MOMENT CONTRIBUTION CAPACITY OF TENDON PRESTRESSED PARTIAL ON CONCRETE BEAM-COLUMN JOINT INTERIOR ACCORDING TO PROVISIONS ACI 318-2008 CHAPTER 21.5.2.5(c) DUE TO CYCLIC LATERAL LOADS

被引:5
作者
Astawa, Made Dharma [1 ,2 ]
Raka, IGusti Putu [3 ]
Tavio [3 ]
机构
[1] Univ Pembangunan Nas Vet, Civil Engn Departement, Surabaya, East Java, Indonesia
[2] Fac Civil Engn & Planning ITS Surabaya Indonesia, Civil Engn Struct, Surabaya, East Java, Indonesia
[3] Fac Civil Engn & Planning ITS, Dept Civil Engn, Surabaya, Indonesia
来源
3RD BALI INTERNATIONAL SEMINAR ON SCIENCE & TECHNOLOGY (BISSTECH 2015) | 2016年 / 58卷
关键词
Interior beam-column joint; partial prestressed; tendon moment contribution; ductility;
D O I
10.1051/matecconf/20165804005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This research designed a partial prestressed concrete beam-column with reinforced concrete interior joint, using square columns of 400/400 mm, reinforcement 6 D16 + 4D13, section beam 250/400 mm, tensile reinforcement 5 D13, compression reinforcement 3 D13 + 2 strand tendon D12,7 mm, and joint without plastic hinge, then tested in laboratory with lateral cyclic loads on peak column, static axial load 1120 kN on the centre column, to get the tendon capacity to assume positive and negative bending moments due to lateral load, according to provisions of ACI 318-2008 part 21.5.2.5 (c). Test results showed that the moment tendon contribution on beam section, in the tensile area, the positive and negative moment both on the left side or the right side column are all qualified (< 25 %). In compression area, the positive moments on left and right columns are not qualified at all (> 25 %). As for the negative moment, either left or right side column are all qualified (< 25 %). Ductility, compression, and tensile ductility on drift ratio 3.50% are all qualified (> 4.0). Although the contribution of positive moment capacity tendon in compression areas does not qualify, in overall, the reliability and ductility of the structure qualify.
引用
收藏
页数:8
相关论文
共 29 条
[1]  
Alcocer Sergio M., 2013, GUIDE TESTING REINFO, P8
[2]  
Allam Said M., 2013, ALEX ENG J, P164
[3]  
American Concrete Institute, 2008, 318M08 ACI
[4]  
[Anonymous], 2013, 032847 SNI CONCR LAB
[5]  
[Anonymous], 0317262012 SNI BSN
[6]  
Astawa Made D, 2013, ELSEVIER PROSEDIA EN, V54, P419
[7]  
Barbara Chang, 2014, ACI STRUKTURAL J, P1330
[8]  
Blackeley Roger W. G, 1971, ACI J
[9]  
Chaudhari S., 2014, INT J COMPUT APPL, V102, P35
[10]  
El-Sheikh Magdy T, 1999, PCI J