Numerical Simulation and Analysis for the U-tube Heat Exchanger of Ground Source Heat Pump

被引:0
作者
Chang Zhen [1 ]
Guo Min [1 ]
机构
[1] Beijing Univ Technol, Coll Elect Informat & Control Engn, Beijing 100024, Peoples R China
来源
2013 32ND CHINESE CONTROL CONFERENCE (CCC) | 2013年
关键词
Ground source heat pump; U-pipe heat exchanger; Numerical simulation;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a three-dimensional numerical heat transfer model of the vertical U-tube is established using FLUENT software to research on its unsteady fluid-structure heat transfer process in order to better simulate the heat transfer area of the underground pipes in ground source heat pump system. In winter, the simulation results coincide with the experimental dates. In addition, this paper also analyzes the effects of the flow rate within the pipe, the thermal conductivity of grout, the shank spacing of U-tube and the borehole depth on the heat transfer rate. The simulation results show that the heat transfer of underground pipe per meter is proportional to the flow rate within the pipe, the thermal conductivity of grout and the shank spacing of U-tube, while it has an inverse relationship with the borehole depth.
引用
收藏
页码:8713 / 8717
页数:5
相关论文
共 50 条
  • [1] Numerical simulation and experimental validation of a vertical U-tube ground heat exchanger
    Gao, Yike
    Gao, Yan
    Yu, Yong
    Lin, Xinxing
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 709 - +
  • [2] Performance analysis of a solar-assisted ground source heat pump with a single vertical U-tube ground heat exchanger
    Adebayo, Philip
    Shor, Roman
    Mohamad, Abdulmajeed
    Wemhoner, Carsten
    Mwesigye, Aggrey
    APPLIED THERMAL ENGINEERING, 2024, 257
  • [3] Simulation study on the thermal performance of vertical U-tube heat exchangers for ground source heat pump system
    Pu, Liang
    Qi, Di
    Li, Kang
    Tan, Hongbo
    Li, Yanzhong
    APPLIED THERMAL ENGINEERING, 2015, 79 : 202 - 213
  • [4] Performance evaluation of a vertical U-tube ground heat exchanger using a numerical simulation approach
    Hu, Pingfang
    Yu, Zhongyi
    Lei, Fei
    Zhu, Na
    Sun, Qiming
    Yuan, Xudong
    APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2, 2013, 724-725 : 909 - +
  • [5] Efficiency analysis of utilizing phase change materials as grout for a vertical U-tube heat exchanger coupled ground source heat pump system
    Chen, Fei
    Mao, Jinfeng
    Chen, Shangyuan
    Li, Chaofeng
    Hou, Pumin
    Liao, Lu
    APPLIED THERMAL ENGINEERING, 2018, 130 : 698 - 709
  • [6] Soil temperature distribution around a U-tube heat exchanger in a multi-function ground source heat pump system
    Li, Shuhong
    Yang, Weihua
    Zhang, Xiaosong
    APPLIED THERMAL ENGINEERING, 2009, 29 (17-18) : 3679 - 3686
  • [7] Unified heat transfer model of vertical U-tube heat exchangers for ground source heat pump system
    Zhang, Z.-W. (zwzhang10@126.com), 1600, Tsinghua University (31): : 269 - 274
  • [8] New global thermal numerical model of vertical U-tube ground heat exchanger
    Chwieduk, Michal
    RENEWABLE ENERGY, 2021, 168 : 343 - 352
  • [9] The Numerical Simulation of Ground Source Heat Pump
    Zhang, Jian
    Wang, Ling
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 979 - 982
  • [10] Numerical Simulation of Soil Temperature Field Surrounding Vertical U Tube Heat Exchanger for Ground Coupled Heat Pump
    Bai, Tian
    Zhang, Jianli
    Zheng, Maoyu
    Zhang, Hui
    He, Maoting
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 3, 2009, : 275 - 280