Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model

被引:14
作者
Ernst, Sabrina [1 ]
Stuebinger, Stefan [1 ,2 ]
Schuepbach, Peter [3 ]
Sidler, Michele [1 ]
Klein, Karina [1 ]
Ferguson, Stephen J. [4 ]
von Rechenberg, Brigitte [1 ,2 ]
机构
[1] Univ Zurich, Musculoskeletal Res Unit MRSU, Vetsuisse Fac ZH, Equine Hosp, CH-8057 Zurich, Switzerland
[2] Univ Zurich, Vetsuisse Fac, CABMM, CH-8057 Zurich, Switzerland
[3] Res Lab Microscopy & Histol, Horgen, Switzerland
[4] ETH, Inst Biomech, Zurich, Switzerland
关键词
bone-to-implant contact; dental implants; osseointegration; removal torque test; resonance frequency; SEM backscatter; sheep; surface; ANIMAL-MODELS; TITANIUM; BONE; INTEGRATION;
D O I
10.1111/clr.12411
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to compare two different surfaces of one uniform macro-implant design in order to focus exclusively on the osseointegration properties after 2, 4 and 8 weeks and to discuss the animal model chosen. Material and methods: In six mature sheep, n = 36 implants with a highly crystalline and phosphate-enriched anodized titanium oxide surface (TiU) and n = 36 implants with a hydrophilic, sandblasted, large grit and acid-etched surface (SLA) were placed in the pelvic bone. TiU implants were custom-made to match the SLA implant design. The implant stability and bone-to-implant contact (BIC) were assessed by resonance frequency (ISQ), backscatter scanning electron microscopy (B-SEM), light microscopy (LM), micro-CT and intravital fluorochrome staining. Biomechanical removal torque testing was performed. Results: Overall, no statistically significant differences in BIC total (trabecular + cortical) between TiU and SLA were found via LM and B-SEM. BIC values (B-SEM; LM) in both groups revealed a steady rise in trabecular bone attachment to the implant surface after 2, 4 and 8 weeks. In the 2- to 4-week time interval in the TiU group (P = 0.005) as well as in the SLA group (P = 0.01), a statistically significant increase in BIC trabecular could be observed via LM. B-SEM values confirmed the statistically significant increase for TiU (P = 0.001). In both groups, BIC trabecular values after 8 weeks were significantly higher (P <= 0.05) than after 2 weeks (B-SEM; LM). Biomechanical data confirmed the histological data. Conclusion: The two surfaces proved comparable osseointegration in this sheep model.
引用
收藏
页码:898 / 908
页数:11
相关论文
共 31 条
  • [1] Osseointegration and stability of a modified sand-blasted acid-etched implant: an experimental pilot study in sheep
    Abdel-Haq, Jawad
    Karabuda, Cuneyt Z.
    Arisan, Volkan
    Mutlu, Zihni
    Kurkcu, Mehmet
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (03) : 265 - 274
  • [2] The effect of thread pattern upon implant osseointegration
    Abuhussein, Heba
    Pagni, Giorgio
    Rebaudi, Alberto
    Wang, Hom-Lay
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) : 129 - 136
  • [3] Hard tissue implant interface
    Albrektsson, T.
    [J]. AUSTRALIAN DENTAL JOURNAL, 2008, 53 : S34 - S38
  • [4] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [5] State of the art of oral implants
    Albrektsson, Tomas
    sennerby, Lars
    Wennerberg, Ann
    [J]. PERIODONTOLOGY 2000, 2008, 47 : 15 - 26
  • [6] In vivo behavior of three different injectable hydraulic calcium phosphate cements
    Apelt, D
    Theiss, F
    El-Warrak, AO
    Zlinszky, K
    Bettschart-Wolfisberger, R
    Bohner, M
    Matter, S
    Auer, JA
    von Rechenberg, B
    [J]. BIOMATERIALS, 2004, 25 (7-8) : 1439 - 1451
  • [7] Influence of surface roughness and shape on microdamage of the osseous surface adjacent to titanium dental implants
    Bartold, P. M.
    Kuliwaba, J. S.
    Lee, V.
    Shah, S.
    Marino, V.
    Fazzalari, N. L.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (06) : 613 - 618
  • [8] Ferguson SJ, 2008, INT J ORAL MAX IMPL, V23, P1037
  • [9] EFFECT OF SEX STEROIDS ON PEAK BONE-DENSITY OF GROWING-RABBITS
    GILSANZ, V
    ROE, TF
    GIBBENS, DT
    SCHULZ, EE
    CARLSON, ME
    GONZALEZ, O
    BOECHAT, MI
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (04): : E416 - E421
  • [10] An Experimental Comparison of Two Different Clinically Used Implant Designs and Surfaces
    Gottlow, Jan
    Barkamo, Sargon
    Sennerby, Lars
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e204 - e212