On-line monitoring of the photocatalytic degradation of 2,4-D and dicamba using a solid-phase extraction-multisyringe flow injection system

被引:14
|
作者
Chavez-Moreno, Carmin [1 ]
Ferrer, Laura [2 ]
Hinojosa-Reyes, Laura [1 ]
Hernandez-Ramirez, Aracely [1 ]
Cerda, Victor [3 ]
Guzman-Mar, Jorge [1 ]
机构
[1] UANL, Fac Ciencias Quim, San Nicolas De Los Garza 66451, Nuevo Leon, Mexico
[2] Univ Balearic Isl, Lab Environm Radioact LaboRA, E-07122 Palma De Mallorca, Spain
[3] Univ Balearic Isl, Lab Environm Analyt Chem LQA, E-07122 Palma De Mallorca, Spain
关键词
Dicamba; 2,4-D; Photocatalytic degradation; TiO2; MSFIA system; On-line monitoring; LIQUID-CHROMATOGRAPHY; WATER; ACID; CONTAMINANTS; SUSPENSIONS; RESIDUES; STATE;
D O I
10.1016/j.jenvman.2013.08.007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A fully automated on-line system for monitoring the photocatalytic degradation of herbicides was developed using multisyringe flow injection analysis (MSFIA) coupled to a solid phase extraction (SPE) unit with UV detection. The calibration curves were linear in the concentration range of 100-1000 mu g L-1 for 3,6-dichloro-2-methoxybenzoic acid (dicamba) and 500-3000 mu g L-1 for 2,4-dichlorophenoxyacetic acid (2,4-D), while the detection limits were 30 and 135 mu g L-1 for dicamba and 2,4-D, respectively. The monitoring of the photocatalytic degradation (TiO2 anatase/UV 254 nm) of these two herbicides was performed by MSFIA-SPE system using a small sample volume (2 mL) in a fully automated approach. The degradation was assessed in ultrapure and drinking water with initial concentrations of 1000 and 2000 mu g L-1 for dicamba and 2,4-D, respectively. Degradation percentages of approximately 85% were obtained for both herbicides in ultrapure water after 45 min of photocatalytic treatment. A similar degradation efficiency in drinking water was observed for 2,4-D, whereas dicamba exhibited a lower degradation percentage (75%), which could be attributed to the presence of inorganic species in this kind of water. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 5 条
  • [1] Multisyringe flow injection spectrofluorimetric determination of warfarin at trace levels with on-line solid-phase preconcentration
    de Armas, G
    Miró, M
    Estela, JM
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) : 13 - 23
  • [2] Atrazine and 2, 4-D Determination in Corn Samples Using Microwave Assisted Extraction and On-line Solid-phase Extraction Coupled to Liquid Chromatography
    Susana Santos-Hernandez, Ana
    Hinojosa-Reyes, Laura
    del Carmen Saenz-Tavera, Isabel
    Hernandez-Ramirez, Aracely
    Luis Guzman-Mar, Jorge
    JOURNAL OF THE MEXICAN CHEMICAL SOCIETY, 2018, 62 (02) : 282 - 294
  • [3] On-line molecular imprinted solid-phase extraction flow-injection fluorescence sensor for determination of florfenicol in animal tissues
    Ge, Shenguang
    Yan, Mei
    Cheng, Xiaoliang
    Zhang, Congcong
    Yu, Jinghua
    Zhao, Peini
    Gao, Weigiang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (04) : 615 - 619
  • [4] Sequential Injection Analysis System Exploiting On-line Solid-phase Extraction for the Determination of Strontium and Nickel by Microwave Plasma Atomic Emission Spectrometry
    Ayala, Alejandro
    Takagai, Yoshitaka
    ANALYTICAL SCIENCES, 2018, 34 (03) : 387 - 390
  • [5] Flow injection analysis-flame atomic absorption spectrometry system for indirect determination of sulfite after on-line reduction of solid-phase manganese (IV) dioxide reactor
    Zare-Dorabei, Rouholah
    Boroun, Shokoufeh
    Noroozifar, Meissam
    TALANTA, 2018, 178 : 722 - 727