Comparison of micellar electrokinetic capillary chromatographic method with high-performance liquid chromatographic method for the determination of imidazolidine-2-thione (ethylenethiourea) in formulated products

被引:7
|
作者
Lo, CC [1 ]
Hsiao, YM [1 ]
机构
[1] TAIWAN AGR CHEM & TOX SUBST RES INST,DEPT PESTICIDE CHEM,TAICHUNG,TAIWAN
关键词
MECC; HPLC; ETU; sensitivity; column efficiency; precision; accuracy; solvent volume;
D O I
10.1021/jf960655c
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A micellar electrokinetic capillary chromatographic (MECC) method was developed for routine analysis of the carcinogenic compound imidazolidine-2-thione (ETU) in commercial ethylenebis-(dithiocarbamate) fungicides (EBDC). The MECC method was compared with a previously developed high-performance liquid chromatographic (HPLC) method. Both methods demonstrated good precision, accuracy, linearity, and sensitivity. The relative standard deviations (RSD) for precision ranged from 0.04 to 5.09% for the MECC method and from 0.47-5.22% for the HPLC method. The recoveries for accuracy ranged from 98.3 to 100.6% for the MECC method and from 99.5 to 104.9% for the HPLC method. No matrix interference was observed in either method. The column efficiency of MECC (N = 12491) was 15 times higher than that of HPLC (N = 813). The instrument detection limit (IDL) and the method detection limit (MDL) of the MECC method were 0.25 and 0.30 mu g/mL, which were 25 and 15 times higher than the IDL (0.01 mu g/mL) and the MDL (0.02 mu g/mL) of the HPLC method, respectively. The most important advantages of the MECC method over the HPLC method are the shorter run time and the reduction in solvent waste. The total run times for analyzing a sample were 11 min for the MECC method and 15 min for the HPLC method, and the volume of waste solvent for the MECC method (49.0 mu L/sample) was 153 times less than that for the HPLC method (7.5 mL/sample). This research has proven that the routine ETU analysis in formulated EBDC products by the MECC method is comparable with traditional the HPLC method and the MECC method is better than the HPLC method if the run time and the cost of solvent are considered.
引用
收藏
页码:3118 / 3122
页数:5
相关论文
共 50 条
  • [31] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF TIFLAMIZOLE IN PLASMA
    RAKESTRAW, DC
    WHITNEY, CC
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (12) : 1829 - 1830
  • [32] Development of a new high-performance liquid chromatographic method for the determination of ceftazidime
    De Haro Moreno, Andréia
    Salgado, Hérida Regina Nunes
    Journal of AOAC International, 1600, 91 (04): : 739 - 743
  • [33] Rapid high-performance liquid chromatographic method for the determination of peroxyacetic acid
    Pinkernell, U
    Effkemann, S
    Nitzsche, F
    Karst, U
    JOURNAL OF CHROMATOGRAPHY A, 1996, 730 (1-2) : 203 - 208
  • [34] High-performance liquid chromatographic method for the determination of gabapentin in human plasma
    Zhu, Z
    Neirinck, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 779 (02): : 307 - 312
  • [35] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF METOCLOPRAMIDE IN PLASMA
    SHIELDS, BJ
    MACKICHAN, JJ
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (13): : 2643 - 2659
  • [36] A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF POLYPHOSPHOINOSITIDES IN BRAIN
    NAKAMURA, T
    HATORI, Y
    YAMADA, K
    IKEDA, M
    YUZURIHA, T
    ANALYTICAL BIOCHEMISTRY, 1989, 179 (01) : 127 - 130
  • [37] A new high-performance liquid chromatographic method for determination of warfarin enantiomers
    Osman, A
    Arbring, K
    Lindahl, TL
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 826 (1-2): : 75 - 80
  • [38] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CEFPIMIZOLE IN TISSUE
    FRIIS, JM
    LAKINGS, DB
    JOURNAL OF CHROMATOGRAPHY, 1986, 382 : 399 - 404
  • [39] High-Performance Liquid Chromatographic Method for the Determination of Nimesulide in Pharmaceutical Preparations
    B. S. Nagaralli
    J. Seetharamappa
    B. G. Gowda
    M. B. Melwanki
    Journal of Analytical Chemistry, 2003, 58 : 778 - 780
  • [40] A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF PLASMA METHOTREXATE
    BERNHARDT, JA
    BRIDGES, RA
    CLINICAL CHEMISTRY, 1981, 27 (06) : 1088 - 1088