Modelling of heat transfer in hot strip mill runout table cooling

被引:8
|
作者
Timm, W [1 ]
Weinzierl, K
Leipertz, A
Zieger, H
Zouhar, G
机构
[1] Univ Erlangen Nurnberg, LTT, D-8520 Erlangen, Germany
[2] Siemens ATD, Erlangen, Germany
[3] Dresden Univ Technol, Dresden, Germany
来源
STEEL RESEARCH | 2002年 / 73卷 / 03期
关键词
D O I
10.1002/srin.200200180
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The need for accurate prediction and control of cooling profiles of steel strips on runout tables has led to the development of a mathematical model that is able to predict coiler temperatures under any given condition with an accuracy of +/- 14degreesC as well as calculating the entire temperature profile of a steel strip with sufficient accuracy. Comparisons with online strip temperature data at various locations of the runout table, which were obtained by a new experimental procedure, show that the effect of single cooling headers on the thermal response of a steel strip can be predicted. The model takes into account all relevant thermodynamic effects by means of a statistical approach. Heat transfer to the environment, steel thermophysical properties and phase transformation are modelled using B-splines. Model adaptation is realised by fitting calculated and measured coiler temperatures of approximately 40000 strips with a least square method in order to gain optimal base values for the B-spline functions. During model development special attention was paid to the model's capability of being re-adjustable to a large variety of conditions as well as its local behaviour. Therefore, concepts like temperature-dependent heat transfer coefficients, which are applicable only to one specific plant, have been avoided in favour of a more generalised formulation of the model that helps to gain insight into the physics of the processes involved, i.e. heat transfer of subcooled jet impingement boiling and film boiling. It was found that both cooling water and steel surface temperature have a large influence on heat transfer whereas the influence of strip speed can be neglected.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [31] Strip cooling for the hot strip mill of Preussag Stahl AG
    Esser, F
    Rullmann, D
    Kohler, W
    Salzburger, G
    STAHL UND EISEN, 1998, 118 (06): : 51 - +
  • [32] Online Monitor and Control of Cooling Temperature on Run-out Table of Hot Strip Mill
    Li, Hai-Jun
    Li, Li-Gang
    Li, Yong-Lin
    Wang, Guo-Dong
    STEEL RESEARCH INTERNATIONAL, 2015, 86 (11) : 1225 - 1233
  • [33] Simulation of accelerated strip cooling on the hot rolling mill run-out roller table
    Muhin, U.
    Belskij, S.
    Makarov, E.
    Koynov, T.
    FRATTURA ED INTEGRITA STRUTTURALE, 2016, (37): : 305 - 311
  • [34] Modelling heat transfer during hot rolling of steel strip
    Universidad Autonoma de Nuevo Leon, Nuevo Leon, Mexico
    Modell Simul Mater Sci Eng, 4 (437-453):
  • [35] Modelling heat transfer in work rolls of a continuous hot strip mill.: Part II:: Operating conditions
    Corral, R. L.
    Colas, R.
    Perez, A.
    INTERNATIONAL E-CONFERENCE ON COMPUTER SCIENCE 2005, 2005, 2 : 37 - 41
  • [36] Advanced run-out table cooling technology based on ultra fast cooling and laminar cooling in hot strip mill
    Liu En-yang
    Peng Liang-gui
    Yuan Guo
    Wang Zhao-dong
    Zhang Dian-hua
    Wang Guo-dong
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (05) : 1341 - 1345
  • [37] Advanced run-out table cooling technology based on ultra fast cooling and laminar cooling in hot strip mill
    刘恩洋
    彭良贵
    袁国
    王昭东
    张殿华
    王国栋
    JournalofCentralSouthUniversity, 2012, 19 (05) : 1341 - 1345
  • [38] Advanced run-out table cooling technology based on ultra fast cooling and laminar cooling in hot strip mill
    En-yang Liu
    Liang-gui Peng
    Guo Yuan
    Zhao-dong Wang
    Dian-hua Zhang
    Guo-dong Wang
    Journal of Central South University, 2012, 19 : 1341 - 1345
  • [39] Simulation of Runout Table Cooling
    Guemo, Gilles Guedia
    Prodanovic, Vladan
    Militzer, Matthias
    STEEL RESEARCH INTERNATIONAL, 2019, 90 (04)
  • [40] Modernization of the run-out table cooling control system at Krakatau Steel hot strip mill
    Bujang, F
    Driyono, J
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1997, 94 (7-8): : 901 - 906