The current state of bearing surfaces in total hip replacement

被引:56
作者
Rajpura, A. [1 ]
Kendoff, D. [1 ]
Board, T. N. [1 ]
机构
[1] Wrightington Hosp, Ctr Hip Surg, Appley Bridge WN6 9EP, Wigan, England
关键词
METAL-ON-METAL; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; RANDOMIZED CONTROLLED-TRIAL; FUNCTIONAL BIOLOGICAL-ACTIVITY; ALUMINA CERAMIC BEARINGS; IN-VIVO DETERMINATION; OXINIUM FEMORAL-HEAD; TNF-ALPHA PRODUCTION; LONG-TERM WEAR;
D O I
10.1302/0301-620X.96B2.31920
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual's functional demands.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 172 条
  • [91] History and Systematic Review of Wear and Osteolysis Outcomes for First-generation Highly Crosslinked Polyethylene
    Kurtz, Steven M.
    Gawel, Heather A.
    Patel, Jasmine D.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) : 2262 - 2277
  • [92] Cross-linked versus conventional polyethylene for total hip replacement A META-ANALYSIS OF RANDOMISED CONTROLLED TRIALS
    Kuzyk, P. R. T.
    Saccone, M.
    Sprague, S.
    Simunovic, N.
    Bhandari, M.
    Schemitsch, E. H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05): : 593 - 600
  • [93] Femoral Head Size and Wear of Highly Cross-linked Polyethylene at 5 to 8 Years
    Lachiewicz, Paul F.
    Heckman, Daniel S.
    Soileau, Elizabeth S.
    Mangla, Jimmi
    Martell, John M.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (12) : 3290 - 3296
  • [94] Pre-clinical studies to validate the MITCH PCR™ Cup:: a flexible and anatomically shaped acetabular component with novel bearing characteristics
    Latif, Ahmed M. H.
    Mehats, Aude
    Elcocks, Martyn
    Rushton, Neil
    Field, Richard E.
    Jones, Eric
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (04) : 1729 - 1736
  • [95] Use of vitamin E to protect cross-linked UHMWPE from oxidation
    Lerf, Reto
    Zurbruegg, Daniel
    Delfosse, Daniel
    [J]. BIOMATERIALS, 2010, 31 (13) : 3643 - 3648
  • [96] EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT
    LIVERMORE, J
    ILSTRUP, D
    MORREY, B
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) : 518 - 528
  • [97] Delta Ceramic-on-Alumina Ceramic Articulation in Primary THA Prospective, Randomized FDA-IDE Study and Retrieval Analysis
    Lombardi, Adolph V., Jr.
    Berend, Keith R.
    Seng, Brian E.
    Clarke, Ian C.
    Adams, Joanne B.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) : 367 - 374
  • [98] An in vivo determination of total hip arthroplasty pistoning during activity
    Lombardi, AV
    Mallory, TH
    Dennis, DA
    Komistek, RD
    Fada, RA
    Northcut, EJ
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (06) : 702 - 709
  • [99] Lusty PJ, 2007, J BONE JOINT SURG BR, V89B, P1158, DOI 10.1302/0301-620X.89B9
  • [100] Do First-generation Highly Crosslinked Polyethylenes Oxidize In Vivo?
    MacDonald, Daniel
    Sakona, Ashlyn
    Ianuzzi, Allyson
    Rimnac, Clare M.
    Kurtz, Steven M.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) : 2278 - 2285