Selective Electrochemical Sensing of Glycated Hemoglobin (HbA1c) on Thiophene-3-Boronic Acid Self-Assembled Monolayer Covered Gold Electrodes

被引:90
作者
Park, Jin-Young [1 ,2 ]
Chang, Byoung-Yong [1 ,2 ]
Nam, Hakhyun [3 ]
Park, Su-Moon [1 ,2 ]
机构
[1] Pohang Univ Sci & Technol, Dept Chem, Pohang 790784, Gyeongbuk, South Korea
[2] Pohang Univ Sci & Technol, Ctr Integrated Mol Syst, Pohang 790784, Gyeongbuk, South Korea
[3] Kwangwoon Univ, Dept Chem, Seoul 139701, South Korea
关键词
D O I
10.1021/ac8010439
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a novel concept of sensing glycated hemoglobin, HbA(1c), which is now the most important index for a long-term average blood glucose level, by first selectively immobilizing it on the thiophene-3-boronic acid (T3BA) self-assembled monolayer (SAM)-covered gold electrode by a selective chemical reaction with boronic acid. HbA(1c) thus immobilized is then detected by the label-free electrochemical impedance spectroscopic (EIS) measurements with a redox probe, an equimolar mixture of K3Fe(CN)(6) and K4Fe(CN)(6), present. The rate of charge transfer between the electrode and the redox probe is shown to be modulated by the amount of HbA(1c) in the matrix hemoglobin solution due to the blocking effect caused by the binding of HbA(1c) with boronic acid. Both the formation of a well-defined T3BA-SAM on the gold surface and the chemical binding of its boronic acid with HbA(1c), in solution were confirmed by quartz crystal microbalance, atomic force microscopy, and EIS experiments.
引用
收藏
页码:8035 / 8044
页数:10
相关论文
共 43 条
[1]   Chemiluminescent acridinium-9-carboxamide boronic acid probes: Application to a homogenous glycated hemoglobin assay [J].
Adamczyk, M ;
Chen, YY ;
Johnson, DD ;
Mattingly, PG ;
Moore, JA ;
Pan, Y ;
Reddy, RE .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2006, 16 (05) :1324-1328
[2]  
Bakkeren DL, 1999, CLIN CHEM, V45, pA71
[3]   Measurement of glycated haemoglobin in whole blood by a novel fluorescence quenching assay [J].
Blincko, S ;
Anzetse, J ;
Edwards, R .
ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 :492-497
[4]  
Blincko S, 1998, CLIN CHEM, V44, P1302
[5]   A reliable non-separation fluorescence quenching assay for total glycated serum protein: a simple alternative to nitroblue tetrazolium reduction [J].
Blincko, S ;
Colbert, D ;
John, WG ;
Edwards, R .
ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 :372-379
[6]   Integrated description of electrode/electrolyte interfaces based on equivalent circuits and its verification using impedance measurements [J].
Chang, BY ;
Park, SM .
ANALYTICAL CHEMISTRY, 2006, 78 (04) :1052-1060
[7]   Fourier transform analysis of chronoamperometric currents obtained during staircase voltammetric experiments [J].
Chang, Byoung-Yong ;
Park, Su-Moon .
ANALYTICAL CHEMISTRY, 2007, 79 (13) :4892-4899
[8]   Determination of electron transfer kinetic parameters by Fourier transform electrochemical impedance spectroscopic analysis [J].
Chang, Byoung-Yong ;
Hong, Sung-Young ;
Yoo, Jung-Suk ;
Park, Su-Moon .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (39) :19386-19392
[9]  
Chen D, 1998, CLIN CHEM, V44, P1296
[10]   Electrochemistry of conductive polymers 39. Contacts between conducting polymers and noble metal nanoparticles studied by current-sensing atomic force microscopy [J].
Cho, Shin Hyo ;
Park, Su-Moon .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (51) :25656-25664