Utility of Dual-Energy CT Virtual keV Monochromatic Series for the Assessment of Spinal Transpedicular Hardware-Bone Interface

被引:49
作者
Srinivasan, Ashok [1 ]
Hoeffner, Ellen [1 ]
Ibrahim, Mohannad [1 ]
Shah, Gaurang V. [1 ]
LaMarca, Frank [2 ]
Mukherji, Suresh K. [1 ]
机构
[1] Univ Michigan Hlth Syst, Div Neuroradiol, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan Hlth Syst, Dept Neurosurg, Ann Arbor, MI 48109 USA
关键词
dual-energy CT; gemstone spectral imaging; metal artifact; spine hardware; DIAGNOSTIC REFERENCE LEVELS; METAL ARTIFACT REDUCTION;
D O I
10.2214/AJR.12.9736
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our aim was to evaluate the utility of dual-energy CT (DECT) virtual kilo-electron volt (keV) monochromatic images for the visualization of the transpedicular screw-bone interface after spinal fusion. MATERIALS AND METHODS. This retrospective study included postfusion spine CT studies performed from October 2011 through April 2012 on a dual-energy 64-MDCT unit (Discovery CT750 HD). Studies were postprocessed on an Advantage Windows workstation (version 4.4) by two neuroradiologists with creation of monochromatic images from 40 to 140 keV. Each reader graded the screw-bone interfaces on the 70-keV images (used for clinical interpretation) and on the monochromatic series using a 5-point scale (1 [uninterpretable] to 5 [excellent]). The grades of the interfaces were compared using the Wilcoxon signed rank test to detect differences between the 70-keV image and the monochromatic series. RESULTS. Ninety-two transpedicular screws in 10 patients were studied. Significant improvement in the visibility of the hardware-bone interface was seen on the monochromatic series compared with the 70-keV images: The median grade for the monochromatic series was 4 (range, 2-5) for both readers, whereas the median grade for the 70-keV images was 3 (range, 2-4) for reader 1 and 2 (range, 2-3) for reader 2 (both, p < 0.001). The interobserver agreement using weighted kappa was 0.51 for grading screw-bone interface visualization. The volume CT dose index was 29.5 mGy in all patients and the mean dose-length product was 805.2 mGy x cm. CONCLUSION. Monochromatic images generated on gemstone spectral DECT are beneficial in the reduction of metallic streak artifact and enable better visualization of the hardware-bone interface than the 70-keV series in patients treated with spinal transpedicular screw fixation.
引用
收藏
页码:878 / 883
页数:6
相关论文
共 16 条
[1]   Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429
[2]   Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients [J].
Dakhil-Jerew, Fras ;
Jadeja, H. ;
Cohen, A. ;
Shepperd, J. A. N. .
EUROPEAN SPINE JOURNAL, 2009, 18 (10) :1486-1493
[3]  
Esses SI, 1993, SPINE, V18, P2238
[4]   Establishment of CT diagnostic reference levels in Ireland [J].
Foley, S. J. ;
McEntee, M. F. ;
Rainford, L. A. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018) :1390-1397
[5]   The use of pedicle-screw internal fixation for the operative treatment of spinal disorders [J].
Gaines, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1458-1476
[6]   Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels [J].
Guggenberger, R. ;
Winklhofer, S. ;
Osterhoff, G. ;
Wanner, G. A. ;
Fortunati, M. ;
Andreisek, G. ;
Alkadhi, H. ;
Stolzmann, P. .
EUROPEAN RADIOLOGY, 2012, 22 (11) :2357-2364
[7]   Spectral Hounsfield units: a new radiological concept [J].
Hurrell, Michael Anthony ;
Butler, Anthony Philip Howard ;
Cook, Nicholas James ;
Butler, Philip Howard ;
Ronaldson, J. Paul ;
Zainon, Rafidah .
EUROPEAN RADIOLOGY, 2012, 22 (05) :1008-1013
[8]   Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations [J].
Jutte, PC ;
Castelein, RM .
EUROPEAN SPINE JOURNAL, 2002, 11 (06) :594-598
[9]   Dual-energy CT revisited with multidetector CT: review of principles and clinical applications [J].
Karcaaltincaba, Musturay ;
Aktas, Aykut .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (03) :181-194
[10]   Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software [J].
Lee, Young Han ;
Park, Kwan Kyu ;
Song, Ho-Taek ;
Kim, Sungjun ;
Suh, Jin-Suck .
EUROPEAN RADIOLOGY, 2012, 22 (06) :1331-1340