A correlation-based continuous window-shift technique to reduce the peak-locking effect in digital PIV image evaluation

被引:126
作者
Gui, L [1 ]
Wereley, ST [1 ]
机构
[1] Purdue Univ, W Lafayette, IN 47907 USA
关键词
D O I
10.1007/s00348-001-0396-1
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper the peak-locking phenomenon is investigated in the evaluation of digital PIV recordings by using a correlation-based interrogation algorithm with a discrete window shift and a correlation-based tracking algorithm. Statistical analyses indicate that nonuniformly distributed bias errors are the main cause of the peak-locking effect, and the amplitude variation of the random error is also an important source of the peak locking. Simulations and experimental examples demonstrate that very strong peak-locking effects exist for the correlation-based interrogation algorithm with discrete window shift in the cases of large particle images, small interrogation windows, and very small particle images. Very strong peak-locking effects are also observed for the correlation-based tracking algorithm when the particle images are overexposed, binarized, or very small. These strong peak-locking effects can be avoided without loss of evaluation accuracy by using a continuous window-shift technique in combination with the correlation-based interrogation algorithm.
引用
收藏
页码:506 / 517
页数:12
相关论文
共 30 条
[1]  
ADRIAN RJ, 1991, ANNU REV FLUID MECH, V23, P261, DOI 10.1146/annurev.fluid.23.1.261
[2]  
CENEDESE A, 1990, EXP FLUIDS, V8, P273
[3]  
Fei R., 1999, Machine Graphics & Vision, V8, P571
[4]   Low cost, high resolution DPIV for measurement of turbulent fluid flow [J].
Fincham, AM ;
Spedding, GR .
EXPERIMENTS IN FLUIDS, 1997, 23 (06) :449-462
[5]   A digital mask technique for reducing the bias error of the correlation-based PIV interrogation algorithm [J].
Gui, L ;
Merzkirch, W ;
Fei, R .
EXPERIMENTS IN FLUIDS, 2000, 29 (01) :30-35
[6]   Generating arbitrarily sized interrogation windows for correlation-based analysis of particle image velocimetry recordings [J].
Gui, L ;
Merzkirch, W .
EXPERIMENTS IN FLUIDS, 1998, 24 (01) :66-69
[7]   A comparative study of the MQD method and several correlation-based PIV evaluation algorithms [J].
Gui L. ;
Merzkirch W. .
Experiments in Fluids, 2000, Springer Verlag (28) :36-44
[8]   Biases of PIV measurement of turbulent flow and the masked correlation-based interrogation algorithm [J].
Gui, L ;
Longo, J ;
Stern, F .
EXPERIMENTS IN FLUIDS, 2001, 30 (01) :27-35
[9]  
HECKMANN W, 1994, C485021 CIT U LOND
[10]  
HUANG HT, 1993, EXP FLUIDS, V15, P168, DOI 10.1007/BF00189883