Dispatch modeling of a regional power generation system - Integrating wind power

被引:53
作者
Goransson, Lisa [1 ]
Johnsson, Filip [1 ]
机构
[1] Chalmers, Environm & Energy Dept, S-41296 Gothenburg, Sweden
关键词
Wind power; Integration; Dispatch; Generation; Modeling; AIR ENERGY-STORAGE; ELECTRICITY;
D O I
10.1016/j.renene.2008.08.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A modeling tool has been developed which can be used to analyze interaction between intermittent wind power generation and thermal power plant generation in a regional electricity grid system. The model uses a mixed integer programming (MIP) approach to determine the power plant dispatch strategy which yields the lowest systems costs. In the model, each large thermal plant is described separately, including properties such as start-up time, start-up cost and minimum load level. The model is evaluated using western Denmark as a case study. For western Denmark, it is found that the inclusion of start-up performance (i.e. start-up time and related costs) and minimum load level of the power generating units have a significant impact on the results. It is shown that the inclusion of these aspects influences the analysis of the effect of wind power variations on the production patterns of thermal units in the system. The model demonstrates how the introduction of wind power production and associated variations change the dispatch order of the large thermal power plants in the western Denmark system so that the unit with the lowest running costs no longer has the highest capacity factor. It is shown that this effect only is detected if start-up performance and minimum load level limitations are included in the optimization. it can also be concluded that start-up performance and minimum load level must be taken into account if the total system costs and emissions are not to be underestimated. The simulations show that if these aspects are disregarded, both total costs and total emissions of the power system are underestimated, with 5% in the case of western Denmark. Models such as the one developed in this work can be efficient tools to understand the effects of large-scale wind power integration in a power generation system with base load plants. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1040 / 1049
页数:10
相关论文
共 15 条
[1]  
[Anonymous], P 4 INT WORKSH LARG
[2]  
[Anonymous], 2007, EA ENERGY ANAL 50 WI
[3]   Optimal operation and hydro storage sizing of a wind-hydro power plant [J].
Castronuovo, ED ;
Lopes, JAP .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2004, 26 (10) :771-778
[4]   Controllable and affordable utility-scale electricity from intermittent wind resources and compressed air energy storage (CAES) [J].
Cavallo, Alfred .
ENERGY, 2007, 32 (02) :120-127
[5]   Quantifying the total net benefits of grid integrated wind [J].
Denny, Eleanor ;
O'Malley, Mark .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (02) :605-615
[6]  
*ELTR, 2005, PUDDEL PROJ SLUTR
[7]  
Eriksen P. B., 2005, IEEE Power & Energy Magazine, V3, P65, DOI 10.1109/MPAE.2005.1524622
[8]   Economic and environmental dispatch of power/CHP production systems [J].
Eriksen, PB .
ELECTRIC POWER SYSTEMS RESEARCH, 2001, 57 (01) :33-39
[9]   Baseload wind energy: modeling the competition between gas turbines and compressed air energy storage for supplemental generation [J].
Greenblatt, Jeffery B. ;
Succar, Samir ;
Denkenberger, David C. ;
Williams, Robert H. ;
Socolow, Robert H. .
ENERGY POLICY, 2007, 35 (03) :1474-1492
[10]  
Gross R., 2006, The Costs and Impacts of Intermittency: An assessment of the evidense on the costs and impacts of intermittent generation on the British electricity network