Incidental detection of a retained left atrial catheter via intraoperative transesophageal echocardiography in a patient undergoing tricuspid valve replacement A case report

被引:1
作者
Pyeon, Taehee [1 ]
Bae, Hong-Beom [1 ,2 ]
Choi, Jeong Il [1 ,2 ]
Kim, Taeyeong [1 ]
Kim, Joungmin [1 ,2 ]
机构
[1] Chonnam Univ Hosp, Dept Anesthesiol & Pain Med, Gwangju, South Korea
[2] Chonnam Natl Univ, Dept Anesthesiol & Pain Med, Gwangju, South Korea
关键词
cardiac foreign body; indwelling catheter; left atrial catheter; transesophageal echocardiography; MANAGEMENT; HEART;
D O I
10.1097/MD.0000000000020058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rationale: A cardiac foreign body can cause thrombosis or infection, but sometimes it may not cause any symptoms in a patient. The diagnosis is mainly performed using a radiological examination. Especially, ultrasound is useful not only for detecting the foreign body but also for hemodynamic findings. However, the disadvantage of ultrasound is that it cannot be used where shadows are generated because of poor permeability. The transesophageal echocardiography (TEE) is superior to transthoracic echocardiography (TTE) for identifying posterior cardiac structures because the probe is located in the esophagus behind the heart. Here, we report on the incidental finding of a foreign body in the left atrium through TEE during cardiac surgery. It did not cause any symptoms or signs for 20 years. Patient concerns: A 75-year-old female patient with severe tricuspid regurgitation underwent tricuspid valve replacement (TVR) under general anesthesia. She had a history of mitral valve replacement (MVR) and tricuspid annuloplasty surgery 20 years ago. Diagnosis: A hyper-echoic floating intracardiac foreign body was observed in the left atrium during TEE examination. It was not detected in the preoperative imaging studies such as X-ray, computed tomography, TTE. Interventions: The cardiac foreign body found using TEE was visually confirmed through an incision in the left atrium. A long and thin foreign body was located in the right upper pulmonary vein to the left atrium, which was considered to be a left atrial catheter used during the MVR surgery performed 20 years ago. After removing the foreign body, the planned TVR operation proceeded. Outcomes: After removing the intracardiac foreign body and TVR, the patient was admitted into the intensive care unit followed by the general ward as planned, and discharged without any complications. Lessons: TEE was very useful for diagnosing a foreign body in the posterior part of the heart. TEE performed during the perioperative period should be performed beyond the level of re-confirming the findings of TEE performed prior to surgery. If a retained catheter is detected, it may be appropriate to remove it considering the risk of complications.
引用
收藏
页数:4
相关论文
共 16 条
[1]   Penetrating Injury of the Heart From a Chronically Migrating Foreign Body [J].
Al-Jalahma, Jawaher ;
Al-Hakami, Wejdan ;
Musayab, Yazan ;
Ismail, Tariq ;
Nair, Rajasekharan ;
Bin Thani, Khalid .
ANNALS OF THORACIC SURGERY, 2016, 102 (03) :E191-E192
[2]   Recurrent Bacteremia After Heart Transplantation Due to Abandoned Lead Fragment in an Anonymous Vein-A Case Report [J].
Burger, H. ;
Ziegelhoeffer, T. ;
Schoenburg, M. ;
Richter, M. .
TRANSPLANTATION PROCEEDINGS, 2018, 50 (10) :4071-4074
[3]   Posttraumatic and iatrogenic foreign bodies in the heart: Report of fourteen cases and review of the literature [J].
Dato, GMA ;
Arslanian, A ;
Di Marzio, P ;
Filosso, PL ;
Ruffini, E .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (02) :408-414
[4]   Branch retinal artery occlusion from a retained left aerial catheter 21 years after operation [J].
Drummond-Webb, JJ ;
Bokesch, PM ;
Ebeid, MR ;
Murphy, DJ ;
Sarris, GE ;
Mee, RBB .
ANNALS OF THORACIC SURGERY, 1998, 65 (01) :254-255
[5]   A wandering pacemaker lead [J].
Ebert, Alberto Genovesi ;
Paperini, Luca ;
Glauber, Mattia ;
Solinas, Antonio ;
Galli, Michele .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2007, 8 (05) :392-393
[6]  
El-Heis S, 2013, BMJ CASE REP, P2013
[7]  
Hynes Mark S, 2005, J Am Soc Echocardiogr, V18, P1423
[8]   THE LEFT ATRIAL CATHETER - ITS USES AND COMPLICATIONS [J].
LEITMAN, BS ;
NAIDICH, DP ;
MCGUINNESS, G ;
MCCAULEY, DI .
RADIOLOGY, 1992, 185 (02) :611-612
[9]   Foreign Bodies in the Heart [J].
Leitman, Marina ;
Vered, Zvi .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (02) :365-371
[10]   Cardiac Perforation by Migrated Fractured Strut of Inferior Vena Cava Filter Mimicking Acute Coronary Syndrome [J].
Piercecchi, Chris W. ;
Vasquez, Julio C. ;
Kaplan, Stephen J. ;
Hoffman, Jordan ;
Puskas, John D. ;
Delarosa, Jacob .
HEART LUNG AND CIRCULATION, 2017, 26 (02) :E11-E13