Geant4 code for simulation attenuation of gamma rays through scintillation detectors

被引:46
作者
Medhat, M. E. [1 ,2 ]
Wang, Yifang [2 ]
机构
[1] Nucl Res Ctr, Expt Nucl Phys Dept, Cairo, Egypt
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
关键词
Scintillation detectors; Mass attenuation coefficient; Geant4; EFFECTIVE ATOMIC NUMBERS; COEFFICIENTS; SOIL;
D O I
10.1016/j.anucene.2013.06.034
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Geant4-based Monte Carlo simulations have been carried out for studying mass attenuation for different types of scintillation detectors at different photon energies. The simulations showed that the calculated mass attenuation values are close to experimental values better than the other obtained theoretical data base for the same detector. The results indicate that Geant4 can be applied to estimate mass attenuation for various materials and energies. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:316 / 320
页数:5
相关论文
共 14 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
[Anonymous], GEANT4 COLL PHYS REF
[3]  
Berger M., NIST, PML, DOI [10.18434/T48G6X, DOI 10.18434/T48G6X]
[4]   Investigation on radiation shielding parameters of bismuth borosilicate glass from 1 keV to 100 GeV [J].
Chanthima, N. ;
Kaewkhao, J. .
ANNALS OF NUCLEAR ENERGY, 2013, 55 :23-28
[5]   Soil bulk density evaluated by gamma-ray attenuation: Analysis of system geometry [J].
Costa, J. C. ;
Borges, J. A. R. ;
Pires, L. F. .
SOIL & TILLAGE RESEARCH, 2013, 129 :23-31
[6]  
Demir N., 2013, J RADIOANAL NUCL CHE, DOI DOI 10.1007/510967-013-2494-Y
[7]   An investigation on determination of attenuation coefficients for gamma-rays by Monte Carlo method [J].
Gurler, O. ;
Tarim, U. Akar .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 293 (01) :397-401
[8]  
Knoll G.F., 1989, Radiation Detection and Measurement, V2nd
[9]   Mass attenuation coefficients, effective atomic numbers and effective electron densities for some polymers [J].
Kucuk, Nil ;
Cakir, Merve ;
Isitman, Nihat Ali .
RADIATION PROTECTION DOSIMETRY, 2013, 153 (01) :127-134
[10]   Estimation of effective atomic numbers of some solutions for photon energy absorption in the energy region 0.2-1.5 MeV: An alternative method [J].
Kurudirek, Murat .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 659 (01) :302-306