Micro-particle corrugation, adhesion and inhalation aerosol efficiency

被引:82
作者
Adi, Santoso [1 ]
Adi, Handoko [1 ]
Tang, Patricia [1 ]
Traini, Daniela [1 ]
Chan, Hak-Kim [1 ]
Young, Paul M. [1 ]
机构
[1] Univ Sydney, Fac Pharm, Adv Drug Delivery Grp, Sydney, NSW 2006, Australia
关键词
dry powder inhaler; particle corrugation; DPI; AFM; particle adhesion;
D O I
10.1016/j.ejps.2008.05.009
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Atomic force microscopy (AFM) was used to evaluate the particle adhesion and surface morphology of engineered particles for dry powder inhaler (DPI) respiratory therapy to gain a greater understanding of interparticle forces and the aerosolisation process. A series of spherical model drug particles of bovine serum albumin (BSA) was prepared with different degrees of surface corrugation. The particles were evaluated in terms of particle size (laser diffraction) and microscopic morphology (scanning electron microscopy). Conventional tapping mode AFM was used to evaluate the nanoscopic morphology and derive specific roughness parameters, while AFM colloid probe microscopy was used to directly measure the interaction of functionalised probes. The physical characterisation and AFM measurements were evaluated in terms of in vitro aerosolisation performance, using a conventional Rotahaler (R) DPI and multistage liquid impinger. A direct relationship between the root mean square roughness, particle adhesion and in vitro aerosol performance (measured as fine particle fraction, FPF) was observed suggesting that as the degree of corrugation increased, particle adhesion was reduced which, resulted in a concomitant increase in FPF. This study demonstrates that AFM may be used to predict the aerosolisation performance micron sized particles for inhalation based on their morphological properties. (C) 2008 Elsevier B.V All rights reserved.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 22 条
[1]   Predicting mixing performance using surface energy measurements [J].
Ahfat, NM ;
Buckton, G ;
Burrows, R ;
Ticehurst, MD .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1997, 156 (01) :89-95
[2]  
Begat P., 2005, Kona Powder Part J, V23, P109, DOI [DOI 10.14356/KONA.2005014, 10.14356/kona.2005014]
[3]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[4]   Dry powder aerosol drug delivery - Opportunities for colloid and surface scientists [J].
Chan, Hak-Kim .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2006, 284 :50-55
[5]   PHYSICOCHEMICAL CHARACTERIZATION OF A NEW RESPIRABLE FORM OF NEDOCROMIL [J].
CHAN, HK ;
GONDA, I .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1995, 84 (06) :692-696
[6]  
Chan HK, 2006, J AEROSOL MED, V19, P21, DOI 10.1089/jam.2006.19.21
[7]   AERODYNAMIC PROPERTIES OF ELONGATED PARTICLES OF CROMOGLYCIC ACID [J].
CHAN, HK ;
GONDA, I .
JOURNAL OF AEROSOL SCIENCE, 1989, 20 (02) :157-&
[8]   How much particle surface corrugation is sufficient to improve aerosol performance of powders? [J].
Chew, NYK ;
Tang, P ;
Chan, HK ;
Raper, JA .
PHARMACEUTICAL RESEARCH, 2005, 22 (01) :148-152
[9]   Use of solid corrugated particles to enhance powder aerosol performance [J].
Chew, NYK ;
Chan, HK .
PHARMACEUTICAL RESEARCH, 2001, 18 (11) :1570-1577
[10]   Hollow porous particles in metered dose inhalers [J].
Dellamary, LA ;
Tarara, TE ;
Smith, DJ ;
Woelk, CH ;
Adractas, A ;
Costello, ML ;
Gill, H ;
Weers, JG .
PHARMACEUTICAL RESEARCH, 2000, 17 (02) :168-174