ECG data compression using fast Walsh transform and its clinical acceptability

被引:3
作者
Kulkarni, PK [1 ]
Kumar, V [1 ]
Verma, HK [1 ]
机构
[1] UNIV ROORKEE, DEPT ELECT ENGN, ROORKEE 247667, UTTAR PRADESH, INDIA
关键词
D O I
10.1080/00207729708929443
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Data compression techniques can be grouped into three categories, direct and transformation compression and parameter extraction. The principles and details of ECG data compression implementation using fast Walsh transform are presented. Performance evaluation has been made on the basis of compression ratio and visual comparison. To know the extent to which the clinical information preserved in rite reconstructed signal, peak and boundary measurements were made on both the reconstructed and original signal, and then compared. As the number of fast Walsh transform coefficients are reduced, the compression ratio increases. At higher compression ratios deviations in the R-peak are found to be higher than those in the other ECG peaks. Peak and boundary measurements reveal clinical acceptability of the compression algorithm, because the errors are quite tolerable. It is also worth noting that artefacts such as electromyographic noise are better eliminated because of filtering, and this also makes the signal compatible to cardiologists for visual examination. The experimental results show that a compression ratio of four is acceptable to preserve the clinical information.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 24 条
[1]   A NEW DATA-REDUCTION ALGORITHM FOR REAL-TIME ECG ANALYSIS [J].
ABENSTEIN, JP ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (01) :43-48
[2]   ELECTROCARDIOGRAPHIC DATA COMPRESSION VIA ORTHOGONAL TRANSFORMS [J].
AHMED, N ;
MILNE, PJ ;
HARRIS, SG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1975, 22 (06) :484-487
[3]  
[Anonymous], 1985, Eur Heart J, V6, P815
[4]  
BEAUCHAMP KG, 1975, WALSH FUNCTIONS THEI, P40
[5]   ECG DATA-COMPRESSION USING DOUBLE LOGARITHMIC QUANTIZATION OF WALSH SPECTRUM [J].
BERTI, E ;
CHIARALUCE, F ;
EVANS, NE ;
MCKEE, JJ .
ELECTRONICS LETTERS, 1995, 31 (13) :1025-1026
[6]   Wavelet packet-based compression of single lead ECG [J].
Bradie, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (05) :493-501
[7]  
CHEN J, 1993, IEICE T INF SYST, VE76D, P1454
[8]  
Cohen A., 1990, P IEEE 90 S A S COMM, P45
[9]   AZTEC A PREPROCESSING PROGRAM FOR REAL-TIME ECG RHYTHM ANALYSIS [J].
COX, JR ;
NOLLE, FM ;
FOZZARD, HA ;
OLIVER, GC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1968, BM15 (02) :128-&
[10]  
De Perez T. A., 1987, Journal of Clinical Engineering, V12, P373