Smart Toe® Implant Versus Buried Kirschner Wire for Proximal Interphalangeal Joint Arthrodesis: A Comparative Study

被引:29
作者
Scholl, Alex [1 ]
McCarty, James [2 ]
Scholl, Desiree [3 ]
Mar, Alice [1 ]
机构
[1] St John Hosp & Med Ctr, Detroit, MI USA
[2] Shores Podiatry Associates LLC, Rosewood, MI USA
[3] Maplewood Podiatry, Maplewood, MN USA
关键词
digital fusion; hammer toe; K-wire; phalanx; surgery; HAMMERTOE; DEFORMITY; REPAIR;
D O I
10.1053/j.jfas.2013.02.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The surgical correction of hammer digits offers a variety of surgical treatments ranging from arthroplasty to arthrodesis, with many options for fixation. In the present study, we compared 2 buried implants for arthrodesis of lesser digit deformities: a Smart Toe (R) implant and a buried Kirschner wire. Both implants were placed in a prepared interphalangeal joint, did not violate other digital or metatarsal joints, and were not exposed percutaneously. A retrospective comparative study was performed of 117 digits with either a Smart Toe (R) implant or a buried Kirschner wire, performed from January 1, 2007 to December 31, 2010. Of the 117 digits, 31 were excluded because of a lack of 90-day radiographic follow-up. The average follow-up was 94 to 1130 days. The average patient age was 61.47 (range 43 to 84) years. Of the 86 included digits, 48 were left digits and 38 were right. Of the digits corrected, 54 were second digits, 24 were third digits and 8 were fourth digits. Fifty-eight Smart Toe (R) implants were found (15 with 19-mm straight; 2 with 19-mm angulated; 34 with 16-mm straight; and 7 with 16-mm angulated). Twenty-eight buried Kirschner wires were evaluated. No statistically significant difference was found between the Smart Toe (R) implants and the buried Kirschner wires, including the rate of malunion, nonunion, fracture of internal fixation, and the need for revision surgery. Of the 86 implants, 87.9% of the Smart Toe (R) implants and 85.7% of the buried Kirschner wires were in good position (0 degrees to 10 degrees of transverse angulation on radiographs). Osseous union was achieved in 68.9% of Smart Toe (R) implants and 82.1% of buried Kirschner wires. Fracture of internal fixation occurred in 12 of the Smart Toe (R) implants (20.7%) and 2 of the buried Kirschner wires (7.1%). Most of the fractured internal fixation and malunions or nonunibns were asymptomatic, leading to revision surgery in only 8.6% of the Smart Toe (R) implants and 10.7% of the buried Kirschner wires. Both the Smart Toe (R) implant and the buried Kirschner wire offer a viable choice for internal fixation of an arthrodesis of the digit compared with other studies using other techniques. (C) 2013 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:580 / 583
页数:4
相关论文
共 20 条
[1]  
Augoyard M, 2007, PROXIMAL
[2]   Combined plantar plate and hammertoe repair with flexor digitorum longus tendon transfer for chronic, severe sagittal plane instability of the lesser metatarsophalangeal joints:: Preliminary observations [J].
Bouche, Richard T. ;
Heit, Eric J. .
JOURNAL OF FOOT & ANKLE SURGERY, 2008, 47 (02) :125-137
[3]  
Briggs L., 2004, TECH FOOT ANKLE SURG, V3, P77
[4]   Arthrodesis of the toe joints with an intramedullary cannulated screw for correction of hammertoe deformity [J].
Caterini, R ;
Farsetti, P ;
Tarantino, U ;
Potenza, V ;
Ippolito, E .
FOOT & ANKLE INTERNATIONAL, 2004, 25 (04) :256-261
[5]   Operative repair of the fixed hammertoe deformity [J].
Coughlin, MJ ;
Dorris, J ;
Polk, E .
FOOT & ANKLE INTERNATIONAL, 2000, 21 (02) :94-104
[6]  
Creighton R E, 1995, J Foot Ankle Surg, V34, P567
[7]   New Intramedullary Implant for Proximal Interphalangeal Joint Arthrodesis [J].
Cuttica, Daniel J. ;
DeCarbo, William ;
Smith, W. Bret ;
Berlet, Gregory C. .
TECHNIQUES IN FOOT AND ANKLE SURGERY, 2008, 7 (03) :203-206
[8]  
Edwards William H B, 2002, Foot Ankle Clin, V7, P43, DOI 10.1016/S1083-7515(02)00002-5
[9]   Radiographic Analysis of Proximal Interphalangeal Joint Arthrodesis With an Intramedullary Fusion Device for Lesser Toe Deformities [J].
Ellington, J. Kent ;
Anderson, Robert B. ;
Davis, W. Hodges ;
Cohen, Bruce E. ;
Jones, Carroll P. .
FOOT & ANKLE INTERNATIONAL, 2010, 31 (05) :372-376
[10]   Smart intramedullary rod for correction of pediatric bone deformity - A preliminary study [J].
Firoozbakhsh, K ;
Moneim, MS ;
Yi, IS ;
Umeda, Y ;
Theele, D ;
Shahinpoor, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (424) :194-201