Modular, cost-effective, and portable capillary gradient liquid chromatography system for on-site analysis

被引:28
|
作者
Coates, Lewellwyn J. [1 ,3 ]
Lam, Shing C. [1 ,2 ]
Gooley, Andrew A. [1 ,3 ]
Haddad, Paul R. [1 ,2 ]
Paull, Brett [1 ,2 ]
Wirth, Hans-Jurgen [1 ,3 ]
机构
[1] Univ Tasmania, ARC Ctr Portable Analyt Technol ASTech, Sch Nat Sci, Private Bag 75, Hobart, Tas 7000, Australia
[2] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Sch Nat Sci, Private Bag 75, Hobart, Tas 7000, Australia
[3] Trajan Sci & Med, 7 Argent Pl, Ringwood, Vic 3134, Australia
基金
澳大利亚研究理事会;
关键词
Miniature; Modular; Portable; HPLC; Syringe pump; Gradient; Capillary column; ABSORBENCY DETECTOR; PLATFORM; HPLC;
D O I
10.1016/j.chroma.2020.461374
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work demonstrates the development of a compact, modular, cost-effective separation system configured to address a specific separation problem. The principles of the separation are based on gradient capillary liquid chromatography where the system consists of precision stepper motor-driven portable syringe pumps with interchangeable glass syringes (100 mu L to 1000 mu L). Excellent flow-rate precision of <= 1% RSD was achieved with typical flow-rates ranging from 1 mu L/min to 100 mu L/min, which was ideal for capillary columns. A variable external loop volume and electrically actuated miniature injection valve was used for sample introduction. Detection was based upon a commercial Z-type UV absorbance flow-cell housed within a custom-built cooling enclosure (40 mm x 40 mm) which also contained a UV-LED light-source and a photodiode. System and chromatographic performance was evaluated using linear gradient elution, with day to day repeatability of <1.5% RSD (n = 6) for peak area, and < 0.4% RSD (n = 6) for retention time, for the separation of a 5 component mixture using a 50 mm x 530 pm ID C-18 3 mu m particle capillary column. The system can run any commercial or in-house packed columns from 50 mm to 100 mm length with IDs ranging from 200 to 700 mu m. The developed portable system was operated using custom-built windows-based chromatography software, complete with data acquisition and system control. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Development of cost-effective fabrication process for on-site methamphetamine detection by adsorbable SERS substrate
    Maneejark, Kroerit
    Sangwaranatee, Narong
    Chamchoi, Noppadon
    Kulnides, Narong
    Somboonsaksri, Pacharamon
    Limwichean, Saksorn
    Pogfay, Tawee
    Kalasung, Sukon
    Eiamchai, Pitak
    Patthanasettakul, Viyapol
    Limsuwan, Nutthamon
    Triamnak, Narit
    Nuntawong, Noppadon
    Horprathum, Mati
    OPTICAL MATERIALS, 2022, 124
  • [22] When Is Rapid On-Site Evaluation Cost-Effective for Fine-Needle Aspiration Biopsy?
    Schmidt, Robert L.
    Walker, Brandon S.
    Cohen, Michael B.
    PLOS ONE, 2015, 10 (08):
  • [23] A Cost-Effective Nucleic Acid Detection System Using a Portable Microscopic Device
    Yu, Chengzhuang
    Li, Shanshan
    Wei, Chunyang
    Dai, Shijie
    Liang, Xinyi
    Li, Junwei
    MICROMACHINES, 2022, 13 (06)
  • [24] Portable MiniDisc recorder as a cost-effective system to record electrophysiological spike trains
    Mojet, MH
    JOURNAL OF PHYSIOLOGY-LONDON, 2000, 526 : 2P - 2P
  • [25] Water recovery and on-site reuse of laundry wastewater by a facile and cost-effective system: Combined biological and advanced oxidation process
    Benis, Khaled Zoroufchi
    Behnami, Ali
    Aghayani, Ehsan
    Farabi, Somayeh
    Pourakbar, Mojtaba
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 789
  • [26] GRADIENT ELUTION SYSTEM FOR PACKED CAPILLARY COLUMN LIQUID-CHROMATOGRAPHY
    ANDREOLINI, F
    TRISCIANI, A
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (02) : 54 - 60
  • [27] Portable capillary electrophoresis-system for on-site food analysis with lab-on-a-chip based contactless conductivity detection
    Gaertner, Claudia
    Sewart, Rene
    Klemm, Richard
    Becker, Holger
    SENSING TECHNOLOGIES FOR GLOBAL HEALTH, MILITARY MEDICINE, AND ENVIRONMENTAL MONITORING IV, 2014, 9112
  • [28] A modular cost-effective mobile robot navigation system using RFID technology
    Gueaieb, Wail
    Miah, Md. Suruz
    Journal of Communications, 2009, 4 (02): : 89 - 95
  • [29] On-Site assessment of corn silage biochemical methane potential using a cost-effective NIR device
    Tangorra, Francesco
    Tugnolo, Alessio
    Schmilovitch, Ze 'ev
    Calcante, Aldo
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2024, 222
  • [30] Neck lump clinics: is on-site assessment of fine needle aspirate diagnostic adequacy cost-effective?
    Burgess, C.
    Dias, L.
    Maughan, E.
    Moorthy, R.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2013, 127 (11): : 1122 - 1126