Characterization of proton beam emission from an electron cyclotron resonance ion source

被引:7
作者
Jain, S. K. [1 ]
Tayyab, M. [1 ]
Bagchi, S. [1 ]
Chakera, J. A. [1 ]
Naik, P. A. [1 ]
机构
[1] Raja Ramanna Ctr Adv Technol, Indore 452013, Madhya Pradesh, India
关键词
Electron cyclotron resonance plasma; Microwave system; Faraday cup; Thomson parabola ion spectrograph; ACCELERATORS; DEPOSITION; POWER;
D O I
10.1016/j.nima.2013.01.002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report here characterization of the ions produced in the Electron Cyclotron Resonance Ion Source (ECRIS) at RRCAT, which operates at 2.45 GHz and is aimed to produce a 50 keV, 30 mA proton beam. The plasma in the source was created using microwave power in the range of 150-1200W. An efficient, single hole, three-electrode ion extraction system was employed to extract the ion beam from the ECRIS, and the extracted ion beam was characterized using a Thomson Parabola Ion Spectrograph, which provides complete information of all the differently charged species present in the plasma. The extracted ion beam current measured up to 8 mA beam current for 25 keV accelerating field and followed the Child-Langmuir law. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 35 条
[1]   ION SOURCES FOR ACCELERATORS IN MATERIALS RESEARCH [J].
ALTON, GD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 73 (02) :221-288
[2]  
[Anonymous], 1987, LAUR87126
[3]   IGUN - A PROGRAM FOR THE SIMULATION OF POSITIVE-ION EXTRACTION INCLUDING MAGNETIC-FIELDS [J].
BECKER, R ;
HERRMANNSFELDT, WB .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04) :2756-2758
[4]  
Becker R., IGUN 6 004 SOFTWARE
[5]  
Bhawalkar D.D., 2003, P IND PART ACC C
[6]   NUCLEAR-ENERGY GENERATION AND WASTE TRANSMUTATION USING AN ACCELERATOR-DRIVEN INTENSE THERMAL-NEUTRON SOURCE [J].
BOWMAN, CD ;
ARTHUR, ED ;
LISOWSKI, PW ;
LAWRENCE, GP ;
JENSEN, RJ ;
ANDERSON, JL ;
BLIND, B ;
CAPPIELLO, M ;
DAVIDSON, JW ;
ENGLAND, TR ;
ENGEL, LN ;
HAIGHT, RC ;
HUGHES, HG ;
IRELAND, JR ;
KRAKOWSKI, RA ;
LABAUVE, RJ ;
LETELLIER, BC ;
PERRY, RT ;
RUSSELL, GJ ;
STAUDHAMMER, KP ;
VERSAMIS, G ;
WILSON, WB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) :336-367
[7]  
Brown I.G., 1989, PHYS TECHNOLOGY ION
[8]  
Celona L., 2000, REV SCI INSTRUM, V71, P2
[9]  
Chapman B., 1980, GLOW DISCHARGE PROCE, DOI DOI 10.1063/1.2914660
[10]   A version of the Trasco Intense Proton Source optimized for accelerator driven system purposes [J].
Ciavola, G ;
Celona, L ;
Gammino, S ;
Presti, M ;
Andò, L ;
Passarello, S ;
Zhang, XZ ;
Consoli, F ;
Chines, F ;
Percolla, C ;
Calzona, V .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05) :1453-1456