A new method for extracting spanwise vortex from 2D particle image velocimetry data in open-channel flow

被引:2
|
作者
Zhang, Peng [1 ]
Yang, Shengfa [2 ]
Hu, Jiang [2 ]
Li, Wenjie [2 ]
Fu, Xuhui [2 ]
Li, Danxun [1 ]
机构
[1] Tsinghua Univ, State Key Lab Hydrosci & Engn, Beijing 100084, Peoples R China
[2] Chongqing Jiaotong Univ, Natl Inland Waterway Regulat Engn Res Ctr, Chongqing 400074, Peoples R China
基金
中国国家自然科学基金;
关键词
Vortex identification; Spanwise vortex; Vorticity filtering; Open-channel flow; TURBULENT-BOUNDARY-LAYER; OUTER REGION; IDENTIFICATION; VORTICES; SURFACE; MOTIONS;
D O I
10.2478/johh-2020-0020
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The two-dimensional particle image velocimetry (PIV) data are inevitably contaminated by noise due to various imperfections in instrumentation or algorithm, based on which the well-established vortex identification methods often yield noise or incomplete vortex structure with a jagged boundary. To make up this deficiency, a novel method was proposed in this paper and the efficiency of the new method was demonstrated by its applications in extracting the two-dimensional spanwise vortex structures from 2D PIV data in open-channel flows. The new method takes up a single vortex structure by combining model matching and vorticity filtering, and successfully locates the vortex core and draws a streamlined vortex boundary. The new method shows promise as being more effective than commonly used schemes in open-channel flow applications.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 50 条
  • [21] Stereoscopic particle image velocimetry investigation of three-dimensional characteristics of vortex structure in a turbulent channel flow
    Li, FC
    Kawaguchi, Y
    Segawa, T
    Hishida, K
    CHINESE PHYSICS LETTERS, 2005, 22 (03) : 624 - 627
  • [22] Experimental evaluation of 2-D entropy model for open-channel flow
    de Araujo, JC
    Chaudhry, FH
    JOURNAL OF HYDRAULIC ENGINEERING, 1998, 124 (10) : 1064 - 1067
  • [23] Implementation of vibration correction schemes to the evaluation of a turbulent flow in an open channel by tomographic particle image velocimetry
    Earl, T. A.
    Cochard, S.
    Thomas, L.
    Tremblais, B.
    David, L.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (01)
  • [24] Experimental Investigation of Vortex Structures in Wake of Hyperboloid-Shaped Model by Means of 2D Particle Image Velocimetry Measurement
    Barraclough, V.
    Novotny, J.
    Safarik, P.
    EFM17 - EXPERIMENTAL FLUID MECHANICS 2017, 2018, 180
  • [25] Simulating dynamic stall in a 2D VAWT: Modeling strategy, verification and validation with particle image Velocimetry data
    Ferreira, C. J. Simao
    Bijl, H.
    van Bussel, G.
    van Kuik, G.
    SCIENCE OF MAKING TORQUE FROM WIND, 2007, 75
  • [26] DPIVSoft-OpenCL: A multicore CPU–GPU accelerated open-source code for 2D Particle Image Velocimetry
    Aguilar-Cabello, Jorge
    Parras, Luis
    del Pino, Carlos
    SoftwareX, 2022, 20
  • [27] A 2D immersed interface Vortex Particle-Mesh method
    Gillis, T.
    Marichal, Y.
    Winckelmans, G.
    Chatelain, R.
    JOURNAL OF COMPUTATIONAL PHYSICS, 2019, 394 : 700 - 718
  • [28] Modelling of 2D flows in complex geometry by the vortex particle method
    Kudela, Henryk
    Malecha, Ziemowit Milosz
    INZYNIERIA CHEMICZNA I PROCESOWA, 2006, 27 (03): : 707 - 719
  • [29] Simulation of 2D surface flow in open channel using explicit finite difference method
    Kamboh, Shakeel Ahmed
    Sarbini, Izzatul Nabila Bt
    Labadin, Jane
    2015 9TH INTERNATIONAL CONFERENCE ON IT IN ASIA (CITA), 2015,
  • [30] Computing viscous flow along a 2D open channel using the immersed interface method
    Patterson, Sarah E.
    Layton, Anita T.
    ENGINEERING REPORTS, 2021, 3 (05)