Speciation analysis of arsenic compounds by capillary electrophoresis on-line coupled with inductively coupled plasma mass spectrometry using a novel interface

被引:59
作者
Liu, Lihong [1 ]
He, Bin [1 ]
Yun, Zhaojun [1 ]
Sun, Jing [1 ]
Jiang, Guibin [1 ]
机构
[1] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
关键词
Arsenic speciation; Capillary electrophoresis; Inductively coupled plasma mass spectrometry; Simple and high efficient interface; PERFORMANCE LIQUID-CHROMATOGRAPHY; ZONE-ELECTROPHORESIS; ROXARSONE; SAMPLES; SELENIUM; FISH; MS;
D O I
10.1016/j.chroma.2013.07.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a capillary electrophoresis (CE) coupled with inductively coupled plasma mass spectrometer (ICP-MS) system was developed for the simultaneous determination of ten arsenic compounds including arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, arsenocholine, 3-nitro-4-hydroxyphenylarsonic acid, o-Arsanilic acid, p-ureidophenylarsonic acid, and 4-nitrophenylarsonic acid. The CE-ICP-MS system was hyphenated by a novel and high efficient interface which was directly used as the nebulizer. The separation was achieved on a 100 cm length x 50 mu m ID fused-silica capillary. Analytical conditions such as electrophoretic buffer composition, concentration and pH value, separation voltage, methanol concentration in the sheath flow liquid and sample injection time were optimized. Baseline separation of the ten arsenic species was achieved using an electrophoretic buffer consisting of 12 mM NaH2PO4 and 8 mM HBO3 at pH 9.20 with an applied voltage of +30 kV. The detection limits of the ten arsenic compounds ranged from 0.9 to 3.0 ng As g(-1), corresponding to absolute detection limits in the range of 19-65 fg As and the relative standard deviations (RSD, n = 5) were below 1.5%, 5.7% and 4.8% for migration time, peak height and peak area, respectively. This method was successfully applied to determine various arsenicals in two certified reference materials (TORT-2 and DORM-3) and environmental samples such as ground water samples, herbal plants and chicken meat. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 50 条
[41]   Determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry [J].
Baker, SA ;
Miller-Ihli, NJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (12) :1823-1832
[42]   Selenium speciation analysis using inductively coupled plasma-mass spectrometry [J].
B'Hymer, C ;
Caruso, JA .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (01) :1-20
[43]   A new interface for coupling capillary electrophoresis to inductively coupled plasma spectrometry [J].
Mei, EW ;
Ichihashi, H ;
Yamazaki, S .
CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1997, 18 (08) :1300-1302
[44]   Determination of Lead Species in Algae by Capillary Electrophoresis-Inductively Coupled Plasma-Mass Spectrometry [J].
Li Jing-Xi ;
Sun Cheng-Jun ;
Zheng Li ;
Jiang Feng-Hua ;
Yin Xiao-Fei ;
Chen Jun-Hui ;
Wang Xiao-Ru .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (11) :1659-1664
[45]   On-line determination of arsenic species in seawater by selective hydride generation coupled with inductively coupled plasma-mass spectrometry [J].
Den, SJ ;
Wei, WC ;
Mierzwa, J ;
Yang, MH .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2002, 49 (02) :197-205
[46]   Speciation analysis of inorganic arsenic by magnetic solid phase extraction on-line with inductively coupled mass spectrometry determination [J].
Montoro Leal, P. ;
Vereda Alonso, E. ;
Lopez Guerrero, M. M. ;
Les Cordero, M. T. ;
Cano Pavon, J. M. ;
Garcia de Torres, A. .
TALANTA, 2018, 184 :251-259
[47]   A Study on Arsenic Speciation in Korean Oyster Samples using Ion Chromatography Inductively Coupled Plasma Mass Spectrometry [J].
Nam, Sang-Ho ;
Cui, Sheng ;
Oh, Hae-Joon ;
Min, Hyung-Sik ;
Lee, Joung Hae .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2015, 36 (01) :250-257
[48]   Capillary electrophoresis on-line coupled with atomic fluorescence spectrometry and its application for speciation analysis [J].
Yin, XB ;
Jiang, Y ;
Yan, XP ;
He, XW .
CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2004, 25 (04) :618-621
[49]   Sequential Injection Analysis (SIA) for Arsenic Speciation by Capillary Electrophoresis Hyphenated to Inductively Coupled Plasma Sector Field Mass Spectrometry (CE-ICP-SFMS) [J].
Suarez, Carlos A. ;
Araujo, Georgia C. L. ;
Gine, Maria F. ;
Kakazu, Mauricio H. ;
Sarkis, Jorge E. S. .
SPECTROSCOPY LETTERS, 2009, 42 (6-7) :376-382
[50]   Characterization of interactions between organotin compounds and human serum albumin by capillary electrophoresis coupled with inductively coupled plasma mass spectrometry [J].
Sun, Jing ;
He, Bin ;
Liu, Qian ;
Ruan, Ting ;
Jiang, Guibin .
TALANTA, 2012, 93 :239-244