Long-term on-site assessment of hygrothermal performance of interior thermal insulation system without water vapour barrier

被引:67
作者
Toman, Jan [1 ]
Vimmrova, Alena [1 ]
Cerny, Robert [1 ]
机构
[1] Czech Tech Univ, Fac Civil Engn, Dept Mat Engn & Chem, Prague 16629 6, Czech Republic
关键词
Brick wall; Interior thermal insulation system; Hydrophilic mineral wool; Water vapour retarder; Hygrothermal performance; On-site assessment; MOISTURE;
D O I
10.1016/j.enbuild.2008.07.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
On-site assessment of hygric and thermal performance of an interior thermal insulation system on the basis of hydrophilic mineral wool is presented in the paper. The system is applied during the Summer period oil a brick-built house from the end of 19th century. Hygrothermal testing is done during the time period of 4 years. The reconstructed building envelope exhibits very good hygrothermal performance. The thermal resistance increases approximately two times. Water condensation is never observed inside the envelope during the whole testing period. A comparison with the previous experiment in semi-scale conditions which was performed for similar insulation system constructed during the winter season shows that the precedence should be given to the application of the system in summer period as it is more considerate to the old masonry. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 18 条
[1]   Transient analysis of an external building cladding [J].
Balocco, C. ;
Grazzini, G. ;
Cavalera, A. .
ENERGY AND BUILDINGS, 2008, 40 (07) :1273-1277
[2]  
Cerny R, 2001, ADV ARC SER, V13, P405
[3]  
CERNY R, 2001, P INT C BUILD ENV SY, P251
[4]   Effect of hydrophilic admixtures on moisture and heat transport and storage parameters of mineral wool [J].
Jiricková, M ;
Cerny, R .
CONSTRUCTION AND BUILDING MATERIALS, 2006, 20 (06) :425-434
[5]  
JIRICKOVA M, 2002, P 11 S BUILD PHYS TU, P319
[6]   Hygrothermal system-performance of a whole building [J].
Karagiozis, A ;
Salonvaara, M .
BUILDING AND ENVIRONMENT, 2001, 36 (06) :779-787
[7]   The impact of temperature and moisture on the thermal performance of stone wool [J].
Karamanos, A. ;
Hadiarakou, S. ;
Papadopoulos, A. M. .
ENERGY AND BUILDINGS, 2008, 40 (08) :1402-1411
[8]   Influence of insulation configuration on heating and cooling loads in a continuously used building [J].
Kossecka, E ;
Kosny, J .
ENERGY AND BUILDINGS, 2002, 34 (04) :321-331
[9]   Effect of interior and exterior insulation on the hygrothermal behaviour of exposed walls [J].
Kunzel, HM .
MATERIALS AND STRUCTURES, 1998, 31 (206) :99-103
[10]  
MADERA J, 2002, BUILDING RES J, V50, P225