Does crutch length influence gait parameters after total hip replacement surgery?

被引:3
作者
Freddolini, Marco [1 ]
Esposito, Francesco [1 ,2 ]
Marcucci, Massimiliano [1 ,2 ,3 ]
Corvi, Andrea [1 ,2 ]
Braccio, Palmina [1 ]
Latella, Leonardo [1 ,3 ]
机构
[1] Fdn ONLUS Cammino, Lab Congiunto Anal Movimento, Piazza Spartaco Lavignini 1, I-50054 Fucecchio, FI, Italy
[2] Univ Florence, Ind Engn Dept, Via S Marta 3, I-50139 Florence, FI, Italy
[3] Inst Ctr Eccellenza Sostituz Articolari Toscana C, Piazza Spartaco Lavignini 1, I-50054 Fucecchio, FI, Italy
关键词
Total hip replacement; Crutch setup; Gait; Rehabilitation; Symmetry index; GROUND REACTION FORCES; CANE LENGTH; ASSISTIVE DEVICES; EXERCISE PROGRAM; WALKING AIDS; BALANCE; PEOPLE; TIME; HOME; OSTEOARTHRITIS;
D O I
10.1016/j.gaitpost.2017.07.035
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
After total hip replacement surgery, crutches are often prescribed to enable patients to walk independently. Purpose of this study was to evaluate possible crutch length influence on gait performance and symmetry, including spatiotemporal and kinetics parameters. Thirty patients were randomly assigned to elbow flexed (EF) or elbow extended (EE) crutch setup. Subjects were asked to walk on the laboratory path, instrumented with motion tracking system and force platforms. Spatiotemporal gait parameters and ground reaction force (GRF) parameters for both limbs and crutch support were evaluated. In addition, limb symmetry was evaluated for both gait and force parameters using the symmetry index. Variability was quantified for base of support width, stride time and length as the coefficient of variation. Results showed that cadence and walking speed were not significantly different, but stride length significantly decreased and base of support width increased for the EF group when compared to the EE group. Operated limb GRF parameters were significantly decreased for the EF group, while crutch force parameters decreased for the EE group. Furthermore, the EF group showed greater stride length variability and asymmetry of force and spatiotemporal parameters than EE group did. The results of the present study showed that EF and EE setups did not assist patients equally during walking, with EE setup allowing more load bearing on the operated side, reducing load on the crutch and asymmetries in gait parameters when compared to the EF setup. This may help clinicians in rationalizing crutch setup for patients after total hip replacement surgery.
引用
收藏
页码:262 / 267
页数:6
相关论文
共 40 条
  • [1] Exploring seniors' views on the use of assistive devices in fall prevention
    Aminzadeh, F
    Edwards, N
    [J]. PUBLIC HEALTH NURSING, 1998, 15 (04) : 297 - 304
  • [2] EXPERIMENTAL OSTEOARTHRITIS INDUCED BY SELECTIVE MYECTOMY AND TENDOTOMY
    ARSEVER, CL
    BOLE, GG
    [J]. ARTHRITIS AND RHEUMATISM, 1986, 29 (02): : 251 - 261
  • [3] Assistive devices for balance and mobility: Benefits, demands, and adverse consequences
    Bateni, H
    Maki, BE
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (01): : 134 - 145
  • [4] Can use of walkers or canes impede lateral compensatory stepping movements?
    Bateni, H
    Heung, E
    Zettel, J
    Mcllroy, WE
    Maki, BE
    [J]. GAIT & POSTURE, 2004, 20 (01) : 74 - 83
  • [5] Stance time and step width variability have, unique contributing impairments in older persons
    Brach, Jennifer S.
    Studenski, Stephanie
    Perera, Subashan
    VanSwearingen, Jessie M.
    Newman, Anne B.
    [J]. GAIT & POSTURE, 2008, 27 (03) : 431 - 439
  • [6] Do traditionally recommended cane lengths equally influence walking in patients after stroke?
    Cha, Yong-Jun
    [J]. DISABILITY AND HEALTH JOURNAL, 2015, 8 (01) : 136 - 139
  • [7] Changes in knee moments with contralateral versus ipsilateral cane usage in females with knee osteoarthritis
    Chan, GNY
    Smith, AW
    Kirtley, C
    Tsang, WWN
    [J]. CLINICAL BIOMECHANICS, 2005, 20 (04) : 396 - 404
  • [8] RELATIONSHIPS AMONG CANE FITTING, FUNCTION, AND FALLS
    DEAN, E
    ROSS, J
    [J]. PHYSICAL THERAPY, 1993, 73 (08): : 494 - 504
  • [9] DEAN E, 1993, PHYS THER, V73, P502, DOI 10.1093/ptj/73.8.502
  • [10] Effects of Contralateral Versus Ipsilateral Cane Use on Gait in People with Knee Osteoarthritis
    Fang, Meika A.
    Heiney, Constance
    Yentes, Jennifer M.
    Harada, Nancy D.
    Masih, Sulabha
    Perell-Gerson, Karen L.
    [J]. PM&R, 2015, 7 (04) : 400 - 406