Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

被引:50
作者
Tricarico, Francesco [1 ,2 ]
Hlavacek, Anthony M. [1 ,3 ]
Schoepf, U. Joseph [1 ,3 ,4 ]
Ebersberger, Ullrich [1 ,5 ]
Nance, John W., Jr. [1 ,6 ]
Vliegenthart, Rozemarijn [1 ,7 ]
Cho, Young Jun [1 ,8 ]
Spears, J. Reid [1 ]
Secchi, Francesco [1 ,9 ]
Savino, Giancarlo [2 ]
Marano, Riccardo [2 ]
Schoenberg, Stefan O. [10 ]
Bonomo, Lorenzo [2 ]
Apfaltrer, Paul [1 ,10 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29401 USA
[2] Univ Cattolica Sacro Cuore, Dept Bioimaging & Radiol Sci, A Gemelli Hosp, I-00168 Rome, Italy
[3] Med Univ S Carolina, Childrens Hosp, Div Pediat Cardiol, Charleston, SC 29401 USA
[4] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29401 USA
[5] Heart Ctr Munich Bogenhausen, Dept Cardiol & Intens Care Med, Munich, Germany
[6] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[7] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, Ctr Med Imaging North East Netherlands, Groningen, Netherlands
[8] Konyang Univ, Dept Radiol, Sch Med, Taejon, South Korea
[9] Univ Milan, Sch Med, IRCCS Policlin San Donato, Dept Med & Surg Sci,Radiol Unit, Milan, Italy
[10] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Mannheim, Germany
关键词
Computed tomography; Congenital heart disease; Radiation dose; Iterative image reconstruction; Pediatric imaging; CONGENITAL HEART-DISEASE; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; PEDIATRIC CT; CANCER RISKS; EXPOSURE; INFANTS; ADULTS; CHEST; AGE;
D O I
10.1007/s00330-012-2734-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. aEuro cent Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. aEuro cent Using half traditional radiation dose image quality is higher with iterative reconstruction. aEuro cent Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.
引用
收藏
页码:1306 / 1315
页数:10
相关论文
共 38 条
[1]   Introduction to cardiac imaging in infants and children: Techniques, potential, and role in the imaging work-up of various cardiac malformations and other pediatric heart conditions [J].
Bailliard, Frederique ;
Hughes, Marina L. ;
Taylor, Andrew M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (02) :191-198
[2]   Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease [J].
Ben Saad, Moez ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne ;
Adler, Ghazal ;
Paul, Jean-Francois .
PEDIATRIC RADIOLOGY, 2009, 39 (07) :668-676
[3]   Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience [J].
Bittencourt, Marcio Sommer ;
Schmidt, Bernhard ;
Seltmann, Martin ;
Muschiol, Gerd ;
Ropers, Dieter ;
Daniel, Werner Guenther ;
Achenbach, Stephan .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) :1081-1087
[4]   Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative [J].
Brenner, DJ .
PEDIATRIC RADIOLOGY, 2002, 32 (04) :228-231
[5]   Estimates of the cancer risks from pediatric CT radiation are not theoretical: Comment on "Point/Counterpoint: In x-ray computed tomography, technique factors should be selected appropriate to size. Against the Proposition" [Med. Phys. 28, 1543-1545 (2001)] [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
MEDICAL PHYSICS, 2001, 28 (11) :2387-2388
[6]   Optimization of Radiation Dose Reduction in Cardiac Computed Tomographic Angiography [J].
Entrikin, Daniel W. ;
Leipsic, Jonathon A. ;
Carr, J. Jeffrey .
CARDIOLOGY IN REVIEW, 2011, 19 (04) :163-176
[7]  
Feng ST, 2010, EUR J RADIOL, V76, P19
[8]   Comparison and Usefulness of Cardiac Magnetic Resonance Versus Computed Tomography in Infants Six Months of Age or Younger With Aortic Arch Anomalies Without Deep Sedation or Anesthesia [J].
Fogel, Mark A. ;
Pawlowski, Thomas W. ;
Harris, Matthew A. ;
Whitehead, Kevin K. ;
Keller, Marc S. ;
Wilson, Justine ;
Tipton, Deanna ;
Harris, Christine .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (01) :120-125
[9]   Computed Tomographic Angiography of Infants with Congenital Heart Disease Receiving Extracorporeal Membrane Oxygenation [J].
Friedman, Brad A. ;
Schoepf, U. Joseph ;
Bastarrika, Gorka A. ;
Hlavacek, Anthony M. .
PEDIATRIC CARDIOLOGY, 2009, 30 (08) :1154-1156
[10]   Comparative evaluation of organ and effective doses for paediatric patients with those for adults in chest and abdominal CT examinations [J].
Fujii, K. ;
Aoyama, T. ;
Koyama, S. ;
Kawaura, C. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (956) :657-667