Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography

被引:39
|
作者
Fuchs, Andreas [1 ]
Kuhl, J. Tobias [1 ]
Chen, Marcus Y. [2 ]
Helquist, Steffen [1 ]
Razeto, Marco [3 ]
Arakita, Kazumasa [4 ]
Steveson, Chloe [4 ]
Arai, Andrew E. [2 ]
Kofoed, Klaus F. [1 ,5 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Cardiol, DK-2100 Copenhagen, Denmark
[2] NHLBI, NIH, Bethesda, MD 20892 USA
[3] Toshiba Med Visualizat Syst Europe, Edinburgh, Midlothian, Scotland
[4] Toshiba Med Syst Corp, Otawara, Japan
[5] Univ Copenhagen, Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
关键词
Coronary; Subtraction; CT; CCTA; Angiography; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.jcct.2015.03.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The reader confidence and diagnostic accuracy of coronary CT angiography (CCTA) can be compromised by the presence of calcified plaques and stents causing blooming artifacts. Compared to conventional invasive coronary angiography (ICA), this may cause an overestimation of stenosis severity leading to false-positive results. In a pilot study, we tested the feasibility of a new coronary calcium image subtraction algorithm in relation to reader confidence and diagnostic accuracy. Methods: Forty-three patients underwent clinically indicated ICA and CCTA using a 320-detector row CT. Median Agatston score was 510. Two data sets were reconstructed: a conventional CCTA (CCTA(conv)) and a subtracted CCTA (CCTA(sub)), where calcifications detected on noncontrast images were subtracted from the CCTA. Reader confidence and concordance with ICA for identification of >50% stenosis were recorded. We defined target segments on CCTA(conv), as motion-free coronary segments with calcification or stent and low reader confidence. The effect of CCTA(sub) was assessed. No approval from the ethics committee was required according to Danish law. Results: A total of 76 target segments were identified. The use of coronary calcium image subtraction improved the reader confidence in 66% of these segments. In target segments, specificity (86% vs 65%; P < .01) and positive predictive value (71% vs 51%, P = .03) were improved using CCTA(sub) compared to CCTA(conv), without loss in negative predictive value. Conclusions: Our initial experience with coronary calcium image subtraction suggests that it is feasible and could lead to an improvement in reader confidence and diagnostic accuracy for identification of significant coronary artery disease. (C) 2015 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:393 / 398
页数:6
相关论文
共 50 条
  • [1] Subtraction coronary CT angiography using second-generation 320-detector row CT
    Kunihiro Yoshioka
    Ryoichi Tanaka
    Kenta Muranaka
    Tadashi Sasaki
    Takanori Ueda
    Takuya Chiba
    Kouta Takeda
    Tsuyoshi Sugawara
    The International Journal of Cardiovascular Imaging, 2015, 31 : 51 - 58
  • [2] Subtraction coronary CT angiography using second-generation 320-detector row CT
    Yoshioka, Kunihiro
    Tanaka, Ryoichi
    Muranaka, Kenta
    Sasaki, Tadashi
    Ueda, Takanori
    Chiba, Takuya
    Takeda, Kouta
    Sugawara, Tsuyoshi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 51 - 58
  • [3] Subtraction Coronary CT Angiography for the Evaluation of Severely Calcified Lesions Using a 320-Detector Row Scanner
    Yoshioka K.
    Tanaka R.
    Current Cardiovascular Imaging Reports, 2011, 4 (6) : 437 - 446
  • [4] Diagnostic Performance Of 320-Detector Row CT Coronary Angiography: a Comparison with Invasive Angiography
    Nasis, Arthur
    Leung, Michael C.
    Antonis, Paul R.
    Cameron, James D.
    Meredith, Ian T.
    Moir, William S.
    Hope, Sarah A.
    Troupis, John M.
    Crossett, Marcus P.
    Seneviratne, Sujith K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 68D - 68D
  • [5] CT coronary angiography: 256-slice and 320-detector row scanners
    Hsiao E.M.
    Rybicki F.J.
    Steigner M.
    Current Cardiology Reports, 2010, 12 (1) : 68 - 75
  • [6] The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography
    Tatsugami, F.
    Matsuki, M.
    Nakai, G.
    Inada, Y.
    Kanazawa, S.
    Takeda, Y.
    Morita, H.
    Takada, H.
    Yoshikawa, S.
    Fukumura, K.
    Narumi, Y.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : E378 - E382
  • [7] 320-Detector row CT angiography for detection and evaluation of intracranial aneurysms: Comparison with conventional digital subtraction angiography
    Wang, H.
    Li, W.
    He, H.
    Luo, L.
    Chen, C.
    Guo, Y.
    CLINICAL RADIOLOGY, 2013, 68 (01) : E15 - E20
  • [8] Superior CT coronary angiography image quality at lower radiation exposure with second generation 320-detector row CT in patients with elevated heart rate: a comparison with first generation 320-detector row
    Wong, Dennis T. L.
    Soh, Siang Y.
    Ko, Brian S. H.
    Cameron, James D.
    Crossett, Marcus
    Nasis, Arthur
    Troupis, John
    Meredith, Ian T.
    Seneviratne, Sujith K.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (04) : 299 - 306
  • [9] Dynamic CT Angiography and CT Perfusion Employing a 320-Detector Row CT
    Salomon, Eric J.
    Barfett, Joe
    Willems, Peter W. A.
    Geibprasert, Sasikhan
    Bacigaluppi, Susanna
    Krings, Timo
    CLINICAL NEURORADIOLOGY, 2009, 19 (03) : 187 - 196
  • [10] Whole-brain CT digital subtraction angiography of cerebral dural arteriovenous fistula using 320-detector row CT
    Hirokazu Fujiwara
    Suketaka Momoshima
    Takenori Akiyama
    Sachio Kuribayashi
    Neuroradiology, 2013, 55 : 837 - 843