Reference value of perimeter-derived diameter assessed by three-dimensional transesophageal echocardiography in left atrial appendage occluder size selection

被引:4
作者
Kong, Dehong [1 ,2 ,3 ]
Jiang, Yingying [1 ,2 ,3 ]
Zhang, Xiaochun [2 ]
Jin, Qinchun [2 ]
Dong, Lili [1 ,2 ,3 ]
Zhou, Daxin [2 ]
Shu, Xianhong [1 ,2 ,3 ]
Pan, Cuizhen [1 ,2 ,3 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Echocardiog, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Shanghai Inst Cardiovasc Dis, Shanghai, Peoples R China
[3] Shanghai Inst Med Imaging, Shanghai, Peoples R China
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2020年 / 37卷 / 11期
基金
中国国家自然科学基金;
关键词
left atrial appendage closure; three-dimensional transesophageal echocardiography; transcatheter device; COMPUTED-TOMOGRAPHY; CT ANGIOGRAPHY; CLOSURE; FIBRILLATION; STROKE; PREVENTION; WARFARIN; OUTCOMES; ANATOMY; IMPACT;
D O I
10.1111/echo.14705
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of this study was to investigate the utility of perimeter-derived diameter (PDD) measured by three-dimensional (3D) transesophageal echocardiography (TEE) in predicting the size of left atrial appendage (LAA) occluder. Methods and results Left atrial appendage landing zone diameter (LZD) was measured by two-dimensional (2D) TEE, 3DTEE, and digital subtraction angiography (DSA) as LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD, LZD-DSAmax, respectively, before and during transcatheter LAA closure with Watchman devices in 100 patients. A difference of one or more device size intervals between the predicted size and the size actually implanted was defined as mismatching. Seventy-eight patients were followed up by TEE to obtain occluder compression ratio. The correlation between LZD and the final implanted occluder size was 0.559, 0.641, 0.754, 0.760, 0.782, and 0.848 for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively (P < .001). Matching ratio between the size predicted by retrospective measurements of LZD and the device size actually implanted was 65%, 57%, 66%, 63%, 70%, and 83% for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively. There was no significant difference in LZD value, matching ratio, and compression ratio between the patients with eccentric and noneccentric LAA landing zone (P > .05). Compression ratio of the mismatching subjects was higher than that in the matching subjects when evaluated by LZD-2Dmean, LZD-3Dmean, and LZD-PDD (P < .05). Conclusions Landing zone diameter derived from LAA perimeter measured by preprocedure 3DTEE showed reference value for LAA occluder size selection, providing superior correlation and matching ratio with the final implanted size and indicating the adjustment of oversizing.
引用
收藏
页码:1828 / 1837
页数:10
相关论文
共 25 条
  • [1] A comparison of two-dimensional and real-time 3D transoesophageal echocardiography and angiography for assessing the left atrial appendage anatomy for sizing a left atrial appendage occlusion system: impact of volume loading
    Al-Kassou, Baravan
    Tzikas, Apostolos
    Stock, Friederike
    Neikes, Fabian
    Voelz, Alexander
    Omran, Heyder
    [J]. EUROINTERVENTION, 2017, 12 (17) : 2083 - 2091
  • [2] Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation
    Blackshear, JL
    Odell, JA
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (02) : 755 - 759
  • [3] Conformational Pulsatile Changes of the Aortic Annulus Impact on Prosthesis Sizing by Computed Tomography for Transcatheter Aortic Valve Replacement
    Blanke, Philipp
    Russe, Maximillian
    Leipsic, Jonathon
    Reinoehl, Jochen
    Ebersberger, Ullrich
    Suranyi, Pal
    Siepe, Matthias
    Pache, Gregor
    Langer, Mathias
    Schoepf, U. Joseph
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (09) : 984 - 994
  • [4] 3D-printed heart model to guide LAA closure: useful in clinical practice?
    Hachulla, Anne-Lise
    Noble, Stephane
    Guglielmi, Gabriel
    Agulleiro, Daniel
    Mueller, Hajo
    Vallee, Jean-Paul
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (01) : 251 - 258
  • [5] Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial
    Holmes, David R.
    Reddy, Vivek Y.
    Turi, Zoltan G.
    Doshi, Shephal K.
    Sievert, Horst
    Buchbinder, Maurice
    Mullin, Christopher M.
    Sick, Peter
    [J]. LANCET, 2009, 374 (9689) : 534 - 542
  • [6] Long-Term Safety and Efficacy in Continued Access Left Atrial Appendage Closure Registries
    Holmes, David R., Jr.
    Reddy, Vivek Y.
    Gordon, Nicole T.
    Delurgio, David
    Doshi, Shephal K.
    Desai, Amish J.
    Stone, James E., Jr.
    Kar, Saibal
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (23) : 2878 - 2889
  • [7] Left Atrial Appendage Closure as an Alternative to Warfarin for Stroke Prevention in Atrial Fibrillation A Patient-Level Meta-Analysis
    Holmes, David R., Jr.
    Doshi, Shephal K.
    Kar, Saibal
    Price, Matthew J.
    Sanchez, Jose M.
    Sievert, Horst
    Valderrabano, Miguel
    Reddy, Vivek Y.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (24) : 2614 - 2623
  • [8] The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder
    Jia, Dan
    Zhou, Qing
    Song, Hong-ning
    Zhang, Lan
    Chen, Jin-ling
    Liu, Yu
    Kong, Bin
    He, Fa-zhi
    Wang, Yi-jia
    Yang, Yuan-ting
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (10) : 1841 - 1851
  • [9] Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation
    Jilaihawi, Hasan
    Kashif, Mohammad
    Fontana, Gregory
    Furugen, Azusa
    Shiota, Takahiro
    Friede, Gerald
    Makhija, Rakhee
    Doctor, Niraj
    Leon, Martin B.
    Makkar, Raj R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) : 1275 - 1286
  • [10] 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
    Kirchhof, Paulus
    Benussi, Stefano
    Kotecha, Dipak
    Ahlsson, Anders
    Atar, Dan
    Casadei, Barbara
    Castella, Manuel
    Diener, Hans-Christoph
    Heidbuchel, Hein
    Hendriks, Jeroen
    Hindricks, Gerhard
    Manolis, Antonis S.
    Oldgren, Jonas
    Popescu, Bogdan Alexandru
    Schotten, Ulrich
    Van Putte, Bart
    Vardas, Panagiotis
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 (38) : 2893 - +