Multiple-Loop Digital Control Method for a 400-Hz Inverter System Based on Phase Feedback

被引:53
作者
Li, Chen [1 ]
Ji, Shi-ming [2 ]
Tan, Da-peng [2 ,3 ]
机构
[1] China Jiliang Univ, Dept Qual & Safety Engn, Hangzhou 310018, Peoples R China
[2] Zhejiang Univ Technol, Minist Educ Zhejiang Prov, Key Lab E&M, Hangzhou 310014, Peoples R China
[3] State Key Lab Fluid Power Transmiss & Control, Hangzhou 310027, Peoples R China
关键词
Medium frequency; multiple-loop control; phase feedback; three-phase combined inverter; unipolar SPWM; PLL; VOLTAGE; 3-PHASE; IMPLEMENTATION; FREQUENCY; ACCURATE; STRATEGY; DESIGN;
D O I
10.1109/TPEL.2012.2188043
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To keep phase balance and improve output voltage quality, a novel multiple-loop control system in 400-Hz inverter power supply based on unipolar sinusoidal pulse width modulation (SPWM) is proposed. The causes of phase imbalance in a three-phase combined inverter power system are analyzed, and a new multiple-loop control strategy based on phase control is presented to eliminate it. For reducing the total harmonic distortion (THD) of high-power inverter output, unipolar SPWM is added with this new control strategy. The designs of drive circuit and snubber circuit are discussed to eliminate dead time effects and voltage oscillation. The stability of the control system is analyzed and the power system and the control strategies are realized with digital signal processing. Contrastive simulation results indicate the advantages and the correctness of this novel controller for inverter. A three-phase combined inverter system based on a multiple-loop control strategy is constructed, and experimental results show that the inverter system can make a phase difference between each phase less than 2 degrees, and the THD of output voltage can be controlled within 2%.
引用
收藏
页码:408 / 417
页数:10
相关论文
共 28 条
[1]  
A A.-A.O., 2011, EUROCON - International Conference on Computer as a Tool (EUROCON), 2011 IEEE, P1
[2]   Analysis and design of a multiple feedback loop control strategy for single-phase voltage-source UPS inverters [J].
AbdelRahim, NM ;
Quaicoe, JE .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1996, 11 (04) :532-541
[3]  
Afarulrazi A. B., 2010, 2010 International Conference on Computer Applications and Industrial Electronics (ICCAIE), P671, DOI 10.1109/ICCAIE.2010.5735019
[4]   Differential Buck DC-DC Chopper Mode Inverters With High-Frequency Link [J].
Chen, Daolian ;
Wang, Guoling .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (05) :1444-1451
[5]   Digital PLL control for single-phase photovoltaic system [J].
Choi, JW ;
Kim, YK ;
Kim, HG .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (01) :40-46
[6]   Precision control of single-phase PWM inverter using PLL compensation [J].
Chung, SK ;
Shin, HB ;
Lee, HW .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (02) :429-436
[7]   A phase tracking system for three phase utility interface inverters [J].
Chung, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :431-438
[8]   Accurate and Less-Disturbing Active Anti-Islanding Method based on PLL for Grid-Connected PV Inverters [J].
Ciobotaru, M. ;
Agelidis, V. ;
Teodorescu, R. .
2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, :4569-+
[9]   Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters [J].
Ciobotaru, Mihai ;
Agelidis, Vassilios G. ;
Teodorescu, Remus ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (06) :1576-1584
[10]   Single-Phase Inverter-Control Techniques for Interfacing Renewable Energy Sources With Microgrid-Part II: Series-Connected Inverter Topology to Mitigate Voltage-Related Problems Along With Active Power Flow Control [J].
Dasgupta, Souvik ;
Sahoo, Sanjib Kumar ;
Panda, Sanjib Kumar ;
Amaratunga, Gehan A. J. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (03) :732-746