摘要
Artificial pancreas (AP) systems, a long-sought quest to replicate mechanically islet physiology that is lost in diabetes, are reaching the clinic, and the potential of automating insulin delivery is about to be realized. Significant progress has been made, and the safety and feasibility of AP systems have been demonstrated in the clinical research center and more recently in outpatient "real-world" environments. An iterative road map to AP system development has guided AP research since 2009, but progress in the field indicates that it needs updating. While it is now clear that AP systems are technically feasible, it remains much less certain that they will be widely adopted by clinicians and patients. Ultimately, the true success of AP systems will be defined by successful integration into the diabetes health care system and by the ultimate metric: improved diabetes outcomes.
引用
收藏
页码:1036 / 1043
页数:8
相关论文
共 45 条
  • [1] [Anonymous], MMW MUNCH MED WOCHEN
  • [2] [Anonymous], DIABETES TECHNOL S1
  • [3] [Anonymous], DIABETES PATIENTS AR
  • [4] [Anonymous], DIABETES TECHNOL THE
  • [5] [Anonymous], TIME MAGAZINE
  • [6] [Anonymous], MEET BIGFOOT FAMILY
  • [7] Factors affecting the success of glucagon delivered during an automated closed-loop system in type 1 diabetes
    Bakhtiani, P. A.
    El Youssef, J.
    Duell, A. K.
    Branigan, D. L.
    Jacobs, P. G.
    Lasarev, M. R.
    Castle, J. R.
    Ward, W. K.
    [J]. JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2015, 29 (01) : 93 - 98
  • [8] The T1D Exchange Clinic Registry
    Beck, Roy W.
    Tamborlane, William V.
    Bergenstal, Richard M.
    Miller, Kellee M.
    DuBose, Stephanie N.
    Hall, Callyn A.
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2012, 97 (12) : 4383 - 4389
  • [9] Threshold-Based Insulin-Pump Interruption for Reduction of Hypoglycemia
    Bergenstal, Richard M.
    Klonoff, David C.
    Garg, Satish K.
    Bode, Bruce W.
    Meredith, Melissa
    Slover, Robert H.
    Ahmann, Andrew J.
    Welsh, John B.
    Lee, Scott W.
    Kaufman, Francine R.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (03) : 224 - 232
  • [10] Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes
    Bode, BW
    Schwartz, S
    Stubbs, HA
    Block, JE
    [J]. DIABETES CARE, 2005, 28 (10) : 2361 - 2366