Analysis of noise in phase contrast MR imaging

被引:65
作者
Andersen, AH [1 ]
Kirsch, JE [1 ]
机构
[1] UNIV KENTUCKY,MAGNET RESONANCE IMAGING & SPECT CTR,DEPT DIAGNOST RADIOL,LEXINGTON,KY 40536
关键词
noise; magnetic; resonance; imaging; flow;
D O I
10.1118/1.597729
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work we analyze the effects of inherent random noise on the detectability of low-contrast vessel structures that possess slow flow. When flow is encoded in more than one direction, the number of independent noise contributions increases in addition to the scan time. In a fast-flow scenario, only the noise contribution from sampling along the direction of flow is of any significance. At slow flow rates, however, it becomes necessary to account for the noise in each encoded Cartesian direction. The degree to which noise affects low-contrast detectability also depends on the method of phase contrast image processing employed. A theoretical analysis of the statistical properties of signal and noise in processed phase contrast magnitude images is presented and verified from experimental MR image data. Results show a progressively increased bias in the processed phase contrast image magnitude at slow flow rates due to contributions from inherent random noise. The amount of this bias increases with the number of physical directions in which flow is encoded and is larger for complex difference processed images than for phase difference processing. Correspondingly, the output signal-to-noise ratio associated with flow is compromised. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:857 / 869
页数:13
相关论文
共 37 条
[1]  
Abramowitz M., 1964, HDB MATH FUNCTIONS
[2]  
ANDERSEN AH, 1993, P SOC MAGN RES MED 1, P709
[3]   MR FLOW IMAGING BY VELOCITY-COMPENSATED UNCOMPENSATED DIFFERENCE IMAGES [J].
AXEL, L ;
MORTON, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :31-34
[4]   RECONSTRUCTIONS OF PHASE-CONTRAST, PHASED-ARRAY MULTICOIL DATA [J].
BERNSTEIN, MA ;
GRGIC, M ;
BROSNAN, TJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :330-334
[5]   COMPARISON OF PHASE-DIFFERENCE AND COMPLEX-DIFFERENCE PROCESSING IN PHASE-CONTRAST MR ANGIOGRAPHY [J].
BERNSTEIN, MA ;
IKEZAKI, Y .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06) :725-729
[6]   IMPROVED DETECTABILITY IN LOW SIGNAL-TO-NOISE RATIO MAGNETIC-RESONANCE IMAGES BY MEANS OF A PHASE-CORRECTED REAL RECONSTRUCTION [J].
BERNSTEIN, MA ;
THOMASSON, DM ;
PERMAN, WH .
MEDICAL PHYSICS, 1989, 16 (05) :813-817
[7]   CONTRAST-TO-NOISE RATIOS IN MAXIMUM INTENSITY PROJECTION IMAGES [J].
BROWN, DG ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :130-137
[8]   A WEIGHTED LEAST-SQUARES METHOD FOR NUCLEAR-MAGNETIC-RESONANCE VELOCITY IMAGING [J].
CAPRIHAN, A ;
ICENOGLE, MV .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) :512-520
[9]   SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS [J].
CONTURO, TE ;
SMITH, GD .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :420-437
[10]  
CONTURO TE, 1992, MAGNET RESON MED, V29, P134