Facile room-temperature synthesis of a spherical mesoporous covalent organic framework for ultrasensitive solid-phase microextraction of phenols prior to gas chromatography-tandem mass spectrometry

被引:152
|
作者
Liu, Lu [1 ]
Meng, Wei-Kun [1 ]
Li, Lei [1 ]
Xu, Gui-Ju [1 ]
Wang, Xia [1 ]
Chen, Li-Zong [1 ]
Wang, Ming-Lin [2 ]
Lin, Jin-Ming [3 ]
Zhao, Ru-Song [1 ]
机构
[1] Qilu Univ Technol, Shandong Acad Sci, Key Lab Appl Technol Sophisticated Analyt Instrum, Anal & Test Ctr, Jinan 250014, Shandong, Peoples R China
[2] Shandong Agr Univ, Coll Food Sci & Engn, Tai An 271018, Shandong, Peoples R China
[3] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Covalent organic frameworks; Room temperature; Solid-phase microextraction; Gas chromatography-tandem mass spectrometry; Phenols; FIBER; POLYMER; WATER; NANOSTRUCTURE; CRYSTALLINE; EXTRACTION; POLLUTANTS; CHEMISTRY; REMOVAL;
D O I
10.1016/j.cej.2019.03.148
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
High-performance extraction of polar phenols from aqueous samples is challenging because of their hydrophilicity, extremely low concentration, and complicated matrices. Covalent organic frameworks (COFs) are new types of porous organic materials. In this work, spherical TPB-DMTP-COF was fabricated via a simple room-temperature solution-phase approach. The material exhibited high acid/base stability, remarkable thermostability, high crystallinity, and large surface area of 1560 m(2) g(-1) and thus could be an excellent coating for solid-phase microextraction (SPME) of phenols. This coating provided superior adsorption affinity toward phenols over commercial coatings. TPB-DMTP-coated fiber showed high enhancement factors (EFs, 1741-4265), and EFs increased with the number of chlorine or methyl substituents and high hydrophobicity of phenols. Hence, the strong adsorption affinity could be derived from hydrophobic and steric hindrance effects together with pi-pi affinity, H-bonding, van der Waals forces, and size-matching effect. The proposed approach based on TPB-DMTP-COF-coated fiber and gas chromatography-tandem mass spectrometry achieved low limits of detection (0.0048-0.015 ng L-1), wide linearity (0.05-1000 ng L-1), good precision (< 8.87%), and reproducibility ( < 10.0%). The actual amounts of phenols ranged from 0.6 ng L-1 to 22.7 ng L-1 in underground water and reservoir water. The satisfactory recoveries (81.3-116.3%) for simultaneous analysis of five phenols were obtained. Therefore, TPB-DMTP-COF coating could be an excellent alternative for sensitive analysis of phenols at ultra-trace level in complex samples.
引用
收藏
页码:920 / 927
页数:8
相关论文
empty
未找到相关数据