High resolution low-temperature superconductivity superconducting quantum interference device microscope for imaging magnetic fields of samples at room temperatures

被引:40
作者
Baudenbacher, F [1 ]
Peters, NT [1 ]
Wikswo, JP [1 ]
机构
[1] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37235 USA
关键词
D O I
10.1063/1.1448142
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a microscope to image weak magnetic fields using submillimeter pickup coils made from conventional low-temperature superconducting niobium wire coupled to the input circuit of a superconducting quantum interference device (SQUID). The pickup coil and the SQUID sensor are mounted in the vacuum space of the cryostat and are thermally anchored to the liquid helium reservoir. A 25 mum thick sapphire window separates the room temperature (RT) sample and the vacuum space. The spacing between the pickup coil and RT sample was typically less than 130 mum. The spatial resolution is limited by the diameter of the pickup coil. The pickup coils are easily interchangeable, allowing us to adapt the SQUID microscope to a variety of different measurements. We have achieved a spatial resolution of 250 mum with a magnetic field sensitivity of 850 fT/Hz(1/2) or a spatial resolution of 500 mum with a magnetic field sensitivity of 330 fT/Hz(1/2). We have used this instrument to measure various biomagnetic and paleomagnetic fields. (C) 2002 American Institute of Physics.
引用
收藏
页码:1247 / 1254
页数:8
相关论文
共 27 条
[1]   A superconducting quantum interference device magnetometer system for quantitative analysis and imaging of hidden corrosion activity in aircraft aluminum structures [J].
Abedi, A ;
Fellenstein, JJ ;
Lucas, AJ ;
Wikswo, JP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (12) :4640-4651
[2]   MAGNETIC MICROSCOPY USING A LIQUID-NITROGEN COOLED YBA2CU3O7 SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE [J].
BLACK, RC ;
MATHAI, A ;
WELLSTOOD, FC ;
DANTSKER, E ;
MIKLICH, AH ;
NEMETH, DT ;
KINGSTON, JJ ;
CLARKE, J .
APPLIED PHYSICS LETTERS, 1993, 62 (17) :2128-2130
[3]  
BUCHANAN DS, 1990, MICROSQUID CLOSE SPA, P677
[4]  
CHATRAPHORN S, 1999, B AM PHYS SOC, V44, P1554
[5]   A new study of bacterial motion: Superconducting quantum interference device microscopy of magnetotactic bacteria [J].
Chemla, YR ;
Grossman, HL ;
Lee, TS ;
Clarke, J ;
Adamkiewicz, M ;
Buchanan, BB .
BIOPHYSICAL JOURNAL, 1999, 76 (06) :3323-3330
[6]  
CLARKE J, 1996, SQUID FUNDAMENTALS, V329, P1
[7]   JOHNSON NOISE FROM NORMAL METAL NEAR A SUPERCONDUCTING SQUID GRADIOMETER CIRCUIT [J].
CLEM, JR .
IEEE TRANSACTIONS ON MAGNETICS, 1987, 23 (02) :1093-1096
[8]  
Cochran A, 1996, REV PROG Q, V15, P1151
[9]   Low excess flux noise in YBa2Cu3O7-x dc SQUIDs cooled in static magnetic fields [J].
Dantsker, E ;
Tanaka, S ;
Nilsson, PA ;
Kleiner, R ;
Clarke, J .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) :2772-2775
[10]   DESIGN, FABRICATION, AND PERFORMANCE OF INTEGRATED MINIATURE SQUID SUSCEPTOMETERS [J].
KETCHEN, MB ;
AWSCHALOM, DD ;
GALLAGHER, WJ ;
KLEINSASSER, AW ;
SANDSTROM, RL ;
ROZEN, JR ;
BUMBLE, B .
IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (02) :1212-1215