In vitro pharmacokinetic phantom for two-compartment modeling in DCE-MRI

被引:0
作者
Wahyulaksana, Geraldi [1 ]
Saporito, Salvatore [1 ]
den Boer, Jacques A. [1 ]
Herold, Ingeborg H. F. [2 ]
Mischi, Massimo [1 ]
机构
[1] Eindhoven Univ Technol, Dept Elect Engn, NL-5612 AZ Eindhoven, Netherlands
[2] Catharina Hosp, Dept Anesthesiol, NL-5623 EJ Eindhoven, Netherlands
关键词
DCE-MRI; in vitro phantom; pharmacokinetic modeling; two-compartmental model; time-intensity curve; CONTRAST-ENHANCED MRI; TREATMENT RESPONSE; BREAST-CANCER; PARAMETERS; BLOOD; FLOW; PERFUSION; TRACER; UNCERTAINTY; CIRCULATION;
D O I
10.1088/1361-6560/aae33b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is an established minimally-invasive method for assessment of extravascular leakage, hemodynamics, and tissue viability. However, differences in acquisition protocols, variety of pharmacokinetic models, and uncertainty on physical sources of MR signal hamper the reliability and widespread use of DCE-MRI in clinical practice. Measurements performed in a controlled in vitro setup could be used as a basis for standardization of the acquisition procedure, as well as objective evaluation and comparison of pharmacokinetic models. In this paper, we present a novel flow phantom that mimics a two-compartmental (blood plasma and extravascular extracellular space/EES) vascular bed, enabling systemic validation of acquisition protocols. The phantom consisted of a hemodialysis filter with two compartments, separated by hollow fiber membranes. The aim of this phantom was to vary the extravasation rate by adjusting the flow in the two compartments. Contrast agent transport kinetics within the phantom was interpreted using two-compartmental pharmacokinetic models. Boluses of gadolinium-based contrast-agent were injected in a tube network connected to the hollow fiber phantom; time-intensity curves (TICs) were obtained from image series, acquired using a T1-weighted DCE-MRI sequence. Under the assumption of a linear dilution system, the TICs obtained from the input and output of the system were then analyzed by a system identification approach to estimate the trans-membrane extravasation rates in different flow conditions. To this end, model-based deconvolution was employed to determine (identify) the impulse response of the investigated dilution system. The flow rates in the EES compartment significantly and consistently influenced the estimated extravasation rates, in line with the expected trends based on simulation results. The proposed phantom can therefore be used to model a two-compartmental vascular bed and can be employed to test and optimize DCE-MRI acquisition sequences in order to determine a standardized acquisition procedure leading to consistent quantification results.
引用
收藏
页数:13
相关论文
共 50 条
[41]   Quantitative DCE-MRI modeling on tumor diagnosis and treatment effect evaluation [J].
Wang, Haoyu ;
Bao, Shanglian .
OPTICAL SENSORS AND BIOPHOTONICS III, 2011, 8311
[42]   Histogram analysis of quantitative pharmacokinetic parameters on DCE-MRI: correlations with prognostic factors and molecular subtypes in breast cancer [J].
Nagasaka, Ken ;
Satake, Hiroko ;
Ishigaki, Satoko ;
Kawai, Hisashi ;
Naganawa, Shinji .
BREAST CANCER, 2019, 26 (01) :113-124
[43]   Effect of Radiation on DCE-MRI Pharmacokinetic Parameters in a Rabbit Model of Compromised Maxillofacial Wound Healing: A Pilot Study [J].
Piotrowski, Stacey L. ;
Wilson, Lindsay ;
Maldonado, Kiersten L. ;
Tailor, Ramesh ;
Hill, Lori R. ;
Bankson, James A. ;
Lai, Stephen ;
Kasper, F. Kurtis ;
Young, Simon .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 78 (06) :1034.e1-1034.e10
[44]   A multi-parametric PET/MRI study of breast cancer: Evaluation of DCE-MRI pharmacokinetic models and correlation with diffusion and functional parameters [J].
Inglese, Marianna ;
Cavaliere, Carlo ;
Monti, Serena ;
Forte, Ernesto ;
Incoronato, Mariarosaria ;
Nicolai, Emanuele ;
Salvatore, Marco ;
Aiello, Marco .
NMR IN BIOMEDICINE, 2019, 32 (01)
[45]   Dual-input two-compartment pharmacokinetic model of dynamic contrast-enhanced magnetic resonance imaging in hepatocellular carcinoma [J].
Yang, Jian-Feng ;
Zhao, Zhen-Hua ;
Zhang, Yu ;
Zhao, Li ;
Yang, Li-Ming ;
Zhang, Min-Ming ;
Wang, Bo-Yin ;
Wang, Ting ;
Lu, Bao-Chun .
WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (13) :3652-3662
[46]   Quantification of DCE-MRI: pharmacokinetic parameter ratio between TOI and RR in reference region model [J].
Lee, Joonsang .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :2837-2840
[47]   Analysis of Prostate DCE-MRI Comparison of Fast Exchange Limit and Fast Exchange Regimen Pharmacokinetic Models in the Discrimination of Malignant From Normal Tissue [J].
Lowry, Martin ;
Zelhof, Bashar ;
Liney, Gary P. ;
Gibbs, Peter ;
Pickles, Martin D. ;
Turnbull, Lindsay W. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (09) :577-584
[48]   Computer-aided diagnosis of breast DCE-MRI using pharmacokinetic model and 3-D morphology analysis [J].
Wang, Teh-Chen ;
Huang, Yan-Hao ;
Huang, Chiun-Sheng ;
Chen, Jeon-Hor ;
Huang, Guei-Yu ;
Chang, Yeun-Chung ;
Chang, Ruey-Feng .
MAGNETIC RESONANCE IMAGING, 2014, 32 (03) :197-205
[49]   Comparative study iinto the robustness of compartmental modeling and model-free analysis in DCE-MRI studies [J].
Roberts, C ;
Issa, B ;
Stone, A ;
Jackson, A ;
Waterton, JC ;
Parker, GJM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (04) :554-563
[50]   Radiomic features of axillary lymph nodes based on pharmacokinetic modeling DCE-MRI allow preoperative diagnosis of their metastatic status in breast cancer [J].
Luo, Hong-Bing ;
Liu, Yuan-Yuan ;
Wang, Chun-Hua ;
Qing, Hao-Miao ;
Wang, Min ;
Zhang, Xin ;
Chen, Xiao-Yu ;
Xu, Guo-Hui ;
Zhou, Peng ;
Ren, Jing .
PLOS ONE, 2021, 16 (03)