A Novel Device for Deep-Inspiration Breath Hold (DIBH): Results from a Single-Institution Phase 2 Clinical Trial for Patients with Left-Sided Breast Cancer

被引:1
|
作者
Romera-Martinez, Ingrid [1 ]
Munoz-Montplet, Carles [1 ,2 ]
Jurado-Bruggeman, Diego [1 ]
Onses-Segarra, Albert [1 ]
Fuentes-Raspall, Rafael [2 ,3 ]
Buxo, Maria [4 ]
Vilanova, Joan C. [2 ,5 ]
机构
[1] Univ Girona, Med Phys & Radiat Protect Dept, Inst Catala Oncol, Girona, Spain
[2] Univ Girona, Dept Med Sci, Girona, Spain
[3] Inst Catala Oncol, Radiat Oncol Dept, Girona, Spain
[4] Girona Biomed Res Inst, Parc Hosp Marti I Julia, Salt, Spain
[5] Inst Diagnost Imatge, Dept Radiol, Clin Girona, Girona, Spain
关键词
UK HEARTSPARE; RADIOTHERAPY; RADIATION; IRRADIATION; REDUCTION; TARGET; RECOMMENDATIONS; EXPERIENCE; EXPOSURE; SOCIETY;
D O I
10.1016/j.prro.2020.02.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To validate a novel device developed at our institution for deep inspiration breath hold (DIBH) within a phase 2 clinical trial for left-sided breast cancer and to evaluate the dosimetric benefits of its use. Methods and Materials: The device uses an external mechanical reference for guiding the patient to the desired breath level and gives acoustic and visual feedback to the patient and the radiation therapists, respectively. A phase 2 clinical trial was performed for its validation. The thoracic amplitude was used as a surrogate of the inspiration level. The stability, repeatability, reproducibility, and reliability of DIBH using the device were analyzed. The dosimetric parameters of the heart, the left anterior descending coronary artery, the ipsilateral lung, the contralateral breast, and the target coverage using free breathing and DIBH were compared. Results: Thirty-eight patients were included in the analysis. The maximum population value of stability and repeatability were 1.7 mm and 3.3 mm, respectively. The reproducibility mean value was 1.7 mm, and population systematic and random errors were 0.3 mm and 0.9 mm, respectively. The reliability was 98.9%. Statistically significant dose reductions were found for the heart, the left anterior descending coronary artery, and the ipsilateral lung dosimetric parameters in DIBH, without losing dose coverage to the planning target volumes. Conclusions: The validation of the device within the phase 2 clinical trial demonstrates that it offers reliable, stable, repeatable, and reproducible breast cancer treatments in DIBH with its dosimetric benefits. (C) 2020 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E290 / E297
页数:8
相关论文
共 50 条
  • [31] Cardiac sparing characteristics of internal mammary chain radiotherapy using deep inspiration breath hold for left-sided breast cancer
    Nguyen, Macklin H.
    Lavilla, Myra
    Kim, Janice N.
    Fang, L. Christine
    RADIATION ONCOLOGY, 2018, 13
  • [32] Deep inspiration breath-hold technique for left-sided breast cancer: An analysis of predictors for organ-at-risk sparing
    Register, Steven
    Takita, Cristiane
    Reis, Isildinha
    Zhao, Wei
    Amestoy, William
    Wright, Jean
    MEDICAL DOSIMETRY, 2015, 40 (01) : 89 - 95
  • [33] Dosimetry and Feasibility Studies of Volumetric Modulated Arc Therapy With Deep Inspiration Breath-Hold Using Optical Surface Management System for Left-Sided Breast Cancer Patients
    Zhang, Wei
    Li, Ruisheng
    You, Dong
    Su, Yi
    Dong, Wei
    Ma, Zhao
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [34] Estimation of heart-position variability in 3D-surface-image-guided deep-inspiration breath-hold radiation therapy for left-sided breast cancer
    Alderliesten, Tanja
    Betgen, Anja
    Elkhuizen, Paula H. M.
    van Vliet-Vroegindeweij, Corine
    Remeijer, Peter
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 442 - 447
  • [35] Investigation of cardiac and pulmonar doses in patients with left sided breast cancer treated by radiotherapy with deep inspiration breath hold technique
    Parlar, S.
    Var, G.
    Cosar, R.
    Dogan, M.
    Ozguven, Y.
    Nurlu, D.
    CemUzal, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (02): : 369 - 375
  • [36] Left-sided breast cancer locoregional radiation therapy with rotational intensity-modulated irradiation and deep inspiration breath hold: Dosimetric comparison
    Fessart, E.
    Crop, F.
    Tresch, E.
    Mirabel, X.
    Lartigau, E.
    Pasquier, D.
    CANCER RADIOTHERAPIE, 2019, 23 (02): : 92 - 97
  • [37] Resource requirements and reduction in cardiac mortality from deep inspiration breath hold (DIBH) radiation therapy for left sided breast cancer patients: A prospective service development analysis
    Chatterjee, Sanjay
    Chakraborty, Santam
    Moses, Arunsingh
    Nallathambi, Chandran
    Mahata, Anurupa
    Mandat, Samar
    Achari, Rimpa Basu
    Mattick, Indranit
    Shrimati, Raj Kumar
    Bhattacharyya, Tapesh
    Agrawal, Sanjit
    Ghosh, Joydeep
    Ahmed, Rosina
    PRACTICAL RADIATION ONCOLOGY, 2018, 8 (06) : 382 - 387
  • [38] Deep inspiration breath-hold intensity modulated radiation therapy in a large clinical series of 239 left-sided breast cancer patients: a dosimetric analysis of organs at risk doses and clinical feasibility from a single center experience
    Testolin, Alessandro
    Ciccarelli, Stefano
    Dano, Giulia Vi
    Avitabile, Rossella
    Dust, Francesca
    Alongi, Filippo
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1101)
  • [39] Deep inspiration breath-hold for patients with left-sided breast cancer - A one-fits-all approach? A prospective analysis of patient selection using dosimetrical and practical aspects
    Schroeder, Christina
    Kirschke, Sebastian
    Blank, Eyck
    Rohrberg, Sophia
    Forster, Robert
    Buchali, Andre
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1135)
  • [40] Cardiac exposure in left-sided breast cancer patients undergoing deep inspiratory breath hold radiation therapy
    Zhu, Huijun
    Sun, Huiwen
    Zhang, Jiaming
    Xie, Yiting
    Jassem, Jacek
    Franco, Pierfrancesco
    Sun, Weiliang
    Liu, Wenqi
    Yue, Haiying
    GLAND SURGERY, 2023, 12 (05) : 677 - 686