Prospective evaluation of aerosol delivery by a powered nasal nebulizer in the cadaver model

被引:23
|
作者
Manes, R. Peter [2 ]
Tong, Liyue [3 ]
Batra, Pete S. [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Otolaryngol Head & Neck Surg, Comprehens Skull Base Program, Dallas, TX 75390 USA
[2] Yale Univ, Sch Med, Sect Otolaryngol, New Haven, CT USA
[3] Univ Texas SW Med Ctr Dallas, Dept Clin Sci, Dallas, TX 75390 USA
关键词
chronic sinusitis; drug delivery; nebulizer; sinus surgery; topical therapy; CHRONIC RHINOSINUSITIS; CONTROLLED-TRIAL; SINUS SURGERY; IRRIGATION; THERAPY;
D O I
10.1002/alr.20057
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: The objective of this study was to compare the distribution of aerosol delivered via a powered nasal nebulizer device in 5 fresh frozen-cadaver heads (10 total sides). Methods: Nasoneb (R) (Medinvent, St. Paul, MN) was used to deliver a total volume of 10 mL (9 mL saline and 1 mL of 10% fluorescein). Aerosol distribution was assessed in 3 trials: (1) unoperated nose; (2) post-functional endoscopic sinus surgery (FESS); and (3) post-FESS with endoscopic modified Lothrop procedure (EML). Two independent observers rated the distribution of the fluorescein-dyed saline in the anterior nasal cavity (ANC), olfactory cleft (OC), middle meatus (MM), sphenoethmoid recess (SER), nasopharynx (NP), along with maxillary sinus (MS), ethmoid cavity (EC), sphenoid sinus (SS), frontal sinus (FS), and frontal neo-ostium (F-NEO) in the operated specimens. Results: The nebulizer consistently delivered aerosolized saline to the ANC, MM/EC, and SER/SS across the 3 trials. A statistically significant increase in delivery was noted to the MM (p = 0.044) post-FESS. In addition, a statistically significant increase in delivery to the F-NEO was noted post-FESS with EML (p = 0.001). Multiplicity adjustment done for the FESS group showed statistically superior delivery to the EC vs OC (p = 0.031) and FS (p = 0.02) and to the SS vs FS (p = 0.031). Multiplicity adjustment after FESS with EML improved delivery to the FS, resulting in no statistical difference in aerosol delivery between F-NEO and EC or SS. Conclusion: The nebulizer consistently delivered aerosolized saline to multiple nasal subsites, with improvement in delivery seen to the middle meatal region after FESS and F-NEO after FESS with EML. This may have important implications for the delivery of topical medications to the paranasal sinuses in the postoperative setting. (C) 2011 ARS-AAOA, LLC.
引用
收藏
页码:366 / 371
页数:6
相关论文
共 50 条
  • [1] Irrigation penetration of nasal delivery systems: A cadaver study
    Abadie, Wesley M.
    McMains, Kevin C.
    Weitzel, Erik Kent
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2011, 1 (01) : 46 - 49
  • [2] The Impact of High-Flow Nasal Cannula Device, Nebulizer Type, an Placement on Trans-Nasal Aerosol Drug Delivery
    Li, Jie
    Williams, Lucas
    Fink, James B.
    RESPIRATORY CARE, 2022, 67 (01) : 1 - 8
  • [3] Position of different nebulizer types for aerosol delivery in an adult model of mechanical ventilation
    Hou, Haijia
    Xu, Dongyang
    Dai, Bing
    Zhao, Hongwen
    Wang, Wei
    Kang, Jian
    Tan, Wei
    FRONTIERS IN MEDICINE, 2022, 9
  • [4] In vitro comparison between inspiration synchronized and continuous vibrating mesh nebulizer during trans-nasal aerosol delivery
    Li, Jie
    Wu, Wei
    Fink, James B.
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2020, 8 (01)
  • [5] A NEBULIZER SYSTEM FOR HIGHLY REPRODUCIBLE AEROSOL DELIVERY
    KNOCH, M
    WUNDERLICH, E
    GELDNER, S
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1994, 7 (03): : 229 - 237
  • [6] Fabrication and Characterization of Medical Mesh-Nebulizer for Aerosol Drug Delivery
    Choi, Kyong-Hoon
    Moon, Sang-Hyub
    Park, Su-Kang
    Cho, Guangsup
    Nam, Ki Chang
    Park, Bong Joo
    APPLIED SCIENCES-BASEL, 2018, 8 (04):
  • [7] In vitro evaluation of aerosol drug delivery with and without high flow nasal cannula in children
    Alalwan, Mahmood A.
    Fink, James B.
    Ari, Arzu
    PEDIATRIC PULMONOLOGY, 2019, 54 (12) : 1968 - 1973
  • [8] Effect of driving pressure and nebulizer model on aerosol output during intermittent delivery with a dosimeter
    Alkins, SA
    Hurwitz, KM
    Sierra, A
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2002, 15 (01): : 1 - 6
  • [9] Studies on aerosol delivery of plasmid DNA using a mesh Nebulizer
    Arulmuthu, Eugene R.
    Williams, David J.
    Baldascini, Helen
    Versteeg, Henk K.
    Hoare, Mike
    BIOTECHNOLOGY AND BIOENGINEERING, 2007, 98 (05) : 939 - 955
  • [10] Experimental Evaluation of Perfluorocarbon Aerosol Generation with Two Novel Nebulizer Prototypes
    Aramendia, Inigo
    Fernandez-Gamiz, Unai
    Lopez-Arraiza, Alberto
    Rey-Santano, Carmen
    Mielgo, Victoria
    Jose Basterretxea, Francisco
    Sancho, Javier
    Angel Gomez-Solaetxe, Miguel
    PHARMACEUTICS, 2019, 11 (01):