Application of a new water-soluble polyethylenimine polymer sorbent for simultaneous separation and preconcentration of trace amounts of copper and manganese and their determination by atomic absorption spectrophotometry

被引:37
作者
Sabermahani, F [1 ]
Taher, MA [1 ]
机构
[1] Shahid Bahonar Univ Kerman, Dept Chem, Kerman, Iran
关键词
new water-soluble polyethylenimine polymer sorbent s; simultaneous separation and preconcentration; copper and manganese; atomic absorption spectroscopy;
D O I
10.1016/j.aca.2006.02.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a water-soluble polymer, polyethylenimine (PEI) was used for the simultaneous separation and preconcentration of trace Cu and Mn prior to their determination by flame atomic absorption spectrometry. For this purpose, the sample and the PEI solution were mixed and the metal-bound polymer was precipitated by adding acetone. The precipitate was separated and dissolved in a minimum amounts of water and aspirated into a flame AAS. By increasing the ratio of the volumes of sample to water used in dissolving the precipitate, the analyte elements were concentrated as needed. The sorption is quantitative in the pH >= 6. Detection limits were 5.2 mu g/L for Cu and 5.4 mu g/L for Mn. This method is simple, fast and precise. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:152 / 156
页数:5