Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model

被引:14
作者
Ernst, Sabrina [1 ]
Stuebinger, Stefan [1 ,2 ]
Schuepbach, Peter [3 ]
Sidler, Michele [1 ]
Klein, Karina [1 ]
Ferguson, Stephen J. [4 ]
von Rechenberg, Brigitte [1 ,2 ]
机构
[1] Univ Zurich, Musculoskeletal Res Unit MRSU, Vetsuisse Fac ZH, Equine Hosp, CH-8057 Zurich, Switzerland
[2] Univ Zurich, Vetsuisse Fac, CABMM, CH-8057 Zurich, Switzerland
[3] Res Lab Microscopy & Histol, Horgen, Switzerland
[4] ETH, Inst Biomech, Zurich, Switzerland
关键词
bone-to-implant contact; dental implants; osseointegration; removal torque test; resonance frequency; SEM backscatter; sheep; surface; ANIMAL-MODELS; TITANIUM; BONE; INTEGRATION;
D O I
10.1111/clr.12411
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to compare two different surfaces of one uniform macro-implant design in order to focus exclusively on the osseointegration properties after 2, 4 and 8 weeks and to discuss the animal model chosen. Material and methods: In six mature sheep, n = 36 implants with a highly crystalline and phosphate-enriched anodized titanium oxide surface (TiU) and n = 36 implants with a hydrophilic, sandblasted, large grit and acid-etched surface (SLA) were placed in the pelvic bone. TiU implants were custom-made to match the SLA implant design. The implant stability and bone-to-implant contact (BIC) were assessed by resonance frequency (ISQ), backscatter scanning electron microscopy (B-SEM), light microscopy (LM), micro-CT and intravital fluorochrome staining. Biomechanical removal torque testing was performed. Results: Overall, no statistically significant differences in BIC total (trabecular + cortical) between TiU and SLA were found via LM and B-SEM. BIC values (B-SEM; LM) in both groups revealed a steady rise in trabecular bone attachment to the implant surface after 2, 4 and 8 weeks. In the 2- to 4-week time interval in the TiU group (P = 0.005) as well as in the SLA group (P = 0.01), a statistically significant increase in BIC trabecular could be observed via LM. B-SEM values confirmed the statistically significant increase for TiU (P = 0.001). In both groups, BIC trabecular values after 8 weeks were significantly higher (P <= 0.05) than after 2 weeks (B-SEM; LM). Biomechanical data confirmed the histological data. Conclusion: The two surfaces proved comparable osseointegration in this sheep model.
引用
收藏
页码:898 / 908
页数:11
相关论文
共 31 条
  • [31] Zarb G.e., 1991, INT J PERIODONTICS R, V11, P88