Biomechanical Analysis of Suture Bridge Fixation for Tibial Eminence Fractures

被引:59
作者
Sawyer, Gregory A. [1 ]
Anderson, Brett C. [1 ]
Paller, David [1 ]
Schiller, Jonathan [1 ]
Eberson, Craig P. [1 ]
Hulstyn, Michael [1 ]
机构
[1] Rhode Isl Hosp, Brown Med Sch, Dept Orthopaed Surg, Providence, RI 02903 USA
关键词
AVULSION FRACTURE; INTERCONDYLAR EMINENCE; ARTHROSCOPIC FIXATION; CANNULATED SCREW; REPAIR; SPINE; BONE;
D O I
10.1016/j.arthro.2012.02.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To perform a biomechanical analysis of suture bridge fixation for tibial eminence fractures using PushLock anchors (Arthrex, Naples, FL) and compare it with traditional suture fixation and screw fixation. Methods: This study used 24 porcine knees, divided into 3 comparison fixation groups: PushLock suture bridge fixation, screw fixation, and suture fixation. Each knee was dissected of all soft tissue, leaving only the anterior cruciate ligament. A tibial eminence fracture was created with disruption of the posterior hinge, and each knee was fixed with a randomly assigned fixation technique. After fixation, each knee underwent 2 phases of biomechanical testing. The initial cyclic dynamic phase assessed the displacement change after 200 cycles (in millimeters) and initial stiffness (in Newtons per millimeter) of the fixation construct. After completion of dynamic testing, each specimen underwent a single tensile failure test load to assess ultimate failure load (in Newtons) and displacement (in millimeters) to ultimate failure. Results: There was a significant difference for the load-to-failure outcome variable among treatment groups (P = .004 by analysis of variance, 1 - beta = 0.851). Mean ultimate failure load borne by the PushLock fixation group was statistically significantly higher in comparison with the screw (P = .007) and suture (P = .017) fixation groups. For the cyclical testing, the primary outcome variable of displacement change after 200 loading cycles failed to show a significant difference among the 3 groups (P = .412). Conclusions: Suture bridge fixation with PushLock anchors is a new and effective surgical technique for the treatment of displaced tibial eminence fractures. By use of a high-bone density animal model, our results suggest that this suture bridge construct provides superior fixation with regard to ultimate failure load compared with standard screw fixation and suture fixation.
引用
收藏
页码:1533 / 1539
页数:7
相关论文
共 24 条
  • [21] Arthroscopic Fixation of Displaced Tibial Eminence Fractures: A New Growth Plate-Sparing Method
    Vega, Jorge R.
    Irribarra, Luis A.
    Baar, Alejandro K.
    Iniguez, Magaly
    Salgado, Martin
    Gana, Natalia
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (11) : 1239 - 1243
  • [22] Modified arthroscopic suture fixation of displaced tibial eminence fractures using a suture loop transporter
    Yip, DKH
    Wong, JWK
    Chien, EP
    Chan, CF
    [J]. ARTHROSCOPY, 2001, 17 (01): : 101 - 106
  • [23] AVULSION FRACTURE OF TIBIAL EMINENCE - TREATMENT BY OPEN REDUCTION AND PINNING
    ZARICZNYJ, B
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (08) : 1111 - 1114
  • [24] Arthroscopic treatment of nonunited anterior cruciate ligament tibial avulsion fracture with figure-of-8 suture fixation technique
    Zhao, Jinzhong
    Huangfu, Xiaoqiao
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (04) : 405 - 410