PET Assessment of Epicardial Intimal Disease and Microvascular Dysfunction in Cardiac Allograft Vasculopathy

被引:78
作者
Chih, Sharon [1 ]
Chong, Aun Yeong [2 ]
Erthal, Fernanda [3 ]
deKemp, Robert A. [3 ]
Davies, Ross A. [1 ]
Stadnick, Ellamae [1 ]
So, Derek Y. [2 ]
Overgaard, Christopher [4 ]
Wells, George [5 ]
Mielniczuk, Lisa M. [1 ]
Beanlands, Rob S. B. [3 ]
机构
[1] Univ Ottawa, Inst Heart, Dept Med, Heart Failure & Transplantat,Div Cardiol, Ottawa, ON, Canada
[2] Univ Ottawa, Inst Heart, Dept Med, Intervent Cardiol,Div Cardiol, Ottawa, ON, Canada
[3] Univ Ottawa, Inst Heart, Dept Med, Cardiac Imaging,Div Cardiol, Ottawa, ON, Canada
[4] Toronto Gen Hosp, Univ Hlth Network, Div Cardiol, Toronto, ON, Canada
[5] Univ Ottawa, Inst Heart, Cardiovasc Res Methods Ctr, Div Cardiol,Dept Med, Ottawa, ON, Canada
关键词
cardiac allograft vasculopathy; flow quantification; flow reserve; heart transplantation; intravascular ultrasound; positron emission tomography; CORONARY-ARTERY-DISEASE; MYOCARDIAL BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; HEART-TRANSPLANT RECIPIENTS; INTRAVASCULAR ULTRASOUND; INTERNATIONAL SOCIETY; ENDOTHELIAL DYSFUNCTION; INVASIVE ASSESSMENT; RESERVE; PREDICTS;
D O I
10.1016/j.jacc.2018.01.062
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Cardiac allograft vasculopathy (CAV) is a leading cause of graft failure and death after heart transplantation. Absolute myocardial blood flow (MBF) quantification using rubidium 82 (Rb-82) positron emission tomography (PET) could enable evaluation of diagnostically challenging diffuse epicardial and microvascular disease in CAV. OBJECTIVES The authors aimed to evaluate Rb-82 PET detection of CAV. METHODS Consecutive transplant recipients undergoing coronary angiography were prospectively evaluated with PET, multivessel intravascular ultrasound (IVUS), and intracoronary hemodynamics. CAV was defined as International Society of Heart and Lung Transplantation CAV(1-3) on angiography and maximal intimal thickness >= 0.5 mm on IVUS. RESULTS Forty patients (mean age 56 years, 4.8 years post-transplant) completed evaluation. CAV was detected in 32 patients (80%) by IVUS and 14 (35%) by angiography. PET correlated significantly with invasive coronary flow indices: r = 0.29, rate-pressure product-adjusted myocardial flow reserve (cMFR) versus coronary flow reserve; r = 0.28, relative flow reserve versus fractional flow reserve; and r = 0.37, coronary vascular resistance (CVR) versus index of microcirculatory resistance. Patients with CAV or microvascular dysfunction had reduced cMFR and stress MBF and increased CVR. Receiver operator characteristic curves demonstrated good accuracy of PET for CAV on IVUS (area under the curve 0.77 to 0.81) and optimal diagnostic cutoffs of cMFR < 2.9, stress MBF < 2.3, and CVR > 55. Combined PET assessment for CAV yielded excellent > 93% sensitivity (> 65% specificity) for 1 abnormal parameter and > 96% specificity (> 55% sensitivity) for 2 abnormal parameters. CONCLUSIONS Rb-82 PET flow quantification has high diagnostic accuracy for CAV, with potential for noninvasive evaluation after heart transplantation. (c) 2018 by the American College of Cardiology Foundation.
引用
收藏
页码:1444 / 1456
页数:13
相关论文
共 45 条
[1]   Lack of Relationship Between Microvascular and Macrovascular Disease in Heart Transplant Recipients [J].
Abu-Qaoud, Mohamed S. ;
Stoletniy, Liset N. ;
Chen, David ;
Kerstetter, Justin ;
Kuhn, Michael ;
Pai, Ramdas G. .
TRANSPLANTATION, 2012, 94 (09) :965-970
[2]   Relationship between coronary function by positron emission tomography and temporal changes in morphology by intravascular ultrasound (IVUS) in transplant recipients [J].
Allen-Auerbach, M ;
Schöder, H ;
Johnson, J ;
Kofoed, K ;
Einhorn, K ;
Phelps, ME ;
Kobashigawa, J ;
Czernin, J .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1999, 18 (03) :211-219
[3]   INFLUENCE OF INTIMAL THICKENING ON CORONARY BLOOD-FLOW RESPONSES IN ORTHOTOPIC HEART-TRANSPLANT RECIPIENTS - A COMBINED INTRAVASCULAR DOPPLER AND ULTRASOUND IMAGING STUDY [J].
CARACCIOLO, EA ;
WOLFORD, TL ;
UNDERWOOD, RD ;
DONOHUE, TJ ;
BACH, RG ;
MILLER, LW ;
KERN, MJ .
CIRCULATION, 1995, 92 (09) :182-190
[4]   MYOCARDIAL BLOOD-FLOW AT REST AND DURING PHARMACOLOGICAL VASODILATION IN CARDIAC TRANSPLANTS DURING AND AFTER SUCCESSFUL TREATMENT OF REJECTION [J].
CHAN, SY ;
KOBASHIGAWA, J ;
STEVENSON, LW ;
BROWNFIELD, E ;
BRUNKEN, RC ;
SCHELBERT, HR .
CIRCULATION, 1994, 90 (01) :204-212
[5]   Coronary flow reserve and relative flow reserve measured by N-13 ammonia PET for characterization of coronary artery disease [J].
Cho, Sang-Geon ;
Park, Ki Seong ;
Kim, Jahae ;
Kang, Sae-Ryung ;
Song, Ho-Chun ;
Kim, Ju Han ;
Cho, Jae Yeong ;
Hong, Young Joon ;
Jabin, Zeenat ;
Park, Hee Jeong ;
Jeong, Geum-Cheol ;
Kwon, Seong Young ;
Paeng, Jin Chul ;
Kim, Hyeon Sik ;
Min, Jung-Joon ;
Garcia, Ernest V. ;
Bom, Henry Hee-Seung .
ANNALS OF NUCLEAR MEDICINE, 2017, 31 (02) :144-152
[6]   The International Society of Heart and Lung Transplantation Guidelines for the care of heart transplant recipients [J].
Costanzo, Maria Rosa ;
Dipchand, Anne ;
Starling, Randall ;
Anderson, Allen ;
Chan, Michael ;
Desai, Shashank ;
Fedson, Savitri ;
Fisher, Patrick ;
Gonzales-Stawinski, Gonzalo ;
Martinelli, Luigi ;
McGiffin, David ;
Parisi, Francesco ;
Smith, Jon ;
Taylor, David ;
Meiser, Bruno ;
Webber, Steven ;
Baran, David ;
Carboni, Michael ;
Dengler, Thomas ;
Feldman, David ;
Frigerio, Maria ;
Kfoury, Abdallah ;
Kim, Daniel ;
Kobashigawa, Jon ;
Shullo, Michael ;
Stehlik, Josef ;
Teuteberg, Jeffrey ;
Uber, Patricia ;
Zuckermann, Andreas ;
Hunt, Sharon ;
Burch, Michael ;
Bhat, Geetha ;
Canter, Charles ;
Chinnock, Richard ;
Crespo-Leiro, Marisa ;
Delgado, Reynolds ;
Dobbels, Fabienne ;
Grady, Kathleen ;
Kao, W. ;
Lamour, Jaqueline ;
Parry, Gareth ;
Patel, Jignesh ;
Pini, Daniela ;
Pinney, Sean ;
Towbin, Jeffrey ;
Wolfel, Gene ;
Delgado, Diego ;
Eisen, Howard ;
Goldberg, Lee ;
Hosenpud, Jeff .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (08) :914-956
[7]  
Costanzo MR, 1998, J HEART LUNG TRANSPL, V17, P744
[8]   Early endothelial dysfunction predicts the development of transplant coronary artery disease at 1 year posttransplant [J].
Davis, SF ;
Yeung, AC ;
Meredith, IT ;
Charbonneau, F ;
Ganz, P ;
Selwyn, AP ;
Anderson, TJ .
CIRCULATION, 1996, 93 (03) :457-462
[9]   Coronary thermodilution to assess flow reserve - Experimental validation [J].
De Bruyne, B ;
Pijls, NHJ ;
Smith, L ;
Wievegg, M ;
Heyndrickx, GR .
CIRCULATION, 2001, 104 (17) :2003-2006
[10]   Simultaneous assessment of fractional and coronary flow reserves in cardiac transplant recipients - Physiologic investigation for transplant arteriopathy (PITA study) [J].
Fearon, WF ;
Nakamura, M ;
Lee, DP ;
Rezaee, M ;
Vagelos, RH ;
Hunt, SA ;
Fitzgerald, PJ ;
Yock, PG ;
Yeung, AC .
CIRCULATION, 2003, 108 (13) :1605-1610