Impact of Implantoplasty on Strength of the Implant-Abutment Complex

被引:47
作者
Chan, Hsun-Liang [1 ]
Oh, Won-Suck [2 ]
Ong, Hwei Sze [1 ]
Fu, Jia-Hui [3 ]
Steigmann, Marius
Sierraalta, Marianella [2 ]
Wang, Hom-Lay [1 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Dent, Dept Biol & Mat Sci, Div Prosthodont, Ann Arbor, MI 48109 USA
[3] Natl Univ Singapore, Discipline Periodont, Fac Dent, Singapore 117548, Singapore
关键词
bending strength; ductile fracture; implantoplasty; peri-implantitis; rough surface; SMALL-DIAMETER IMPLANTS; 3-YEAR CLINICAL-TRIAL; SHAPED ORAL IMPLANTS; PERI-IMPLANTITIS; RESECTIVE SURGERY; SCREW; THERAPY; RESTORATION; DISEASES;
D O I
10.11607/jomi.3227
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Implantoplasty, a procedure that is done to smooth contaminated implant surfaces, has been used in the treatment of peri-implantitis. It reduces the implant diameter, which might compromise the implant's strength. This in vitro study was designed to evaluate the effect of implantoplasty on implant strength. Materials and Methods: Thirty-two tapered implants were used; half were 3.75 mm in diameter (narrow) and the other half were 4.7 mm in diameter (wide). All implants were connected to 20-degree angled abutments. The apical half of each implant was embedded in acrylic resin. Eight 3.75-mm-and eight 4.7-mm-diameter implants were randomly assigned to receive implantoplasty. The remaining implants did not receive implantoplasty (control group). Implantoplasty was performed with a series of diamond and polishing burs. The specimens were then loaded 30 degrees off-axis in a universal testing machine until fracture failure occurred. Bending and fracture strength values were recorded and analyzed statistically (alpha = .05). The fractured surfaces were evaluated under a scanning electron microscope. Results: All narrow implants failed by fracture at the implant platform. The mean bending strength of narrow implants was statistically significantly reduced by implantoplasty (511.4 +/- 55.9 N versus 613.9 +/- 42.8 N). Implantoplasty did not affect the strength of wide implants; fracture failures occurred at the abutment screw. The fracture mode was ductile and the crack growth was oblique in direction, indicating complex stress distribution and concentration under loading. Conclusion: Within the limits of this study, implantoplasty appeared to weaken the strength of narrower implants. Therefore, this procedure should be performed with caution on narrower, freestanding implants that are subject to greater occlusal force (eg, posterior regions). Validation of these results is needed for different implant systems.
引用
收藏
页码:1530 / 1535
页数:6
相关论文
共 23 条
[1]   Porcelain Fracture Resistance of Screw-Retained, Cement-Retained, and Screw-Cement-Retained Implant-Supported Metal Ceramic Posterior Crowns [J].
Al-Omari, Wael M. ;
Shadid, Rola ;
Abu-Naba'a, Layla ;
El Masoud, Bilal .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (04) :263-273
[2]   Managing Peri-Implant Bone Loss: Current Understanding [J].
Aljateeli, Manar ;
Fu, Jia-Hui ;
Wang, Hom-Lay .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 :e109-e118
[3]   Effect of microthread presence and restoration design (screw versus cemented) in dental implant reliability and failure modes [J].
Almeida, Erika O. ;
Freitas Junior, Amilcar C. ;
Bonfante, Estevam A. ;
Rocha, Eduardo Passos ;
Silva, Nelson R. F. A. ;
Coelho, Paulo G. .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (02) :191-196
[4]   Surgical treatment of peri-implantitis [J].
Claffey, Noel ;
Clarke, Emily ;
Polyzois, Ioannis ;
Renvert, Stefan .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 :316-332
[5]   Immediate Restoration of Small-Diameter Implants in Cases of Partial Posterior Edentulism: A 4-Year Case Series [J].
Degidi, Marco ;
Nardi, Diego ;
Piattelli, Adriano .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (06) :1006-1012
[6]   Effect of Implant-Abutment Connection Design on Load Bearing Capacity and Failure Mode of Implants [J].
Dittmer, Stephanie ;
Dittmer, Marc Philipp ;
Kohorst, Philipp ;
Jendras, Michael ;
Borchers, Lothar ;
Stiesch, Meike .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (07) :510-516
[7]  
Esposito M, 2008, EUR J ORAL IMPLANTOL, V1, P111
[8]   Osseointegrated Implant Fracture: Causes and Treatment [J].
Gealh, Walter Cristiano ;
Mazzo, Valeria ;
Barbi, Francisco ;
Camarini, Edevaldo Tadeu .
JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (04) :499-503
[9]   Peri-implant diseases: diagnosis and risk indicators [J].
Heitz-Mayfield, Lisa J. A. .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 :292-304
[10]  
Hsu YT, 2012, INT J ORAL MAX IMPL, V27, P894