Detecting Atrial Fibrillation and Atrial Flutter in Daily Life Using Photoplethysmography Data

被引:41
作者
Eerikainen, Linda M. [1 ,2 ]
Bonomi, Alberto G. [2 ]
Schipper, Fons [2 ]
Dekker, Lukas R. C. [1 ,3 ]
de Morree, Helma M. [2 ]
Vullings, Rik [1 ]
Aarts, Ronald M. [1 ,2 ]
机构
[1] Eindhoven Univ Technol, Dept Elect Engn, NL-5612 AE Eindhoven, Netherlands
[2] Philips Res, NL-5656 AE Eindhoven, Netherlands
[3] Catharina Hosp, NL-5623 EJ Eindhoven, Netherlands
关键词
Rhythm; Heart rate; Electrocardiography; Monitoring; Training; Accelerometers; Computational modeling; Photoplethysmography; Accelerometer; Atrial Fibrillation (AF); Atrial Flutter; Random Forest; REDUCTION; SELECTION; RISK;
D O I
10.1109/JBHI.2019.2950574
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: Photoplethysmography (PPG) enables unobtrusive heart rate monitoring, which can be used in wrist-worn applications. Its potential for detecting atrial fibrillation (AF) has been recently presented. Besides AF, another cardiac arrhythmia increasing stroke risk and requiring treatment is atrial flutter (AFL). Currently, the knowledge about AFL detection with PPG is limited. The objective of our study was to develop a model that classifies AF, AFL, and sinus rhythm with or without premature beats from PPG and acceleration data measured at the wrist in daily life. Methods: A dataset of 40 patients was collected by measuring PPG and accelerometer data, as well as electrocardiogram as a reference, during 24-hour monitoring. The dataset was split into 75%-25% for training and testing a Random Forest (RF) model, which combines features from PPG, inter-pulse intervals (IPI), and accelerometer data, to classify AF, AFL, and other rhythms. The performance was compared to an AF detection algorithm combining traditional IPI features for determining the robustness of the accuracy in presence of AFL. Results: The RF model classified AF/AFL/other with sensitivity and specificity of 97.6/84.5/98.1% and 98.2/99.7/92.8%, respectively. The results with the IPI-based AF classifier showed that the majority of false detections were caused by AFL. Conclusion: The PPG signal contains information to classify AFL in the presence of AF, sinus rhythm, or sinus rhythm with premature contractions. Significance: PPG could indicate presence of AFL, not only AF.
引用
收藏
页码:1610 / 1618
页数:9
相关论文
共 50 条
  • [1] Aliamiri Alireza, 2018, 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), P442, DOI 10.1109/BHI.2018.8333463
  • [2] Photoplethysmography and its application in clinical physiological measurement
    Allen, John
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) : R1 - R39
  • [3] [Anonymous], 2018, ARXIV180710707
  • [4] Besleaga T., 2018, P COMP CARD C, V45, P1
  • [5] Atrial Fibrillation, Stroke Risk, and Warfarin Therapy Revisited A Population-Based Study
    Bjorck, Staffan
    Palaszewski, Bo
    Friberg, Leif
    Bergfeldt, Lennart
    [J]. STROKE, 2013, 44 (11) : 3103 - 3108
  • [6] Atrial Fibrillation Detection Using a Novel Cardiac Ambulatory Monitor Based on Photo-Plethysmography at the Wrist
    Bonomi, Alberto G.
    Schipper, Fons
    Eerikainen, Linda M.
    Margarito, Jenny
    van Dinther, Ralph
    Muesch, Guido
    de Morree, Helma M.
    Aarts, Ronald M.
    Babaeizadeh, Saeed
    McManus, David D.
    Dekker, Lukas R. C.
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (15):
  • [7] Breiman L., 2001, Mach. Learn., V45, P5
  • [8] Atrial flutter: more than just one of a kind
    Bun, Sok-Sithikun
    Latcu, Decebal Gabriel
    Marchlinski, Francis
    Saoudi, Nadir
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 (35) : 2356 - U28
  • [9] Chong J.W., 2015, IEEE T BIOMED ENG, V19, P1
  • [10] Detection of atrial fibrillation episodes using a wristband device
    Corino, Valentina D. A.
    Laureanti, Rita
    Ferranti, Lorenzo
    Scarpini, Giorgio
    Lombardi, Federico
    Mainardi, Luca T.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2017, 38 (05) : 787 - 799