Early Outcomes With a Slim, Modiolar Cochlear Implant Electrode Array
被引:58
作者:
McJunkin, Jonathan L.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USAWashington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USA
McJunkin, Jonathan L.
[1
]
Durakovic, Nedim
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USAWashington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USA
Durakovic, Nedim
[1
]
Herzog, Jacques
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USA
Ctr Hearing & Balance Disorders, Chesterfield, MO USAWashington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USA
Herzog, Jacques
[1
,2
]
Buchman, Craig A.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USA
Ctr Hearing & Balance Disorders, Chesterfield, MO USAWashington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USA
Buchman, Craig A.
[1
,2
]
机构:
[1] Washington Univ, Dept Otolaryngol, 660 South Euclid Ave, St Louis, MO 63110 USA
[2] Ctr Hearing & Balance Disorders, Chesterfield, MO USA
Objective: To describe outcomes from cochlear implantation with a new, slim modiolar electrode array. Study Design: Retrospective cohort study. Setting: Tertiary referral centers. Patients: Adult cochlear implant candidates. Interventions: Cochlear implantation with CI532 (Cochlear Corp). Main Outcome Measures: Pre-and postoperative speech perception scores, operative details, and postoperative computed tomography (CT) reconstructions of array location. Results: One hundred seventeen patients are implanted to date. There were eight tip rollovers identified with intraoperative x-ray and resolved with reinsertion. An additional rollover was identified on postoperative CT. CT reconstructions in 17 of 23 patients showed complete scala tympani placement with a wrap factor of 58% (range 53-64%) and a mean insertion angle of 406 degrees (range 360-452 degrees). Three implants demonstrated array translocation with electrodes in the scala vestibuli. Consonant-nucleusconsonant word scores improved from 10% preoperatively to 48% at 3 months postoperatively. Pure-tone thresholds were preserved postoperatively in 37 to 52% of patients across frequencies from 250 to 4000Hz. Functional pure-tone thresholds (<= 80 dB) were recorded in 9 to 25% of patients. Conclusion: CI532 array insertion results in consistent scala tympani location and provides expected audiologic performance. Initial hearing preservation results are not consistent with current electro-acoustic arrays.