In vitro pharmacokinetic phantom for two-compartment modeling in DCE-MRI

被引:0
|
作者
Wahyulaksana, Geraldi [1 ]
Saporito, Salvatore [1 ]
den Boer, Jacques A. [1 ]
Herold, Ingeborg H. F. [2 ]
Mischi, Massimo [1 ]
机构
[1] Eindhoven Univ Technol, Dept Elect Engn, NL-5612 AZ Eindhoven, Netherlands
[2] Catharina Hosp, Dept Anesthesiol, NL-5623 EJ Eindhoven, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 20期
关键词
DCE-MRI; in vitro phantom; pharmacokinetic modeling; two-compartmental model; time-intensity curve; CONTRAST-ENHANCED MRI; TREATMENT RESPONSE; BREAST-CANCER; PARAMETERS; BLOOD; FLOW; PERFUSION; TRACER; UNCERTAINTY; CIRCULATION;
D O I
10.1088/1361-6560/aae33b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is an established minimally-invasive method for assessment of extravascular leakage, hemodynamics, and tissue viability. However, differences in acquisition protocols, variety of pharmacokinetic models, and uncertainty on physical sources of MR signal hamper the reliability and widespread use of DCE-MRI in clinical practice. Measurements performed in a controlled in vitro setup could be used as a basis for standardization of the acquisition procedure, as well as objective evaluation and comparison of pharmacokinetic models. In this paper, we present a novel flow phantom that mimics a two-compartmental (blood plasma and extravascular extracellular space/EES) vascular bed, enabling systemic validation of acquisition protocols. The phantom consisted of a hemodialysis filter with two compartments, separated by hollow fiber membranes. The aim of this phantom was to vary the extravasation rate by adjusting the flow in the two compartments. Contrast agent transport kinetics within the phantom was interpreted using two-compartmental pharmacokinetic models. Boluses of gadolinium-based contrast-agent were injected in a tube network connected to the hollow fiber phantom; time-intensity curves (TICs) were obtained from image series, acquired using a T1-weighted DCE-MRI sequence. Under the assumption of a linear dilution system, the TICs obtained from the input and output of the system were then analyzed by a system identification approach to estimate the trans-membrane extravasation rates in different flow conditions. To this end, model-based deconvolution was employed to determine (identify) the impulse response of the investigated dilution system. The flow rates in the EES compartment significantly and consistently influenced the estimated extravasation rates, in line with the expected trends based on simulation results. The proposed phantom can therefore be used to model a two-compartmental vascular bed and can be employed to test and optimize DCE-MRI acquisition sequences in order to determine a standardized acquisition procedure leading to consistent quantification results.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Fitting the Two-Compartment Model in DCE-MRI by Linear Inversion
    Flouri, Dimitra
    Lesnic, Daniel
    Sourbron, Steven P.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 998 - 1006
  • [2] Renal perfusion in acute kidney injury with DCE-MRI: Deconvolution analysis versus two-compartment filtration model
    Zoellner, Frank G.
    Zimmer, Fabian
    Klotz, Sarah
    Hoeger, Simone
    Schad, Lothar R.
    MAGNETIC RESONANCE IMAGING, 2014, 32 (06) : 781 - 785
  • [3] TWO TISSUE COMPARTMENT MODEL IN DCE-MRI: A BAYESIAN APPROACH
    Kaercher, Julia C.
    Schmid, Volker J.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 724 - 727
  • [4] Renal compartment segmentation in DCE-MRI images
    Yang, Xin
    Minh, Hung Le
    Cheng, Kwang-Ting
    Sung, Kyung Hyun
    Liu, Wenyu
    MEDICAL IMAGE ANALYSIS, 2016, 32 : 269 - 280
  • [5] Functional imaging of acute kidney injury at 3 Tesla: Investigating multiple parameters using DCE-MRI and a two-compartment filtration model
    Zoellner, Frank G.
    Zimmer, Fabian
    Klotz, Sarah
    Hoeger, Simone
    Schad, Lothar R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (01): : 58 - 65
  • [6] Portable perfusion phantom for quantitative DCE-MRI of the abdomen
    Kim, Harrison
    Mousa, Mina
    Schexnailder, Patrick
    Hergenrother, Robert
    Bolding, Mark
    Ntsikoussalabongui, Bernard
    Thomas, Vinoy
    Morgan, Desiree E.
    MEDICAL PHYSICS, 2017, 44 (10) : 5198 - 5209
  • [7] Assessing Treatment Response Through Generalized Pharmacokinetic Modeling of DCE-MRI Data
    Kontopodis, Eleftherios
    Kanli, Georgia
    Manikis, Georgios C.
    Van Cauter, Sofie
    Marias, Kostas
    CANCER INFORMATICS, 2015, 14 : 41 - 51
  • [8] A synthetic phantom for quality assessment of DCE-MRI quantification
    Chao, S. L.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S22 - S22
  • [9] Blind estimation of pharmacokinetic parameters in cardiac DCE-MRI
    Jacob Fluckiger
    Matthias Schabel
    Edward DiBella
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [10] Theoretical Compartment Modeling of DCE-MRI Data Based on the Transport across Physiological Barriers in the Brain
    Fanea, Laura
    David, Leontin I.
    Lebovici, Andrei
    Carbone, Francesca
    Sfrangeu, Silviu A.
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2012, 2012