99mTc-Radiolabeled TPGS Nanomicelles Outperform 99mTc-Sestamibi as Breast Cancer Imaging Agent

被引:3
|
作者
Tesan, Fiorella C. [1 ]
Nicoud, Melisa B. [2 ]
Nunez, Mariel [1 ]
Medina, Vanina A. [2 ]
Chiappetta, Diego A. [3 ,4 ]
Salgueiro, Maria J. [1 ]
机构
[1] Univ Buenos Aires, Fac Farm & Bioquim, Catedra Fis, Buenos Aires, DF, Argentina
[2] UCA, Consejo Nacl Invest Cient & Tecn, CONICET, Lab Biol Tumoral & Inflamac,Inst Invest Biomed BI, Buenos Aires, DF, Argentina
[3] Consejo Nacl Invest Cient & Tecn, Buenos Aires, DF, Argentina
[4] Univ Buenos Aires, Fac Farm & Bioquim, Catedra Tecnol Farmaceut 1, Buenos Aires, DF, Argentina
关键词
D O I
10.1155/2019/4087895
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
D-alpha-Tocopheryl polyethylene glycol 1000 succinate (TPGS) is a Food and Drug Administration (FDA) approved biomaterial that can form nanosized micelles in aqueous solution. TPGS micelles stand as an interesting system to perform drug delivery as they can carry lipophilic drugs and overcome P glycoprotein efflux as well. Therefore, TPGS micelles combined with other copolymers have been reported in many cancer research studies as a carrier for therapeutic drugs. Their ability to reach tumoral tissue can also be exploited to develop imaging agents with diagnostic application. A radiolabeling method with Tc-99m for TPGS nanosized micelles and their biodistribution in a healthy animal model as well as their pharmacokinetics and radiolabeling stability in vivo was previously reported. The aim of this work was to evaluate the performance of this radioactive probe as a diagnostic imaging agent compared to routinely available SPECT radiopharmaceutical, Tc-99m-sestamibi. A small field of view gamma camera was used for scintigraphy studies using radiolabeled TPGS micelles in two animal models of breast cancer: syngeneic 4T1 murine cell line (injected in BALB/c mice) and chemically NMU-induced (Sprague-Dawley rats). Ex vivo radioactivity accumulation in organs of interest was measured by a solid scintillation counter, and a semiquantitative analysis was performed over acquired images as well. Results showed an absence of tumoral visualization in 4T1 model for both radioactive probes by gamma camera imaging. On the contrary, NMU-induced tumors had a clear tumor visualization by scintigraphy. A higher tumor/background ratio and more homogeneous uptake were found for radiolabeled TPGS micelles compared to Tc-99m-sestamibi. In conclusion, Tc-99m-radiolabeled TPGS micelles might be a potential SPECT imaging probe for diagnostic purposes.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Evaluation of lymphoma in a cat using 99mTc-sestamibi
    Lenard, ZM
    Zuber, RM
    Nicoll, RG
    O'Hara, AJ
    Lester, NV
    VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (06) : 533 - 535
  • [42] Predictive value of 99mTc-sestamibi (99mTc-MIBI) in patients with multiple myeloma (MM)
    Pace, L
    Catalano, L
    Del Vecchio, S
    De Renzo, A
    Tedesco, N
    Califano, C
    Annunziata, G
    Di Gennaro, F
    Rotoli, B
    Salvatore, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1253 - 1253
  • [43] From 201Tl to 99mTc-Sestamibi
    Schwaiger, Markus
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 : 110S - 111S
  • [44] Sensitivity and specificity of planar scintimammography with 99mTc-sestamibi
    Danielsson, R
    Boné, B
    Gad, A
    Sylvan, M
    Aspelin, P
    ACTA RADIOLOGICA, 1999, 40 (04) : 394 - 399
  • [45] Pharmacokinetic model of myocardial 99mTc-sestamibi washout
    Tsubasa Watanabe
    Hajime Monzen
    Masatake Hara
    Takashi Mizowaki
    Masahiro Hiraoka
    Annals of Nuclear Medicine, 2013, 27 : 279 - 284
  • [46] Efficiency comparison between 99mTc-tetrofosmin and 99mTc-sestamibi myocardial perfusion studies
    Ravizzini, GC
    Hanson, MW
    Shaw, LK
    Wong, TZ
    Hagge, RJ
    Pagnanelli, RA
    Jain, D
    Lima, HS
    Coleman, RE
    Borges-Neto, S
    NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (03) : 203 - 208
  • [47] 99mTc-Tetrofosmin or 99mTc-Sestamibi for double-phase parathyroid scintigraphy.
    Fröberg, AC
    Valkema, R
    Bonjer, HJ
    Krenning, EP
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 326P - 326P
  • [48] Breast-specific gamma imaging with 99mTc-Sestamibi and magnetic resonance Imaging in the diagnosis of breast cancer -: A comparative study
    Brem, Rachel F.
    Petrovitch, Ivan
    Rapelyea, Jocelyn A.
    Young, Heather
    Teal, Christine
    Kelly, Tricia
    BREAST JOURNAL, 2007, 13 (05): : 465 - 469
  • [49] Efficacy of 99mTc-sestamibi SPECT/CT for minimally invasive parathyroidectomy: comparative study with 99mTc-sestamibi scintigraphy, SPECT, US and CT
    Kim, Yong-il
    Jung, Young Ho
    Hwang, Ki Tae
    Lee, Ho-Young
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (10) : 804 - 810
  • [50] Incidental Primary Breast Lymphoma on 99mTc-Sestamibi Myocardial Perfusion Imaging With SPECT/CT
    Deng, Zilong
    Dong, Aisheng
    Zhao, Min
    Tang, Youhong
    Liu, Yutao
    CLINICAL NUCLEAR MEDICINE, 2019, 44 (08) : E492 - E494