Absolute Measurement of Effective Atomic Number and Electron Density using Dual-Energy Computed Tomography images

被引:0
作者
Kim, Dae-Hong [1 ]
Kim, Hee-Joung [1 ]
Lee, Chang-Lae [1 ]
Cho, Hyo-Min [1 ]
Park, Hye-Suk [1 ]
Lee, Seung-Wan [1 ]
Choi, Yu-Na [1 ]
Kim, Ye-Seul [1 ]
Park, Su-Jin [1 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju, South Korea
来源
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING | 2012年 / 8313卷
关键词
Dual-energy computed tomography; effective atomic number; electron density; X-RAY CT; TISSUE SEGMENTATION; PEDIATRIC CT; QUALITY;
D O I
10.1117/12.910856
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The dual-energy computed tomography (CT) techniques can be adopted to separate the materials having similar Houndsfield Unit (HU) value such as tissues. In the technique, CT image values can be described as effective atomic number and electron density using the dual-energy equation. In this work, we measured effective atomic number and electron density using dual-energy CT images and assessed the image quality in vascular application. For the effective atomic number assessment, the measurements of a Polymethyl methacrylate (PMMA) and water demonstrated small discrepancies of 3.28 % and 5.56 %, respectively. For electron density measurement, the experimental errors of PMMA and water were 7.83 % and 4.00 %, respectively. The trend obtained when comparing the HU values and absolute values such as effective atomic number and electron density demonstrates that the CNR of the HU values is higher than that of the absolute values such as effective atomic number and electron density. With contrast media having low concentration, it is remarkable that the effective atomic number image occasionally has higher CNR values than the HU images. In this study, small discrepancies between the experimental values and known values were obtained. The CNR values provided meaningful results for the absolute measurements in a dual-energy CT technique.
引用
收藏
页数:10
相关论文
共 14 条
  • [1] Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations
    Bazalova, Magdalena
    Carrier, Jean-Francois
    Beaulieu, Luc
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) : 2439 - 2456
  • [2] Tissue segmentation in Monte Carlo treatment planning: A simulation study using dual-energy CT images
    Bazatova, Magdatena
    Carrier, Jean-Francois
    Beautieu, Luc
    Verhaegen, Frank
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) : 93 - 98
  • [3] Dose reduction in pediatric CT: A rational approach
    Boone, JM
    Geraghty, EM
    Seibert, JA
    Wootton-Gorges, SL
    [J]. RADIOLOGY, 2003, 228 (02) : 352 - 360
  • [4] Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography
    Deng, K.
    Liu, C.
    Ma, R.
    Sun, C.
    Wang, X. -m.
    Ma, Z. -t.
    Sun, X. -l.
    [J]. CLINICAL RADIOLOGY, 2009, 64 (05) : 534 - 541
  • [5] Material differentiation by dual energy CT: initial experience
    Johnson, Thorsten R. C.
    Krauss, Bernhard
    Sedlmair, Martin
    Grasruck, Michael
    Bruder, Herbert
    Morhard, Dominik
    Fink, Christian
    Weckbach, Sabine
    Lenhard, Miriam
    Schmidt, Bernhard
    Flohr, Thomas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (06) : 1510 - 1517
  • [6] Quantitative imaging of element composition and mass fraction using dual-energy CT: Three-material decomposition
    Liu, Xin
    Yu, Lifeng
    Primak, Andrew N.
    McCollough, Cynthia H.
    [J]. MEDICAL PHYSICS, 2009, 36 (05) : 1602 - 1609
  • [7] Dual-energy X-ray CT with CdTe array and its extension
    Ohno, Y
    Torikoshi, M
    Tsunoo, T
    Hyodo, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) : 72 - 77
  • [8] Radiation dose and image quality in pediatric CT: Effect of technical factors and phantom size and shape
    Siegel, MJ
    Schmidt, B
    Bradley, D
    Suess, C
    Hildebolt, C
    [J]. RADIOLOGY, 2004, 233 (02) : 515 - 522
  • [9] Electron density measurement with dual-energy x-ray CT using synchrotron radiation
    Torikoshi, M
    Tsunoo, T
    Sasaki, M
    Endo, M
    Noda, Y
    Ohno, Y
    Kohno, T
    Hyodo, K
    Uesugi, K
    Yagi, N
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (05) : 673 - 685
  • [10] Tsunoo T, 2004, IEEE NUCL SCI CONF R, P3764