Reference value of perimeter-derived diameter assessed by three-dimensional transesophageal echocardiography in left atrial appendage occluder size selection

被引:4
作者
Kong, Dehong [1 ,2 ,3 ]
Jiang, Yingying [1 ,2 ,3 ]
Zhang, Xiaochun [2 ]
Jin, Qinchun [2 ]
Dong, Lili [1 ,2 ,3 ]
Zhou, Daxin [2 ]
Shu, Xianhong [1 ,2 ,3 ]
Pan, Cuizhen [1 ,2 ,3 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Echocardiog, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Shanghai Inst Cardiovasc Dis, Shanghai, Peoples R China
[3] Shanghai Inst Med Imaging, Shanghai, Peoples R China
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2020年 / 37卷 / 11期
基金
中国国家自然科学基金;
关键词
left atrial appendage closure; three-dimensional transesophageal echocardiography; transcatheter device; COMPUTED-TOMOGRAPHY; CT ANGIOGRAPHY; CLOSURE; FIBRILLATION; STROKE; PREVENTION; WARFARIN; OUTCOMES; ANATOMY; IMPACT;
D O I
10.1111/echo.14705
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of this study was to investigate the utility of perimeter-derived diameter (PDD) measured by three-dimensional (3D) transesophageal echocardiography (TEE) in predicting the size of left atrial appendage (LAA) occluder. Methods and results Left atrial appendage landing zone diameter (LZD) was measured by two-dimensional (2D) TEE, 3DTEE, and digital subtraction angiography (DSA) as LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD, LZD-DSAmax, respectively, before and during transcatheter LAA closure with Watchman devices in 100 patients. A difference of one or more device size intervals between the predicted size and the size actually implanted was defined as mismatching. Seventy-eight patients were followed up by TEE to obtain occluder compression ratio. The correlation between LZD and the final implanted occluder size was 0.559, 0.641, 0.754, 0.760, 0.782, and 0.848 for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively (P < .001). Matching ratio between the size predicted by retrospective measurements of LZD and the device size actually implanted was 65%, 57%, 66%, 63%, 70%, and 83% for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively. There was no significant difference in LZD value, matching ratio, and compression ratio between the patients with eccentric and noneccentric LAA landing zone (P > .05). Compression ratio of the mismatching subjects was higher than that in the matching subjects when evaluated by LZD-2Dmean, LZD-3Dmean, and LZD-PDD (P < .05). Conclusions Landing zone diameter derived from LAA perimeter measured by preprocedure 3DTEE showed reference value for LAA occluder size selection, providing superior correlation and matching ratio with the final implanted size and indicating the adjustment of oversizing.
引用
收藏
页码:1828 / 1837
页数:10
相关论文
共 25 条
  • [21] Anatomy of the normal left atrial appendage - A quantitative study of age-related changes in 500 autopsy hearts: Implications for echocardiographic examination
    Veinot, JP
    Harrity, PJ
    Gentile, F
    Khandheria, BK
    Bailey, KR
    Eickholt, JT
    Seward, JB
    Tajik, AJ
    Edwards, WD
    [J]. CIRCULATION, 1997, 96 (09) : 3112 - 3115
  • [22] Left Atrial Appendage Studied by Computed Tomography to Help Planning for Appendage Closure Device Placement
    Wang, Yan
    Di Biase, Luigi
    Horton, Rodney P.
    Nguyen, Tuan
    Morhanty, Prasant
    Natale, Andrea
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (09) : 973 - 982
  • [23] Percutaneous Interventions for Left Atrial Appendage Exclusion Options, Assessment, and Imaging Using 2D and 3D Echocardiography
    Wunderlich, Nina C.
    Beigel, Roy
    Swaans, Martin J.
    Ho, Siew Yen
    Siegel, Robert J.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2015, 8 (04) : 473 - 488
  • [24] Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device
    Xu, Bo
    Betancor, Jorge
    Sato, Kimi
    Harb, Serge
    Rehman, Karim Abdur
    Patel, Kunal
    Kumar, Arnav
    Cremer, Paul C.
    Jaber, Wael
    Rodriguez, L. Leonardo
    Schoenhagen, Paul
    Wazni, Oussama
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2018, 12 (01) : 50 - 55
  • [25] Percutaneous closure of the left atrial appendage: The value of real time 3D transesophageal echocardiography and the intraoperative change in the size of the left atrial appendage
    Zhang, Lizi
    Cong, Tao
    Liu, Ansheng
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (03): : 537 - 545