, Qing
    Zhang, Hongbing
    Wang, Gang
    Yang, Jun
    Hu, Yanlong
    Liu, Jianxin
    CHINESE JOURNAL OF TRAUMATOLOGY, 2015, 18 (02) : 98 - 101
  • [5] Transarterial detachable coil embolization combined with ipsilateral intermittent carotid oppression for traumatic carotid-cavernous fistula with small fistula
    Huang Qing
    Zhang Hongbing
    Wang Gang
    Yang Jun
    Hu Yanlong
    Liu Jianxin
    中华创伤杂志英文版, 2015, 18 (02) : 98 - 101
  • [6] Cranial nerve palsy following transvenous embolization for a cavernous sinus dural arteriovenous fistula: association with the volume and location of detachable coils
    Nishino, Kazuhiko
    Ito, Yasushi
    Hasegawa, Hitoshi
    Kikuchi, Bumpei
    Shimbo, Junsuke
    Kitazawa, Keiko
    Fujii, Yukihiko
    JOURNAL OF NEUROSURGERY, 2008, 109 (02) : 208 - 214
  • [7] A venographic operational classification for transvenous embolization of dural carotid-cavernous fistula
    Simon C. H. Yu
    K. M. Cheng
    Patrick H. T. Tam
    George K. C. Wong
    C. M. Chan
    Y. L. Cheung
    W. S. Poon
    Neuroradiology, 2011, 53 : 993 - 999
  • [8] Transvenous embolization of a carotid-cavernous fistula via the inferior ophthalmic vein
    Liang, Buqing
    Moskalik, Anzhela D.
    Taylor, Maritza N.
    Waldau, Ben
    JOURNAL OF NEUROSURGERY-CASE LESSONS, 2024, 8 (07):
  • [9] A venographic operational classification for transvenous embolization of dural carotid-cavernous fistula
    Yu, Simon C. H.
    Cheng, K. M.
    Tam, Patrick H. T.
    Wong, George K. C.
    Chan, C. M.
    Cheung, Y. L.
    Poon, W. S.
    NEURORADIOLOGY, 2011, 53 (12) : 993 - 999
  • [10] Successful treatment using detachable coils for traumatic carotid cavernous fistula as a complication of transsphenoidal surgery for a pituitary adenoma: a case report
    Kobayashi, N
    Abe, T
    Furuya, H
    Dohi, K
    Shimazu, M
    Sasaki, K
    Izumiyama, H
    Matsumoto, K
    Ohki, S
    Nemoto, S
    NEUROLOGICAL SURGERY, 2000, 28 (02): : 167 - 171