A Cone-Beam Computed Tomography Triple Scan Procedure to Obtain a Three-Dimensional Augmented Virtual Skull Model Appropriate for Orthognathic Surgery Planning

被引:160
作者
Swennen, Gwen R. J. [1 ,2 ,3 ]
Mollemans, Woluer [4 ]
De Clercq, Calix [1 ,2 ,3 ]
Abeloos, Johan [1 ,2 ,3 ]
Lamoral, Philippe [1 ,2 ,3 ]
Lippens, Frank [1 ,2 ,3 ]
Neyl, Nathalie [1 ,2 ,3 ]
Casselman, Jan [2 ,3 ,5 ]
Schutyser, Filip [2 ,3 ,4 ]
机构
[1] Gen Hosp St Jan Bruges, Dept Surg, Div Maxillofacial Surg, B-8000 Brugge, Belgium
[2] 3D Facial Imaging Res Grp, Brugge, Belgium
[3] Radboud Univ Nijmegen, NL-6525 ED Nijmegen, Netherlands
[4] Univ Hosp Gasthuisberg, Fac Med & Engn, Med Image Comp Radiol ESAT PSI, B-3000 Louvain, Belgium
[5] Gen Hosp St Jan Bruges, Dept Radiol & Med Imaging, Brugge, Belgium
关键词
Three-dimensional imaging; diagnosis; computerized tomography; maxillofacial surgery; dental occlusion; IMAGE REGISTRATION; SPLINT;
D O I
10.1097/SCS.0b013e3181996803
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan procedure with triple voxel-based rigid registration was evaluated and validated on 10 orthognathic patients, First, the patient was scanned vertically with a wax bite wafer in place (CBCT scan N degrees 1). Second, a limited dose scan of the patient with a Triple Tray AlgiNot impression in place was carried Out (CBCT scan N degrees 2). Finally. a high-resolution scan of the Triple Tray AlgiNot impression was done (CBCT scan N degrees 3). Sequential and semiautomatic triple voxel-based rigid registration (RN degrees 1-RN degrees 3) was performed to augment the patient's skull model with accurate occlusal and intercuspidation data (Maxilim, version 2.1.1.. Medicim NV Mechelen, Belgium). All registrations were based oil the Maximisation of Mutual Information registration algorithm. Because the accuracy and stability of the voxel-based registration (RN degrees 1) between the Triple Tray AlgiNot impression scan and the limited low-dose patient scan were not known, this particular registration step needed to be validated. The accuracy of registration was measured on a synthetic skull and showed to be highly accurate. A volume overlap of 98.1% was found for registered impression scan N degrees 1. The mean distance between registered impression scan N degrees 1 and registered impression scan N degrees 2 was 0.08 +/- 0.0.3 mm (range, 0.04-0.11 mm). As far as the stability of registration was concerned, Successful registration with a stable optimal position was obtained with a maximum variability of less than 0.1 mm. The results of this study showed that semiautomatic sequential triple voxel-based rigid registration of the triple CBCT scans augmented the 3-D virtual skull model with detailed occlusal and intercuspidation data in a highly accurate and robust way. The method is therefore appropriate and valid for 3-D virtual orthognathic Surgery planning in the clinical routine.
引用
收藏
页码:297 / 307
页数:11
相关论文
共 18 条
  • [1] Farkas LG., 1994, ANTHROPOMETRY HEAD F
  • [2] A new technique for the creation of a computerized composite skull model
    Gateno, J
    Xia, J
    Teichgraeber, JF
    Rosen, A
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (02) : 222 - 227
  • [3] 3-DIMENSIONAL CRANIOFACIAL SURGERY - TRANSFER FROM A 3-DIMENSIONAL MODEL (ENDOPLAN) TO CLINICAL SURGERY - A NEW TECHNIQUE (GRAZ)
    KARCHER, H
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1992, 20 (03): : 125 - 131
  • [4] LAMBRECHT JT, 1995, 3D MODELING TECHNOLO, P61
  • [5] Multimodality image registration by maximization of mutual information
    Maes, F
    Collignon, A
    Vandermeulen, D
    Marchal, G
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 187 - 198
  • [6] Fusion of computed tomography data and optical 3D images of the dentition for streak artefact correction in the simulation of orthognathic surgery
    Nkenke, E
    Zachow, S
    Benz, M
    Maier, T
    Veit, K
    Kramer, M
    Benz, S
    Häusler, G
    Neukam, FW
    Lell, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (04) : 226 - 232
  • [7] The Graz hemisphere splint: a new precise, non-invasive method of replacing the dental arch of 3D-models by plaster models
    Santler, G
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (03) : 169 - 173
  • [8] SCHIEL HJ, 1996, J CRANIOMAXILLOFAC S, V24, P102
  • [9] Schutyser F, 2005, LECT NOTES COMPUT SC, V3749, P368
  • [10] The use of a new 3D splint and double CT scan procedure to obtain an accurate anatomic virtual augmented model of the skull
    Swennen, G. R. J.
    Barth, E. -L.
    Eulzer, C.
    Schutyser, F.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 36 (02) : 146 - 152