Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: Effect on survival, freedom from heart failure, and left ventricular mass regression

被引:152
作者
Ruel, M
Al-Faleh, H
Kulik, A
Chan, KL
Mesana, TG
Burwash, IG
机构
[1] Univ Ottawa, Inst Heart, Div Cardiac Surg, Ottawa, ON, Canada
[2] Univ Ottawa, Inst Heart, Dept Epidemiol, Ottawa, ON, Canada
[3] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON, Canada
关键词
D O I
10.1016/j.jtcvs.2005.10.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The effect of prosthesis-patient mismatch on clinical outcome and left ventricular mass regression after aortic valve replacement remains controversial. Data on whether the clinical effect of prosthesis-patient mismatch depends on left ventricular function at the time of aortic valve replacement are lacking. This study examined the long-term clinical and echocardiographic effects of prosthesis-patient mismatch in patients with and without left ventricular systolic dysfunction at the time of aortic valve replacement. Methods: Preoperative and serial postoperative echocardiograms were performed in 805 adults who underwent aortic valve replacement between 1990 and 2003 and who were subsequently followed up in a dedicated valve clinic (follow-up, mean +/- SD, 5.5 +/- 3.5 years; maximum, 14.2 years). Preoperative left ventricular function was defined as normal (ejection fraction >= 50%) in 548 patients and impaired (ejection fraction >50%) in 257 patients. Results: Patients with impaired preoperative left ventricular function and prosthesis-patient mismatch (indexed effective orifice area <= 0.85 cm(2)/m(2)) had a decreased overall late survival (hazard ratio, 2.8; P=.03), decreased freedom from heart failure symptoms or heart failure death (odds ratio of 5.1 at 3 years after aortic valve replacement; P=.009), and diminished left ventricular mass regression compared with patients with impaired preoperative left ventricular function and no prosthesis patient mismatch. These effects of prosthesis-patient mismatch were not observed in patients with normal preoperative left ventricular function. Conclusions: Prosthesis-patient mismatch at an indexed effective orifice area of 0.85 cm(2)/m(2) or less after aortic valve replacement primarily affects patients with impaired preoperative left ventricular function and results in decreased survival, lower freedom from heart failure, and incomplete left ventricular mass regression. Patients with impaired left ventricular function represent a critical population in whom prosthesis-patient mismatch should be avoided at the time of aortic valve replacement.
引用
收藏
页码:1036 / 1044
页数:9
相关论文
共 30 条
[1]   Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis [J].
Amarelli, C ;
Della Corte, A ;
Romano, G ;
Iasevoli, G ;
Dialetto, G ;
De Santo, LS ;
De Feo, M ;
Torella, M ;
Scardone, M ;
Cotrufo, M .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (03) :512-517
[2]   EFFECT OF PROSTHETIC AORTIC-VALVE DESIGN ON THE DOPPLER-CATHETER GRADIENT CORRELATION - AN INVITRO STUDY OF NORMAL ST-JUDE, MEDTRONIC-HALL, STARR-EDWARDS AND HANCOCK VALVES [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :324-332
[3]   Influence of aortic valve replacement, prosthesis type, and size on functional outcome and ventricular mass in patients with aortic stenosis [J].
Bech-Hanssen, O ;
Caidahl, K ;
Wall, B ;
Mykén, P ;
Larsson, S ;
Wallentin, I .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (01) :57-65
[4]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[5]   DEPENDENCE OF GORLIN FORMULA AND CONTINUITY EQUATION VALVE AREAS ON TRANSVALVULAR VOLUME FLOW-RATE IN VALVULAR AORTIC-STENOSIS [J].
BURWASH, IG ;
THOMAS, DD ;
SADAHIRO, M ;
PEARLMAN, AS ;
VERRIER, ED ;
THOMAS, R ;
KRAFT, CD ;
OTTO, CM .
CIRCULATION, 1994, 89 (02) :827-835
[6]   Small "functional" size after mechanical aortic valve replacement: No risk in young to middle-age patients [J].
de Peppo, AP ;
Zeitani, J ;
Nardi, P ;
Iaci, G ;
Polisca, P ;
De Paulis, R ;
Chiariello, L .
ANNALS OF THORACIC SURGERY, 2005, 79 (06) :1915-1920
[7]   ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR HYPERTROPHY - COMPARISON TO NECROPSY FINDINGS [J].
DEVEREUX, RB ;
ALONSO, DR ;
LUTAS, EM ;
GOTTLIEB, GJ ;
CAMPO, E ;
SACHS, I ;
REICHEK, N .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (06) :450-458
[8]   Guidelines for reporting morbidity and mortality after cardiac valvular operations [J].
Edmunds, LH ;
Clark, RE ;
Cohn, LH ;
Grunkemeier, GL ;
Miller, DC ;
Weisel, RD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (03) :708-711
[9]  
Frapier JM, 2002, J HEART VALVE DIS, V11, P543
[10]   Patient-prosthesis mismatch in aortic valve replacement:: really tolerable? [J].
Fuster, RG ;
Argudo, JAM ;
Albarova, OG ;
Sos, FH ;
López, SC ;
Codoñer, MB ;
Miñano, JAB ;
Albarran, IR .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (03) :441-449