Evaluation of a Ventricular Assist Device System: Stability in a Proton Beam Therapy

被引:10
作者
Gossman, Michael S. [1 ,2 ]
Graham, Joel D. [3 ]
Das, Indra J. [4 ,5 ]
Cheng, Chee-wai [4 ]
Coutinho, Len [4 ]
Tamez, Dan [3 ]
Larose, Jeffrey A. [3 ]
机构
[1] Tristate Reg Canc Ctr, Dept Radiat Oncol, Med Phys Sect, Ashland, KY 41101 USA
[2] Regulat Direct Med Phys LLC, Flatwoods, KY USA
[3] HeartWare Inc, Miami Lakes, FL USA
[4] Indiana Univ, Hlth Proton Therapy Ctr, Bloomington, IN 47405 USA
[5] Indiana Univ Sch Med, Dept Radiat Oncol, Indianapolis, IN USA
关键词
left ventricular assist device; HeartWare left ventricular assist device; radiation; ventricular assist device; proton beam treatment; NEUTRON DOSE-EQUIVALENT; CELL LUNG-CANCER; CARDIAC-PACEMAKERS; LATEST GENERATION; RADIOTHERAPY;
D O I
10.1097/MAT.0b013e31826feeca
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inadequate research exists regarding testing of a ventricular assist device (VAD) for susceptibility to radiation damage. Specifically, minimal data are available to radiation oncologists prescribing treatment plans for patients with an implanted VAD. As the number of implanted devices increases, patients requiring radiation at tissue sites near or at the device will increase. The purpose of this study is to provide the first analysis of radiation effects of proton beams on VADs. Five left VAD (LVAD) pumps (HeartWare Inc., Miami Lakes, FL) were exposed to proton beam radiation at a calibrated dose rate of 5 Gy/min up to a cumulative dose of 70 Gy. The HeartWare LVAD pump recorded parameters including power (W), speed (revolutions/min), and estimated flow (L/min). Analysis of collected data after each irradiation found no deviation in pump parameters from baseline values. The HeartWare LVAD pump exhibited no change in device function when directly irradiated by a high energy proton beam. Secondary neutron fluence created in the proton beam during irradiation had no effect on external components including the system controller and batteries powering the HeartWare LVAD. ASAIO Journal 2012;58:597-600.
引用
收藏
页码:597 / 600
页数:4
相关论文
共 22 条
[21]   Cancer-radiotherapy equipment as a cause of soft errors in electronic equipment [J].
Wilkinson, JD ;
Bounds, C ;
Brown, T ;
Gerbi, BJ ;
Peltier, J .
IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2005, 5 (03) :449-451
[22]   High-dose radiotherapy exposure to cardiac pacemakers may be safe in selected patients [J].
Zaremba, Tomas ;
Thogersen, Anna Margrethe ;
Eschen, Ole ;
Hjortshoj, Soren Pihlkjaer ;
Jakobsen, Annette Ross ;
Riahi, Sam .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (01) :133-134