The current state of bearing surfaces in total hip replacement

被引:56
作者
Rajpura, A. [1 ]
Kendoff, D. [1 ]
Board, T. N. [1 ]
机构
[1] Wrightington Hosp, Ctr Hip Surg, Appley Bridge WN6 9EP, Wigan, England
关键词
METAL-ON-METAL; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; RANDOMIZED CONTROLLED-TRIAL; FUNCTIONAL BIOLOGICAL-ACTIVITY; ALUMINA CERAMIC BEARINGS; IN-VIVO DETERMINATION; OXINIUM FEMORAL-HEAD; TNF-ALPHA PRODUCTION; LONG-TERM WEAR;
D O I
10.1302/0301-620X.96B2.31920
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual's functional demands.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 172 条
  • [121] Pseudotumours associated with metal-onmetal hip resurfacings
    Pandit, H.
    Glyn-Jones, S.
    McLardy-Smith, P.
    Gundle, R.
    Whitwell, D.
    Gibbons, C. L. M.
    Ostlere, S.
    Athanasou, N.
    Gill, H. S.
    Murray, D. W.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (07): : 847 - 851
  • [122] Primary Cementless Total Hip Arthroplasty with an Alumina Ceramic-on-Ceramic Bearing Results After a Minimum of Twenty Years of Follow-up
    Petsatodis, George E.
    Papadopoulos, Pericles P.
    Papavasiliou, Kyriakos A.
    Hatzokos, Ippokratis G.
    Agathangelidis, Filon G.
    Christodoulou, Anastasios G.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (03) : 639 - 644
  • [123] Gamma sterilization of UHMWPE articular implants: An analysis of the oxidation problem
    Premnath, V
    Harris, WH
    Jasty, M
    Merrill, EW
    [J]. BIOMATERIALS, 1996, 17 (18) : 1741 - 1753
  • [124] Cementless Metasul Metal-On-Metal Total Hip Arthroplasties at 13 Years
    Randelli, Filippo
    Banci, Lorenzo
    D'Anna, Alessandro
    Visentin, Ornella
    Randelli, Gianni
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (02) : 186 - 192
  • [125] Natural History of Squeaking after Total Hip Arthroplasty
    Restrepo, Camilo
    Matar, Wadih Y.
    Parvizi, Javad
    Rothman, Richard H.
    Hozack, William J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) : 2340 - 2345
  • [126] Comparative Oxidative Stability of α-Tocopherol Blended and Diffused UHMWPEs at 3 Years of Real-Time Aging
    Rowell, Shannon L.
    Oral, Ebru
    Muratoglu, Orhun K.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (05) : 773 - 780
  • [127] Diamond-Like Carbon Coatings Enhance Scratch Resistance of Bearing Surfaces for Use in Joint Arthroplasty: Hard Substrates Outperform Soft
    Roy, Marie E.
    Whiteside, Leo A.
    Katerberg, Brian J.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 89B (02) : 527 - 535
  • [128] Midterm results of metasul metal-on-metal total hip arthroplasty
    Saito, Shu
    Ryu, Junnosuke
    Watanabe, Masahiko
    Ishii, Takao
    Saigo, Kaichiro
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (08) : 1105 - 1110
  • [129] A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene
    Sakoda, H
    Voice, AM
    McEwen, HMJ
    Isaac, GH
    Hardaker, C
    Wroblewski, BM
    Fisher, J
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (08) : 1018 - 1023
  • [130] Salehi A., 2010, Clin. Cases Miner. Bone Metab, V7, P169